Use of a near-infrared diode laser to activate mouse cutaneous nociceptors in vitro

被引:4
|
作者
Pribisko, Alaine L. [1 ]
Perl, Edward R. [1 ]
机构
[1] Univ N Carolina, Dept Cell & Mol Physiol, Sch Med, Chapel Hill, NC 27599 USA
关键词
980 nm diode laser; Skin-nerve preparation; Mouse; Heat-sensitive; In vitro; Nociceptor; PRIMARY AFFERENT UNITS; GLABROUS SKIN; FUNCTIONAL-PROPERTIES; NOXIOUS STIMULI; NERVE-ENDINGS; HAIRY SKIN; HEAT; MECHANORECEPTORS; TEMPERATURE; NEURONS;
D O I
10.1016/j.jneumeth.2010.10.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A skin-nerve preparation is useful for study of heat transduction mechanisms of A- and C-high threshold primary afferents (nociceptors), but the small dimension and liquid environment of the skin organ bath do not readily accommodate conventional noxious heat delivery systems. For these reasons, a 980 nm (near-infrared) diode laser was tested for activation and differentiation of cutaneous afferents. Current to the laser driver was varied. Exposure time and area, angle of approach, and stand-off distance from the bath solution surface were held constant. Seventy-eight fibers were classified by: conduction velocity, mechanical threshold, and responsiveness to laser radiation. A subset of the sampled fibers was also tested for sensitivity to convective heat. Most C (30/43) and a few A (6/25) nociceptors responded to laser irradiation. All low mechanical threshold primary afferents (10/10) were unresponsive to laser irradiation. Laser-sensitive fibers responded to convective heat, whereas laser-insensitive fibers did not. Laser-induced responses were consistent with literature reports of responses to traditional heat stimulation. Laser stimulation proved to be a rapid, unobtrusive method for reproducible heat stimulation of primary afferents of the mouse skin-nerve preparation. It is effective for defining subpopulations of primary afferent fibers and holds promise as a tool for gauging modification of C-fiber activity. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 50 条
  • [1] NEAR-INFRARED LASER DIODE SPECTROSCOPY
    PATONAY, G
    UNGER, E
    HUFF, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 139 - ANYL
  • [2] Near-infrared diode laser air monitoring
    Holdsworth, RJ
    Martin, PA
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 1998, 52 (1-2) : 141 - 148
  • [3] Use of an FTIR Spectrometer to Characterize the Spectral Output of a Near-Infrared Diode Laser
    Spragg, Richard
    AMERICAN LABORATORY, 2011, 43 (09) : 16 - 16
  • [4] NEAR-INFRARED LASER DIODE INTRACAVITY ABSORPTION SPECTROMETRY
    UNGER, E
    PATONAY, G
    ANALYTICAL CHEMISTRY, 1989, 61 (13) : 1425 - 1427
  • [5] Near-infrared diode laser spectroscopy of the HCSi radical
    Fujitake, M
    Echizenya, R
    Shirai, T
    Kurita, S
    Ohashi, N
    JOURNAL OF MOLECULAR SPECTROSCOPY, 2004, 223 (02) : 113 - 119
  • [6] NEAR-INFRARED DIODE-LASER AIRBORNE HYGROMETER
    SILVER, JA
    HOVDE, DC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (05): : 1691 - 1694
  • [7] Near-infrared diode laser spectroscopy of free radicals
    Ohashi, N
    Fujitake, M
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2004, 60 (14) : 3277 - 3284
  • [8] Ammonia detection by use of near-infrared diode-laser-based overtone spectroscopy
    Claps, Ricardo
    Englich, Florian V.
    Leleux, Darrin P.
    Richter, Dirk
    Tittel, Frank K.
    Curl, Robert F.
    Applied Optics, 2001, 40 (24): : 4387 - 4394
  • [9] Ammonia detection by use of near-infrared diode-laser-based overtone spectroscopy
    Claps, R
    Englich, FV
    Leleux, DP
    Richter, D
    Tittel, FK
    Curl, RF
    APPLIED OPTICS, 2001, 40 (24) : 4387 - 4394
  • [10] A comparison of near-infrared diode laser techniques for airborne hygrometry
    Silver, JA
    Hovde, DC
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 1998, 15 (01) : 29 - 35