Bismuth Microelectrode Array for Adsorptive Stripping Voltammetry to Detect Lead and Cadmium in Beverage

被引:8
|
作者
Liu De-Meng [1 ,2 ]
Jin Yan [1 ,2 ]
Jin Qing-Hui [1 ]
Zhao Jian-Long [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China
关键词
Bismuth array; Lead; Cadmium; Adsorptive stripping voltammetry; HEAVY-METAL ANALYSIS; ELECTRODES; CARBON; IONS; FILM;
D O I
10.3724/SP.J.1096.2011.01748
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A heavy metal sensor fabricated by microelectronic mechanical system (MEMS) technology was described in this study. The sensor is three-electronic system which consisted of Bi microelectronic array working electrode, Pt counter electrode and Ag/AgCl reference electrode. Bi is low-toxic heavy metal, so the using of Bi as reaction substances can make detection process more safely. Microarray electrode takes many advantages, such as high-throughput, miniaturization and anti-interference. The experiment result shows that the sensor has a good performance in simultaneously detecting Pb2+, Cd2+. The detection limits of these two metals are 0.067 mg/L (Pb) and 0.064 mg/L (Cd) respectively with good repeatability. The sensor has been applied to detect Pb2+ (0.1 mg/L) and Cd2+ (0.025 mg/L) in Orange juice with satisfactory results.
引用
收藏
页码:1748 / 1752
页数:5
相关论文
共 13 条
  • [1] Anodic stripping voltammetry at in situ bismuth-plated carbon and gold microdisc electrodes in variable electrolyte content unstirred solutions
    Baldrianova, L.
    Svancara, I.
    Economou, A.
    Sotiropoulos, S.
    [J]. ANALYTICA CHIMICA ACTA, 2006, 580 (01) : 24 - 31
  • [2] Screen-printed anodic stripping voltammetric sensor containing HgO for heavy metal analysis
    Choi, JY
    Seo, K
    Cho, SR
    Oh, JR
    Kahng, SH
    Park, J
    [J]. ANALYTICA CHIMICA ACTA, 2001, 443 (02) : 241 - 247
  • [3] Gong WL, 2008, CHINESE J ANAL CHEM, V36, P177
  • [4] Karel Stulik., 2000, Pure Appl. Chem, V72, P1483
  • [5] Novel disposable bismuth-sputtered electrodes for the determination of trace metals by stripping voltammetry
    Kokkinos, Christos
    Economou, Anastasios
    Raptis, Loannis
    Efstathiou, Constantinos E.
    Speliotis, Thanasis
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (12) : 2795 - 2800
  • [6] Li JP, 2002, CHINESE J ANAL CHEM, V30, P1092
  • [7] Heavy metal analysis of rainwaters: A comparison of TXRF and ASV analytical capabilities
    Montero Alvarez, A.
    Estevez Alvarez, J. R.
    Padilla Alvarez, R.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 273 (02) : 427 - 433
  • [8] Microfabricated electrochemical analysis system for heavy metal detection
    Reay, RJ
    Flannery, AF
    Storment, CW
    Kounaves, SP
    Kovacs, GTA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) : 450 - 455
  • [9] Bismuth-coated diamond-like carbon microelectrodes for heavy metals determination
    Rehacek, Vlastimil
    Hotovy, Ivan
    Vojs, Marian
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (01) : 193 - 197
  • [10] Detection of heavy metal ions in water by high-resolution surface plasmon resonance spectroscopy combined with anodic stripping voltammetry
    Wang, Shaopeng
    Forzani, Erica S.
    Tao, Nongjian
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (12) : 4427 - 4432