Pulse-rate discrimination deficit in cochlear implant users: is the upper limit of pitch peripheral or central?

被引:15
|
作者
Zhou, Ning [1 ]
Mathews, Juliana [1 ]
Dong, Lixue [1 ]
机构
[1] East Carolina Univ, Dept Commun Sci & Disorders, Greenville, NC 27834 USA
关键词
Spread of excitation; Multipulse integration; Speech recognition; Temporal processing; FREQUENCY DIFFERENCE LIMENS; TEMPORAL PITCH; ELECTRICAL-STIMULATION; AUDITORY-NERVE; SPEECH-PERCEPTION; RECOGNITION; LIMITATIONS; DURATION; NOISE;
D O I
10.1016/j.heares.2018.10.018
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Cochlear implant (CI) users do not reliably associate an increase in pulse rate above 300 pulses per second (pps) with an increase in pitch. The locus of this upper limit of pitch remains unknown. The present study tested the hypothesis that this deficit resides at least initially at the auditory nerve. The hypothesis was tested by comparing pulse rate discrimination in different neural excitation patterns, in which a large versus small population of auditory nerve fibers was activated. If poorer pulse rate discrimination was found under conditions where narrower spread of neural excitation (SOE) was anticipated where a relatively small neural population was activated, then it would support the hypothesis that the rate processing deficit found in CI users is related to peripheral neural degeneration. Nine listeners (12 ears) implanted with the Cochlear Americas Nucleus (R) devices participated in the study. Different SOE conditions were created by (1) selecting electrodes that showed narrow versus broad forward-masked psychophysical spatial tuning curves, and (2) by measuring these electrodes in monopolar (MP) and narrow bipolar (BPO) electrode configurations. Rate discrimination difference limen (DL) was measured at the selected electrodes in two electrode configurations at three base rates (200, 300 and 500 pps). Consistent with the prediction, group mean DL was better (1) at stimulation sites measured with broader tuning, and (2) in MP relative to BP stimulation. These effects were more salient at the more challenging base rates. There was a weak relationship between rate discrimination (above thresholds) and the effect of rate on detection thresholds. Finally, rate discrimination at rates above the known upper limit (i.e., 500 pps) was correlated with duration of deafness and highly predicted the subjects' speech recognition performance in noise. These findings support that pulse rate discrimination depends, at least partially, on neural conditions at the auditory periphery and this peripheral limit predicts speech recognition outcomes with a CI. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [1] Effect of Pulse Rate on Loudness Discrimination in Cochlear Implant Users
    Azadpour, Mahan
    McKay, Colette M.
    Svirsky, Mario A.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2018, 19 (03): : 287 - 299
  • [2] Effect of Pulse Rate on Loudness Discrimination in Cochlear Implant Users
    Mahan Azadpour
    Colette M. McKay
    Mario A. Svirsky
    Journal of the Association for Research in Otolaryngology, 2018, 19 : 287 - 299
  • [3] Musical Pitch Discrimination by Cochlear Implant Users
    Ping, Lichuan
    Yuan, Meng
    Feng, Haihong
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2012, 121 (05): : 328 - 336
  • [4] Rate discrimination, gap detection and ranking of temporal pitch in cochlear implant users
    Cosentino, Stefano
    Carlyon, Robert P.
    Deeks, John M.
    Parkinson, Wendy
    Bierer, Julie A.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2016, 17 (04): : 371 - 382
  • [5] Rate discrimination, gap detection and ranking of temporal pitch in cochlear implant users
    Stefano Cosentino
    Robert P. Carlyon
    John M. Deeks
    Wendy Parkinson
    Julie A. Bierer
    Journal of the Association for Research in Otolaryngology, 2016, 17 : 371 - 382
  • [6] Pitch discrimination and melody recognition by cochlear implant users
    Looi, V
    McDermott, H
    McKay, C
    Hickson, L
    COCHLEAR IMPLANTS, 2004, 1273 : 197 - 200
  • [7] Pitch discrimination of cochlear implant users depending on the stimulations place and the stimulations rate.
    Simonyan, A.
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2012, 129 (02): : 102 - 106
  • [8] Pulse-rate discrimination by cochlear-implant and normal-hearing listeners with and without binaural cues
    Carlyon, Robert P.
    Long, Christopher J.
    Deeks, John M.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 123 (04): : 2276 - 2286
  • [9] Pulse-rate discrimination by cochlear-implant and normal-hearing listeners with and without binaural cues
    Carlyon, Robert P.
    Long, Christopher J.
    Deeks, John M.
    Journal of the Acoustical Society of America, 2008, 123 (04): : 2276 - 2286
  • [10] Effects of pulse shape on pitch sensitivity of cochlear implant users
    Arslan, Niyazi O.
    Luo, Xin
    HEARING RESEARCH, 2024, 450