A state of the art Lambertson septum magnet of the RHIC beam injection system ?

被引:4
|
作者
Tsoupas, N. [1 ]
机构
[1] Brookhaven Natl Lab, Collider Accelerator Dept, Upton, NY 11973 USA
关键词
Beam injection system; Lambertson septum magnet;
D O I
10.1016/j.nima.2020.164167
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The beam injection system of the Relativistic Heavy Ion Collider (RHIC) is the last section of the beam transfer line which transports the beam from the Alternating Gradient Synchrotron (AGS) to RHIC and comes under the acronym AtR (AGS to RHIC) (https://ieeexplore.ieee.org/document/749599, https://ieeexplore.ieee.org/abstract/document/749594). The Lambertson septum magnet is one of the magnetic elements of the RHIC injection system (https://ieeexplore.ieee.org/abstract/document/749594). This paper presents results from the 2D and 3D electromagnetic design of the RHIC Lambertson septum magnet which has unique design features to minimize the magnetic field at the circulated beam region including the fringe field regions at the entrance and exit of the magnet. © 2020 Elsevier B.V.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] The Extraction Lambertson Septum Magnet of the SNS
    Rank, J
    Miglionico, G
    Raparia, D
    Tsoupas, N
    Tuozzolo, J
    Lee, YY
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 1186 - 1188
  • [2] Design end B-field measurements of a Lambertson injection magnet for the rhic machine
    Tsoupas, N
    Rodger, E
    Claus, J
    Foelsche, HW
    Wanderer, P
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 1352 - 1354
  • [3] Impact of the Lambertson septum magnet on the photon beam flux in the PLS-II beam line experiment
    D-E. Kim
    K-H. Park
    H-S. Seo
    I. Hwang
    S. Shin
    K-R. Kim
    J-Y. Huang
    S. Nam
    Journal of the Korean Physical Society, 2014, 64 : 197 - 204
  • [4] Impact of the Lambertson septum magnet on the photon beam flux in the PLS-II beam line experiment
    Kim, D-E.
    Park, K-H.
    Seo, H-S.
    Hwang, I.
    Shin, S.
    Kim, K-R.
    Huang, J-Y.
    Nam, S.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (02) : 197 - 204
  • [5] Design considerations for a Lambertson Septum magnet for the spallation neutron source
    Rank, J
    Malm, K
    Miglionico, G
    Raparia, D
    Tsoupas, N
    Tuozzolo, J
    Lee, YY
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 2150 - 2152
  • [6] A state of the art current-septum dipole magnet
    Tsoupas, N.
    Brown, K.
    Meot, F.
    Pearson, C.
    Pile, P.
    Ptitsyn, V.
    Rusek, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 923 : 8 - 18
  • [7] Beam injection into RHIC
    Fischer, W
    Hahn, H
    MacKay, WW
    Satogata, T
    Tsoupas, N
    Zhang, W
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 210 - 212
  • [8] Lambertson Magnet with Shortened Loop for Nuclotron Injection and Extraction Systems
    Alfeev, A. V.
    Butenko, A. V.
    Volkov, V. I.
    Vorozhtsov, S. B.
    Goncharov, I. N.
    Donets, D. E.
    Kozlov, O. S.
    Mikhailov, V. A.
    Monchinsky, V. A.
    Novikov, S. A.
    Sidorin, A. O.
    Smirnov, A. V.
    Smirnov, V. L.
    Romanov, S. V.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2016, 13 (07) : 927 - 933
  • [10] NEW CURRENT SEPTUM MAGNET USED FOR BEAM INJECTION AND EXTRACTION IN UHV
    KAWAKUBO, T
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (02): : 188 - 188