Stimulation of the expiratory muscles using micro stimulators

被引:6
|
作者
Lin, Vernon W. -H. [1 ,2 ]
Deng, Xiaoming [1 ]
Lee, Yu-Shang [1 ]
Hsiao, Ian N. [1 ]
机构
[1] Univ Calif Irvine, Sch Med, Dept Phys Med & Rehabil, Orange, CA 92868 USA
[2] VA Long Beach Healthcare Syst, Long Beach, CA 90822 USA
关键词
cough; expiratory muscles; microstimulator; spinal cord injury;
D O I
10.1109/TNSRE.2008.926705
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory complications constitute a major cause of morbidity and mortality in patients with spinal cord injury. These complications arise in part due to the loss of supraspinal control over the expiratory muscles and the resultant difficulties in clearing airway secretions effectively. The purpose of the present study is to evaluate the efficacy of lower thoracic spinal nerve stimulation using wireless microstimulators in activating the expiratory muscles. Studies were performed on nine anesthetized dogs. A thoracic laminectomy was performed on each dog, and was followed by spinal cord transection at T2. A total of 16 microstimulators (supplied by the Alfred Mann Foundation, Santa Clarita, CA) were inserted percutaneously into the bilateral intercostal nerves approximately 1 similar to 3 cm distal to the neuroforamen from T7 to L1 in each dog. The stimulation parameters were: frequency of 20 Hz, pulse width of 200 mu s, and stimulation burst of 2 s. The stimulation intensities were 3.78, 5.4, 8.1, and 10.8 mA. The pressure-generating capacity of the expiratory muscles was evaluated by the change in airway pressure (P-aw) at functional residual capacity, which was produced by the microstimulators during airway occlusion. As a general trend, the expiratory pressure generated using the microstimulators increased with increasing intensity and the number of spinal nerves recruited. The maximal expiratory pressures generated from one, two, three, four, five, six, seven, and eight pairs of spinal nerves were 8.4 +/- 0.8, 12.2 +/- 1.0, 14.6 +/- 1.4, 17.8 +/- 1.8, 23.0 +/- 1.8, 27.7 +/- 2.2, 35.2 +/- 2.7, and 40.4 +/- 2.9 cmH(2)O, respectively. Bilateral stimulation of seven (from T8 to L1) and eight spinal nerve levels (from T7 to L1) produced the highest changes in (P-aw). Stimulation of six or less spinal nerve levels resulted in significantly lower (P-aw) - we conclude: 1) lower thoracic spinal nerve stimulation near the neuroforamen using microstimulators produces significant expiratory pressure, 2) percutaneous placement of the microstimulators near the neuroforamen is effective in producing expiratory pressure, and 3) percutaneous placement of the microstimulators for restoring cough may potentially be used as a relatively noninvasive clinical tool for patients with spinal cord injury, or other neurological or respiratory disorders. Further studies will be needed.
引用
收藏
页码:416 / 420
页数:5
相关论文
共 50 条
  • [1] Electrode Positioning During Electrical Stimulation of the Expiratory Muscles
    Hidalgo, D. Colon
    Laghi, F. A.
    McLachlan, A.
    Djondo, D.
    Pellegrino, G. M.
    Papa, G. Sferrazza
    Tobin, M. J.
    Shaikh, H. S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [2] Effects of chronic electrical stimulation on paralyzed expiratory muscles
    DiMarco, Anthony F.
    Kowalski, Krzysztof E.
    JOURNAL OF APPLIED PHYSIOLOGY, 2008, 104 (06) : 1634 - 1640
  • [3] Intraspinal Stimulation with Light Activated Micro-Stimulators
    Abdo, Ammar
    Sahin, Mesut
    Freedman, David S.
    Cevik, Elif
    Spuhler, Philipp S.
    Unlu, M. Selim
    2011 5TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2011, : 546 - 549
  • [4] Functional Magnetic Stimulation of Inspiratory and Expiratory Muscles in Subjects With Tetraplegia
    Zhang, Xiaoming
    Plow, Ela
    Ranganthan, Vinoth
    Huang, Honglian
    Schmitt, Melissa
    Nemunaitis, Gregory
    Kelly, Clay
    Frost, Frederick
    Lin, Vernon
    PM&R, 2016, 8 (07) : 651 - 659
  • [5] Improved coil design for functional magnetic stimulation of expiratory muscles
    Hsiao, IN
    Lin, VWH
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (06) : 684 - 694
  • [6] Expiratory flow limitation detected using neuromuscular electrical stimulation of abdominal-wall muscles
    Laghi, F. A.
    Schnell, T.
    McLachlan, A.
    Casserly, B.
    Tobin, M. J.
    Shaikh, H.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2017, 186 : S423 - S423
  • [7] Expiratory flow limitation detected using neuromuscular electrical stimulation of abdominal-wall muscles
    Laghi, F. A.
    Schnell, T.
    McLachlan, A.
    Casserly, B.
    Tobin, M. J.
    Shaikh, H.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2017, 186 (SUPPL 10) : S423 - S423
  • [8] Coactivation of Expiratory Muscles and Diaphragm During, Electrical Stimulation to the Abdominal Wall
    Hidalgo, D. Colon
    Mclachlan, A. J.
    Shaikh, H. S.
    Ansar, A.
    Tobin, M. J.
    Laghi, F.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [9] Functional magnetic stimulation of the expiratory muscles in patients with spinal cord injury
    Lin, VWH
    Singh, H
    Sasaki, R
    Perkash, I
    EXPERIMENTAL NEUROLOGY, 1998, 151 (01) : 155 - 156
  • [10] Functional magnetic stimulation for conditioning of expiratory muscles in patients with spinal cord injury
    Lin, VW
    Hsiao, IN
    Zhu, EC
    Perkash, I
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (02): : 162 - 166