A 3D navigation template for guiding a unilateral lumbar pedicle screw with contralateral translaminar facet screw fixation: a study protocol for multicentre randomised controlled trials

被引:10
|
作者
Shao, Zhen-Xuan [1 ,2 ]
He, Wei [3 ]
He, Shao-Qi [4 ]
Lin, Sheng-Lei [5 ]
Huang, Zhe-Yu [6 ]
Tang, Hong-Chao [7 ]
Ni, Wen-Fei [1 ,2 ]
Wang, Xiang-Yang [1 ,2 ]
Wu, Ai-Min [1 ,2 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 2, Orthopaed Hosp, Dept Spine Surg, Wenzhou, Peoples R China
[2] Wenzhou Med Univ, Yuying Childrens Hosp, Med Sch 2, Zhejiang Spine Ctr, Wenzhou, Peoples R China
[3] Zhejiang Univ, Peoples Hosp Shaoxing, Dept Orthopaed, Shaoxing Hosp, Shaoxing, Peoples R China
[4] Wenzhou Med Univ, Affiliated Hosp 3, Dept Orthopaed, Peoples Hosp Ruian, Ruian, Peoples R China
[5] Wenzhou Med Univ, Dept Orthopaed, Wenzhou Ctr Hosp, Dingli Hosp, Wenzhou, Peoples R China
[6] Ningbo 6 Hosp, Dept Orthopaed, Ningbo, Zhejiang, Peoples R China
[7] Jiaxing Hosp Zhejiang Gen Corps Armed Police Forc, Dept Orthopaed, Jiaxing, Peoples R China
来源
BMJ OPEN | 2017年 / 7卷 / 07期
基金
中国国家自然科学基金;
关键词
INTERBODY FUSION; SPINAL STENOSIS; PLACEMENT; GUIDANCE; DISEASE;
D O I
10.1136/bmjopen-2017-016328
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The incidence of lumbar disc degeneration disease has increased in recent years. Lumbar interbody fusion using two unilateral pedicle screws and a translaminar facet screw fixation has advantages of minimal invasiveness and lower costs compared with the traditional methods. Moreover, a method guided by a three-dimensional (3D) navigation template may help us improve the surgical accuracy and the success rate. This is the first randomised study using a 3D navigation template to guide a unilateral lumbar pedicle screw with contralateral translaminar facet screw fixation. Methods and analysis Patients who meet the criteria of the surgery will be randomly divided into experimental groups and control groups by a computer-generated randomisation schedule. We will preoperatively design an individual 3D navigation template using CATIA software and MeditoolCreate. The following primary outcomes will be collected: screw angles compared with the optimal screw trajectories in 3D digital images, length of the wound incision, operative time, intraoperative blood loss and complications. The following secondary outcomes will be collected: visual analogue scale (VAS) for back pain, VAS for leg pain and the Oswestry Disability Index. These parameters will be evaluated on day 1 and then 3, 6, 12 and 24 months postoperatively. Ethics and dissemination The study has been reviewed and approved by the institutional ethics review board of the Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University. The results will be presented at scientific communities and peer-reviewed journals.
引用
收藏
页数:7
相关论文
共 45 条
  • [1] Innovative 3D Navigation Module for Precise Unilateral Pedicle Screw Combined with Contralateral Translaminar Facet Screw Placement in Lumbar Spine Surgery
    Chen, Xu
    Dai, Hanhao
    Luo, Jun
    Zhang, Huaizhi
    Song, Chao
    Deng, Zhibo
    Zhang, Yanyan
    Li, Xing
    Dai, Jianhui
    Xu, Jie
    ORTHOPAEDIC SURGERY, 2024, 16 (12) : 3026 - 3035
  • [2] Transforaminal lumbar interbody fusion using unilateral pedicle screw fixation plus contralateral translaminar facet screw fixation in lumbar degenerative diseases
    Fubing Liu
    Chun Jiang
    Yuanwu Cao
    Xiaoxing Jiang
    Zhenzhou Feng
    Indian Journal of Orthopaedics, 2014, 48 : 374 - 379
  • [3] Transforaminal lumbar interbody fusion using unilateral pedicle screw fixation plus contralateral translaminar facet screw fixation in lumbar degenerative diseases
    Liu, Fubing
    Jiang, Chun
    Cao, Yuanwu
    Jiang, Xiaoxing
    Feng, Zhenzhou
    INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (04) : 374 - 379
  • [4] Biomechanical study of unilateral pedicle screw combined with contralateral translaminar facet screw in transforaminal lumbar interbody fusion
    Luo, Beier
    Yan, Ming
    Huang, Jinghui
    Duan, Wei
    Huang, Zhiping
    Chen, Jianting
    Luo, Zhuojing
    Zhu, Qingan
    Li, Ming
    CLINICAL BIOMECHANICS, 2015, 30 (07) : 657 - 661
  • [5] The combined use of unilateral pedicle screw and contralateral facet joint screw fixation in transforaminal lumbar interbody fusion
    Cao, Yuanwu
    Chen, Zixian
    Jiang, Chun
    Wan, Shengcheng
    Jiang, Xiaoxing
    Feng, Zhenzhou
    EUROPEAN SPINE JOURNAL, 2015, 24 (11) : 2607 - 2613
  • [6] The combined use of unilateral pedicle screw and contralateral facet joint screw fixation in transforaminal lumbar interbody fusion
    Yuanwu Cao
    Zixian Chen
    Chun Jiang
    Shengcheng Wan
    Xiaoxing Jiang
    Zhenzhou Feng
    European Spine Journal, 2015, 24 : 2607 - 2613
  • [7] Is unilateral pedicle screw fixation as effective as bilateral pedicle screw fixation in transforaminal lumbar interbody fusion: a meta-analysis of randomized controlled trials
    Lian Xu
    Xu Lin
    Chao Wu
    Lun Tan
    European Spine Journal, 2023, 32 : 700 - 711
  • [8] Is unilateral pedicle screw fixation as effective as bilateral pedicle screw fixation in transforaminal lumbar interbody fusion: a meta-analysis of randomized controlled trials
    Xu, Lian
    Lin, Xu
    Wu, Chao
    Tan, Lun
    EUROPEAN SPINE JOURNAL, 2023, 32 (02) : 700 - 711
  • [9] Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine
    Guo, Fei
    Dai, Jianhao
    Zhang, Junxiang
    Ma, Yichuan
    Zhu, Guanghui
    Shen, Junjie
    Niu, Guoqi
    PLOS ONE, 2017, 12 (02):
  • [10] Facet Violation With Percutaneous Pedicle Screw Placement: Impact of 3D Navigation and Facet Orientation
    Cong, Ting
    Sivaganesan, Ahilan
    Mikhail, Christopher M.
    Vaishnav, Avani S.
    Dowdell, James, III
    Barbera, Joseph
    Kumagai, Hiroshi
    Markowitz, Jonathan
    Sheha, Evan
    Qureshi, Sheeraz A.
    HSS JOURNAL, 2021, 17 (03) : 281 - 288