New type lightning protection schemes of substation incoming lines and their simulations

被引:0
|
作者
Jin, X [1 ]
Lu, W [1 ]
Chen, SJ [1 ]
机构
[1] Shanghai Univ Elect Power, EE Dept, Shanghai 200090, Peoples R China
关键词
substation incoming lines; line ZnO arrester; over-voltage; coupling grounding wire;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Lightning failures on incoming lines have serious impact on the safety of power substation. In some mountain areas, where the lightning activity is strong and the soil resistance is high, it is difficult to have its enough efficiency in taking traditional protective measures against lightning discharges. Two new protection measures of incoming lines are proposed and analyzed in this paper: line ZnO arrester and coupling grounding wire. Rationally installed ZnO arresters will bring about both safety and economical effect on the protection of incoming lines. The coupling grounding wire is installed under the phase conductor. The electromagnetic coupling effects are improved because of coupling ground wire. The electromagnetic transient calculations are made to analyze these two measures' protective effects. According to the results of simulation, the over-voltage on the equipments is reduced significantly with the installation of line arrester. And the coupling grounding wires improve lightning protective level effectively. The computational methods are introduced and the results are compared.
引用
收藏
页码:481 / 485
页数:5
相关论文
共 50 条
  • [1] The Research of a New Type of Lightning Protection Scheme of Transmission Lines
    Yao, Jianhong
    Fu, Qiang
    Chen, Qiuying
    Liu, Jicheng
    2010 INTERNATIONAL CONFERENCE ON INFORMATION, ELECTRONIC AND COMPUTER SCIENCE, VOLS 1-3, 2010, : 191 - 194
  • [2] Probabilistic evaluation of the substation performance under incoming lightning surges
    Bedoui, Samir
    Bayadi, Abdelhafid
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 162 : 125 - 133
  • [3] Substation Lightning Protection Case Study
    Martineac, Corina
    Darab, Cosmin
    PROCEEDINGS OF 2019 8TH INTERNATIONAL CONFERENCE ON MODERN POWER SYSTEMS (MPS), 2019,
  • [4] Lightning Surge Response of a Double-Circuit Transmission Tower with Incoming Lines to a Substation through FDTD Simulation
    Takami, Jun
    Tsuboi, Toshihiro
    Yamamoto, Keisuke
    Okabe, Shigemitsu
    Baba, Yoshihiro
    Ametani, Akihiro
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (01) : 96 - 104
  • [5] Electromagnetic interference on secondary systems of substation caused by incoming lightning stroke
    Gong Xuehai
    He Jinliang
    2007 4TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY PROCEEDING: EMC 2007, 2007, : 212 - +
  • [6] New type of substation-area backup protection for intelligent substation
    Key Lab. of Power System Intelligent Dispatch and Control of Ministry of Education , Jinan 250061, China
    不详
    Dianli Xitong Baohu yu Kongzhi, 2 (32-38):
  • [7] Designing Optimum Substation Lightning Shield Protection
    Urgena, Adriano
    Elwell, Eric
    2020 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2020,
  • [8] Comprehensive Assessment of Lightning Protection Schemes for 10 kV Overhead Distribution Lines
    Cao, Jinxin
    Du, Yaping
    Ding, Yuxuan
    Qi, Ruihan
    Li, Binghao
    Chen, Mingli
    Li, Zhe
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (03) : 2326 - 2336
  • [9] Research on lightning protection engineering of traction substation in heavy lightning zone
    Zhu, Jiang
    Journal of Railway Engineering Society, 2013, 30 (01) : 92 - 99
  • [10] LIGHTNING PROTECTION OF TRANSMISSION LINES
    BURGSDOR.VV
    ELECTRICAL TECHNOLOGY, 1969, 3 : 76 - &