A novel diagnostic in situ derivatization kit for the simultaneous determination of 14 biomarkers of exposure to benzene, toluene, ethyl benzene and xylenes in human urine by isotope dilution liquid chromatography tandem mass spectrometry and kit optimization using response surface methodology

被引:5
|
作者
Baghdady, Yehia Z. [1 ]
Schug, Kevin A. [1 ]
机构
[1] Univ Texas Arlington, Dept Chem & Biochem, Arlington, TX 76019 USA
关键词
In situ derivatization; Biomarkers; BTEX; Central composite design; Occupational exposure; Metabolites; VOLATILE ORGANIC-COMPOUNDS; PARA-METHYLHIPPURIC ACIDS; HIPPURIC-ACID; GAS-CHROMATOGRAPHY; QUANTITATIVE-DETERMINATION; FATTY-ACIDS; METABOLITES; EXTRACTION; ETHYLBENZENE; VALIDATION;
D O I
10.1016/j.aca.2018.06.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Metabolite profiling can be used as a diagnostic measure for both short and long term co-exposure by individuals to benzene, toluene, ethylbenzene and xylenes (BTEX). A novel one pot derivatization in situ kit (OPDISK) was developed and optimized using a multivariate approach based on central composite design. The OPDISK was designed to simultaneously derivatize, in a urine sample matrix, a series of fourteen carboxylic acid and phenol-bearing urinary metabolites of BTEX to enhance their chromatographic analysis and sensitivity for detection by liquid chromatography - electrospray ionization - tandem mass spectrometry (LC-ESI-MS/MS). Using the reagent kit, the less responsive functional units on the molecules were converted to permanently positively-charged functional units. The kit was composed of three components, 2-fluoro-1-methylpyridinium p-toluenesulfonate (FMP), 3-carbinol-1-methylpyridinium iodide (CMP) and triethylamine (TEA) as a basic catalyst and, only after diluting a urine sample 20 fold with acetonitrile, was applied under mild conditions of room temperature and short reaction time of 20 min. The derivatized biomarkers were then directly analyzed using isotope dilution LC-ESI-MS/MS. The method was sensitive (limit of detection on column ranged from 1.4 pg to 3.1 ng), accurate (mean accuracy from 85% to 114%), and precise (mean coefficient of variation from 1% to 14%). The method results indicated a good linearity (R-2 >= 0.990) for all metabolites. ClinChek (R) urine control samples were used successfully to demonstrate the accuracy of the method. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 4 条
  • [1] Simultaneous determination of benzene, toluene, ethylbenzene, and xylene metabolites in human urine using electromembrane extraction combined with liquid chromatography and tandem mass spectrometry
    Suh, Joon Hyuk
    Lee, Hye Yeon
    Kim, Unyong
    Eom, Han Young
    Kim, Junghyun
    Cho, Hyun-Deok
    Han, Sang Beom
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (24) : 4276 - 4285
  • [2] Simultaneous Determination of 11 β-Agonists in Human Urine Using High-Performance Liquid Chromatography/Tandem Mass Spectrometry with Isotope Dilution
    Wang, Xiaoli
    Guo, Tao
    Wang, Shanshan
    Yuan, Jinpeng
    Zhao, Rusong
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (03) : 213 - 218
  • [3] Simultaneous determination of nine neonicotinoids in human urine using isotope-dilution ultra-performance liquid chromatography tandem mass spectrometry
    Zhang, Quan
    Wang, Ximing
    Li, Zhe
    Jin, Hangbiao
    Lu, Zhengbiao
    Yu, Chang
    Huang, Yu-fang
    Zhao, Meirong
    ENVIRONMENTAL POLLUTION, 2018, 240 : 647 - 652
  • [4] Simultaneous determination of seven β2-agonists in human and bovine urine by isotope dilution liquid chromatography-tandem mass spectrometry using compound-specific minimally 13C-labelled analogues
    Gonzalez-Antuna, Ana
    Rodriguez-Gonzalez, Pablo
    Centineo, Giuseppe
    Ignacio Garcia Alonso, J.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1372 : 63 - 71