Design of an active-passive device for human ankle movement during functional magnetic resonance imaging analysis

被引:5
|
作者
Belforte, Guido [1 ]
Eula, Gabriella [1 ]
机构
[1] Politecn Torino Tech Univ, Dept Mech, Turin, Italy
关键词
Mechatronic devices in functional magnetic resonance imaging analysis; magnetic resonance compatible automatic devices; functional magnetic resonance imaging mechatronic system; DORSIFLEXION; INVESTIGATE;
D O I
10.1177/0954411911426946
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Functional magnetic resonance imaging analysis has made major strides in recent years, both because of the development of new scanners and owing to magnetic resonance compatible systems that make it possible to stimulate parts of the human body during analysis. The significant gains in our knowledge of the brain that can thus be achieved justify efforts to construct machines with control circuits suitable for this purpose. This paper presents a magnetic resonance compatible mechatronic device with electropneumatic control that can be used to move one or both feet during functional magnetic resonance imaging analysis of the cerebral motor zones. The system is innovative and original. The results obtained at the end of the investigation were good, and demonstrated that the design is feasible.
引用
收藏
页码:21 / 32
页数:12
相关论文
共 50 条
  • [1] Design and Analysis of the Active-Passive Hybrid Ankle Prosthesis Based on Electro-Hydraulic Actuation
    Pang, Hao
    Shan, Shaopeng
    Han, Yang
    Li, Zhennan
    Zhang, Sen
    Liu, Chunbao
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2024, 52 (09): : 72 - 80
  • [2] A study of the motor and sensory cortex using functional magnetic resonance:: Tasks of active and passive movement
    Alvarez-Linera, J
    Martín, P
    Maestú, F
    Pulido, P
    Iglesias, J
    Serrano, JM
    Sola, RG
    REVISTA DE NEUROLOGIA, 1999, 28 (07) : 681 - 685
  • [3] Negative BOLD during tongue movement: A functional magnetic resonance imaging study
    Sakamoto, Kiwako
    Nakata, Hiroki
    Perrucci, Mauro Gianni
    Del Gratt, Cosimo
    Kakigi, Ryusuke
    Romani, Gian Luca
    NEUROSCIENCE LETTERS, 2009, 466 (03) : 120 - 123
  • [4] A delivery device for presentation of tactile stimuli during functional magnetic resonance imaging
    Dykes, Robert W.
    Miquee, Aline
    Xerri, Christian
    Zennou-Azogui, Yoh'i
    Rainville, Constant
    Dumoulin, Andre
    Marineau, Daniel
    JOURNAL OF NEUROSCIENCE METHODS, 2007, 159 (02) : 308 - 317
  • [5] On Experimenting with Functional Magnetic Resonance Imaging of Lip Movement
    Satheeshkumar, J.
    Rajesh, R.
    Arumugaperumal, S.
    Kesavdas, C.
    NEURORADIOLOGY JOURNAL, 2008, 21 (01): : 23 - 30
  • [6] Functional magnetic resonance imaging of the human brain: data acquisition and analysis
    R. Turner
    Alastair Howseman
    Geraint E. Rees
    Oliver Josephs
    Karl Friston
    Experimental Brain Research, 1998, 123 : 5 - 12
  • [7] Functional magnetic resonance imaging of human olfaction
    Wiesmann, M
    Yousry, I
    Heuberger, E
    Nolte, A
    Ilmberger, J
    Kobal, G
    Yousry, TA
    Kettenmann, B
    Naidich, TP
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2001, 11 (02) : 237 - +
  • [8] Functional magnetic resonance imaging of the human brain: data acquisition and analysis
    Turner, R
    Howseman, A
    Rees, GE
    Josephs, O
    Friston, K
    EXPERIMENTAL BRAIN RESEARCH, 1998, 123 (1-2) : 5 - 12
  • [9] Functional magnetic resonance imaging of the human brain
    Kim, SG
    Ugurbil, K
    JOURNAL OF NEUROSCIENCE METHODS, 1997, 74 (02) : 229 - 243
  • [10] Functional imaging of the human placenta with magnetic resonance
    Siauve, Nathalie
    Chalouhi, Gihad E.
    Deloison, Benjamin
    Alison, Marianne
    Clement, Olivier
    Ville, Yves
    Salomon, Laurent J.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2015, 213 (04) : S103 - S114