A comparison of the disposable versus the reusable laryngeal mask airway in paralyzed adult patients

被引:64
|
作者
Brimacombe, J
Keller, C
Morris, R
Mecklem, D
机构
[1] Cairns Base Hosp, Dept Anaesthesia & Intens Care, Cairns, Australia
[2] Leopold Franzens Univ, Dept Anaesthesia & Intens Care Med, Innsbruck, Austria
来源
ANESTHESIA AND ANALGESIA | 1998年 / 87卷 / 04期
关键词
D O I
10.1097/00000539-199810000-00033
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A disposable (polyvinyl chloride) laryngeal mask airway (LMA) with dimensions identical to, but physical properties different from (stiffer tube/thicker cuff), the reusable (silicone) LMA has recently become available. We performed a randomized, cross-over study of 60 paralyzed, anesthetized patients to test the hypothesis that the use of these devices was different in terms of ease of insertion, airway sealing pressure, fiberoptic position, and changes in intracuff pressure during N2O anesthesia. We also tested the hypothesis that the airway sealing pressure of the LMA is suboptimal if the cuff is inflated to a high intracuff pressure. Both the devices were inserted into each patient in random order, and their performance was assessed at two intracuff pressures (60 and 180 cm H2O) by a blind observer. Subsequently, intracuff pressures were measured during N2O anesthesia for the second device. Ease of insertion was similar: there was no difference in first attempt success rates (97% vs 98%) and insertion times (15 vs 13 s) for the disposable and reusable LMA, respectively. There were no differences in airway sealing pressure or fiberoptic position. Airway sealing pressure was significantly higher at 60 cm H2O intracuff pressure compared with the airway sealing pressure at 180 cm H2O for both devices (P < 0.02). During N2O anesthesia, the intracuff pressure remained stable for the disposable LMA but increased significantly for the reusable LMA. We conclude that the disposable and reusable LMAs perform similarly in paralyzed adult patients, but that the disposable LMA has more stable intracuff pressures during N2O anesthesia, inflation of the LMA to high intracuff pressures produces a subpotimal seal. Implications: This randomized, single-blind, within-patient study of 60 adult patients shows that the disposable (polyvinyl chloride) and reusable (silicone) laryngeal mask airways perform similarly, but that the disposable laryngeal mask airway has more stable intracuff pressures during N2O anesthesia. Inflation of either device to high intracuff pressures produces a suboptimal seal.
引用
收藏
页码:921 / 924
页数:4
相关论文
共 50 条
  • [1] Comparison of disposable and reusable laryngeal mask airways in spontaneously ventilating adult patients
    Cao, MM
    Webb, T
    Bjorksten, AR
    ANAESTHESIA AND INTENSIVE CARE, 2004, 32 (04) : 530 - 534
  • [2] Comparison of disposable and reusable laryngeal mask airways in spontaneously ventilating adult patients
    Al-Shaikh, B
    Mathew, G
    Van Zundert, AAJ
    ANAESTHESIA AND INTENSIVE CARE, 2005, 33 (03) : 411 - 411
  • [3] A comparison of the disposable Ambu® AuraOnce™ Laryngeal Mask with the reusable LMA Classic™ laryngeal mask airway
    Sudhir, G.
    Redfern, D.
    Hall, J. E.
    Wilkes, A. R.
    Cann, C.
    ANAESTHESIA, 2007, 62 (07) : 719 - 722
  • [4] A comparison of the Supreme™ laryngeal mask airway with the Proseal™ laryngeal mask airway in anesthetized paralyzed adult patients: a randomized crossover study
    Tham, Huae Min
    Tan, Su Meng
    Woon, Kwee Lian
    Zhao, Yu Dong
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2010, 57 (07): : 672 - 678
  • [5] Pulmonary airway resistance with the endotracheal tube versus laryngeal mask airway in paralyzed anesthetized adult patients
    Berry, A
    Brimacombe, J
    Keller, C
    Verghese, C
    ANESTHESIOLOGY, 1999, 90 (02) : 395 - 397
  • [6] A comparison of the laryngeal mask airway ProSealTM and the laryngeal tube airway in paralyzed anesthetized adult patients undergoing pressure-controlled ventilation
    Brimacombe, J
    Keller, C
    Brimacombe, L
    ANESTHESIA AND ANALGESIA, 2002, 95 (03): : 770 - 776
  • [7] Comparison of the Applicability and Safety of the Cobra Peri laryngeal Airway and the Laryngeal Mask Airway Classic in Anesthetized and Paralyzed Patients
    Ali, Achmet
    Turkmen, Aygen
    Alkan, Irem
    Turgut, Namigar
    Moralar, Dondu
    Altan, Aysel
    KUWAIT MEDICAL JOURNAL, 2014, 46 (02): : 119 - 123
  • [8] The laryngeal mask airway Unique™ versus the Soft Seal™ laryngeal mask:: A randomized, crossover study in paralyzed, anesthetized patients
    Brimacombe, J
    von Goedecke, A
    Keller, C
    Brimacombe, L
    Brimacombe, M
    ANESTHESIA AND ANALGESIA, 2004, 99 (05): : 1560 - 1563
  • [9] A comparison of the disposable vs the reusable laryngeal tube in paralysed adult patients
    Amini, A.
    Zand, F.
    Sadeghi, S. E.
    ANAESTHESIA, 2007, 62 (11) : 1167 - 1170
  • [10] THE TRIPLE AIRWAY MANEUVER FOR INSERTION OF THE LARYNGEAL MASK AIRWAY IN PARALYZED PATIENTS
    AOYAMA, K
    TAKENAKA, I
    SATA, T
    SHIGEMATSU, A
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (11): : 1010 - 1016