In-vivo evaluation of the surface roughness and morphology of enamel after bracket removal and polishing by different techniques

被引:39
|
作者
Faria-Junior, Elcio Mario [1 ]
Guiraldo, Ricardo Danil [2 ]
Berger, Sandrine Bittencourt [2 ]
Correr, Americo Bortolazzo [3 ]
Correr-Sobrinho, Lourenco [3 ]
Ruiz Contreras, Edwin Fernando [4 ]
Lopes, Murilo Baena [2 ]
机构
[1] Univ Western Sao Paulo, Sch Dent, Dept Restorat Dent, Presidente Prudente, SP, Brazil
[2] Univ North Parana, Sch Dent, Dept Restorat Dent, Londrina, Parana, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, Piracicaba, SP, Brazil
[4] Univ Estadual Londrina, Sch Dent, Dept Restorat Dent, Londrina, Parana, Brazil
关键词
SHEAR BOND STRENGTH; ORTHODONTIC BRACKETS; MICROABRASION; PERCEPTION; VITRO;
D O I
10.1016/j.ajodo.2014.10.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to evaluate the surface roughness and morphology of enamel with a surface roughness tester and scanning electron microscopy after the removal of metal brackets and polishing. Methods: Ten orthodontic patients were selected for the study. At the conclusion of orthodontic treatment, their metal brackets were removed. For each patient, teeth on one side of the mouth were randomly chosen for finishing and polishing with aluminum oxide discs (n = 10). Teeth on the other side were finished with multilaminated carbide burs (n = 10). Dental replicas (before and after tooth polishing) were obtained with epoxy resin. Three surface roughness measurements were made in different directions with an angle of 120 degrees among them, and a mean for each dental replica was calculated. The roughness data were statistically evaluated by repeated-measurements analysis of variance. Three specimens from each group were also used for scanning electron microscopy analysis. Results: After resin removal, the average roughness in the carbide bur group (0.31 mu m) was significantly greater than that in the aluminum oxide disc group (0.25 mm). Conclusions: The aluminum oxide disc polishing system resulted in less enamel roughness than did the multilaminated carbide bur system.
引用
收藏
页码:324 / 329
页数:6
相关论文
共 50 条
  • [1] Analysis of enamel surface roughness after different adhesive removal techniques for orthodontic bracket debonding
    Palmer J.A.
    Mang T.
    Tabbaa S.
    Al-Jewair T.
    Lasers in Dental Science, 2018, 2 (2) : 95 - 101
  • [2] Loss of surface enamel after bracket debonding: An in-vivo and ex-vivo evaluation
    Pont, Huib Berghauser
    Oezcan, Mutlu
    Bagis, Bora
    Ren, Yijin
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (04) : 387 - 389
  • [3] Evaluation of enamel surface after bracket debonding and adhesive removal with six different methods
    Arbutina, Adriana
    Arapovic-Savic, Marijana
    Umicevic-Davidovic, Mirjana
    Kuzmanovic-Radman, Irena
    Nedeljkovic, Nenad
    Glisic, Branislav
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2020, 148 (7-8) : 404 - 409
  • [4] Enamel surface morphology after bracket debonding
    Osorio, R
    Toledano, M
    Garcia-Godoy, F
    JOURNAL OF DENTISTRY FOR CHILDREN, 1998, 65 (05): : 313 - +
  • [5] Evaluation of Enamel Roughness in Vitro After Orthodontic Bracket Debonding Using Different Methods of Residual Adhesive Removal
    Lima Ferreira, Jose Tarcisio
    Borsatto, Maria Cristina
    Pereira Saraiva, Maria Conceicao
    Nakane Matsumoto, Mirian Aiko
    Torres, Carolina Paes
    Romano, Fabio Lourenco
    TURKISH JOURNAL OF ORTHODONTICS, 2020, 33 (01) : 43 - 51
  • [6] Evaluation of enamel surfaces after bracket debonding: An in-vivo study with scanning electron microscopy
    Bonetti, Giulio Alessandri
    Zanarini, Matteo
    Parenti, Serena Incerti
    Lattuca, Monica
    Marchionni, Silvia
    Gatto, Maria Rosaria
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (05) : 696 - 702
  • [7] Evaluation of enamel surface roughness after orthodontic bracket debonding with atomic force microscopy
    Mohebi, Shadi
    Shafiee, Hassan-Ali
    Ameli, Nazila
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 151 (03) : 521 - 527
  • [8] Surface roughness of acrylic resins after different curing and polishing techniques
    Milanezi Alves, Patricia Valeria
    Lima Filho, Roberto M. A.
    Telles, Elise
    Bolognese, Ana
    ANGLE ORTHODONTIST, 2007, 77 (03) : 528 - 531
  • [9] Enamel detachment after in vitro and in vivo bracket removal.
    Sorel, O
    Alam, R
    Chagneau, F
    Cathelineau, G
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1206 - 1206
  • [10] Enamel Surface Roughness after Lingual Bracket Debonding: An In Vitro Study
    Eichenberger, Martina
    Iliadi, Anna
    Koletsi, Despina
    Eliades, George
    Verna, Carlalberta
    Eliades, Theodore
    MATERIALS, 2019, 12 (24)