Multiphase-computed tomography-based target volume definition in conventional fractionated radiotherapy of lung tumors: dosimetric and reliable comparison with the technique using addition of generic margins

被引:0
|
作者
Wang, Zheng [1 ,2 ]
Lu, Xueguan [1 ]
Zhou, Gang [1 ]
Yan, Liming [1 ]
Zhang, Liyuan [1 ]
Zhu, Yaqun [1 ]
Tian, Ye [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 2, Dept Radiat Oncol, Suzhou 215004, Jiangsu, Peoples R China
[2] Soochow Univ, Changshu Affiliated Hosp, Dept Radiat Oncol, Suzhou 215004, Jiangsu, Peoples R China
关键词
conventional radiotherapy; internal target volume; lung neoplasm; tumor motion; EXTERNAL-BEAM RADIOTHERAPY; DYNAMIC MRI; CANCER; MOTION; CT; MOBILITY;
D O I
10.1177/030089161109700511
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims and background. The aim of the present study was to compare radiotherapeutic plans based on internal target volume determined by between multiphase computed tomography and addition of a generic margin in lung tumors and to evaluate the reliability of ITV determined by multiphase computed tomography during conventional fractionated radiotherapy. Methods and study design. The radiotherapeutic plans based on internal target volume determined by between multiphase computed tomography and addition of a generic margin in 10 patients with lung tumors were applied. The difference of two planning target volumes (PTV) and irradiated dose and volume of normal lung tissue were compared. Weekly new targets were delineated on repeated computed tomography scans, and weekly dose coverage of clinical target volume under two different treatment plans was evaluated. Results. For all patients, PTV(3CT) volume based on multiphase computed tomography was significantly smaller than that of PTV(con) based on addition of a generic margin (t = 6.831, P<0.001). The volume receiving more than 20 Gy in Plan(3CT) and Plan(con) was 16.7 +/- 5.2% and 20.0 +/- 5.2% (t = 7.565, P<0.001), the volume receiving more than 5 Gy was 36.6 +/- 7.2% and 42.7 +/- 6.4% (t = 7.459, P<0.001), and mean lung dose was 1037.5 +/- 275.0 cGy and 1246.8 +/- 271.0 cGy (t = 8.078, P<0.001), respectively. Both Plan(3CT) and Plan(con) provided a satisfactory clinical target volume coverage weekly during conventional fractionated radiotherapy for 6-7 weeks, and the ratio of the volume receiving the prescription dose was 1.03 +/- 0.02 and 1.04 +/- 0.02, respectively. Conclusions. The radiotherapeutic plan based on internal target volume determined by multiphase computed tomography can ensure weekly target coverage during conventional fractionated radiotherapy in lung tumors, and it is better than the plan based on the addition of generic internal target volume, which can effectively reduce normal lung tissue irradiation.
引用
收藏
页码:603 / 608
页数:6
相关论文
共 19 条
  • [1] 4D-CT-based target volume definition in stereotactic radiotherapy of lung tumours: Comparison with a conventional technique using individual margins
    Hof, Holger
    Rhein, Bernhard
    Haering, Peter
    Kopp-Schneider, Annette
    Debus, Juergen
    Herfarth, Klaus
    RADIOTHERAPY AND ONCOLOGY, 2009, 93 (03) : 419 - 423
  • [2] 4DCT-Based Plan Target Volume Definition in IMRT of Lung Cancer: Comparison With a Conventional Technique Using General Margins
    Zhou, Z.
    Ju, X.
    Li, M.
    Wang, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S516 - S516
  • [3] A comparison of internal target volume definition by limited four-dimensional computed tomography, the addition of patient-specific margins, or the addition of generic margins when planning radical radiotherapy for lymph node-positive non-small cell lung cancer
    Hughes, S.
    McClelland, J.
    Chandler, A.
    Adams, M.
    Boutland, J.
    Withers, D.
    Ahmad, S.
    Blackall, J.
    Tarte, S.
    Hawkes, D.
    Landau, D.
    CLINICAL ONCOLOGY, 2008, 20 (04) : 293 - 300
  • [4] Investigation on cone-beam computed tomography-based liver cancer radiotherapy clinical target volume planning target volume margin and analysis of dosimetric differences
    Zhenghuan, Li
    Manya, Wu
    Fantu, Kong
    Jie, Dong
    Yuan, Cheng
    Qinghe, Peng
    Junyue, Shi
    Huamei, Yan
    Xiangying, Xu
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (02)
  • [5] Efficient approach for determining four-dimensional computed tomography-based internal target volume in stereotactic radiotherapy of lung cancer
    Yeo, Seung-Gu
    Kim, Eun Seog
    RADIATION ONCOLOGY JOURNAL, 2013, 31 (04): : 247 - 251
  • [6] Dosimetric comparison of conventional radiograph- and three-dimensional computed tomography-based planning using dose volume indices for partial breast intraoperative implants
    Sharma, S. D.
    Budrukkar, A.
    Upreti, R. R.
    Munshi, A.
    Jatali, R.
    Deshpande, D. D.
    CLINICAL ONCOLOGY, 2008, 20 (01) : 46 - 52
  • [7] Investigation of approaches for internal target volume definition using 4-dimensional computed tomography in stereotactic body radiotherapy of lung cancer
    Koksal, Canan
    Kesen, Nazmiye Donmez
    Okutan, Murat
    Karaman, Sule
    Sakin, Nergiz Dagoglu
    Bilge, Hatice
    MEDICAL DOSIMETRY, 2021, 46 (02) : 136 - 142
  • [8] Comparison of internal target volume delineation using CT datasets of four-dimensional computed tomography in lung cancer radiotherapy
    Bushra, S.
    Tibdewal, A.
    Mummudi, N.
    Kinhikar, R.
    Ghadi, Y.
    Agarwal, J. P.
    ANNALS OF ONCOLOGY, 2019, 30
  • [9] Dual-Energy Computed Tomography-Based Iodine Quantitation for Response Evaluation of Lung Cancers to Chemoradiotherapy/Radiotherapy: A Comparison With Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography-Based Positron Emission Tomography/Computed Tomography Response Evaluation Criterion in Solid Tumors
    Ren, Yanping
    Jiao, Yuxin
    Ge, Weiqiang
    Zhang, Libo
    Hua, Yanqing
    Li, Cheng
    Zhai, Weihao
    Tang, Xi
    He, Wei
    Fang, Min
    Zheng, Xiangpeng
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (04) : 614 - 622
  • [10] The potential failure risk of the cone-beam computed tomography-based planning target volume margin definition for prostate image-guided radiotherapy based on a prospective single-institutional hybrid analysis
    Hirose, Katsumi
    Sato, Mariko
    Hatayama, Yoshiomi
    Kawaguchi, Hideo
    Komai, Fumio
    Sohma, Makoto
    Obara, Hideki
    Suzuki, Masashi
    Tanaka, Mitsuki
    Fujioka, Ichitaro
    Ichise, Koji
    Takai, Yoshihiro
    Aoki, Masahiko
    RADIATION ONCOLOGY, 2018, 13