Test of Strength: Figure-of-Eight versus Spiral Wrapping Technique for Fiberglass Casts

被引:1
|
作者
Montgomery, Blake K. [1 ]
Storaci, Hunter [1 ]
Segovia, Nicole A. [1 ]
Young, Jeffrey [2 ]
机构
[1] Stanford Univ, Orthopaed Surg, Palo Alto, CA 94304 USA
[2] Stanford Univ, Lucile Packard Childrens Hosp, Orthopaed Surg, Palo Alto, CA 94304 USA
关键词
strength; cast; fiberglass; spiral; figure-of-eight; PLASTER; FRACTURES; PARIS;
D O I
10.7759/cureus.7843
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pediatric fractures are a common injury, and treatment often includes cast immobilization. For pediatric patients being treated in a cast, cast damage is among the most common reasons patients return to the emergency room. The figure-of-eight wrapping technique interdigitates layers of fiberglass which may create a stronger cast. The aim of this study was to assess the strength of the figure-of-eight wrapping technique in comparison to the spiral wrapping technique. A total of 10 casts were wrapped with a three-inch fiberglass using the spiral technique and 10 casts were wrapped using the figure-of-eight technique. Each cast was then subjected to a three-point bending test and loaded until failure using an Instron machine. The figure-of-eight technique had an average load to failure of 278.2 + 27.6 N/mm which was similar to the spiral technique's load to failure of 281.2 + 25.4 N/mm (p=0.795). Prior to normalizing for thickness, the load to failure of the figure-of-eight technique was 949.8 + 109.5 N, which was significantly higher than the spiral technique of 868.2 + 65.1 N (p=0.038). The figure-of-eight casts were slightly thicker than the spiral casts (average 0.3 mm, p=0.004). This suggests that the thickness of the fiberglass cast may improve the strength. The figure-of-eight wrapping technique had similar biomechanical characteristics to spiral wrapping techniques. Providers should wrap in whichever technique they feel most comfortable performing as there is no difference in strength of the cast. If a stronger cast is desired, then thickness of the cast can be increased.
引用
收藏
页数:7
相关论文
共 48 条
  • [1] Clarification of the Figure-of-Eight Suture Technique
    M. Yazar
    B. Yigit
    E. Guven
    U. Emekli
    Aesthetic Plastic Surgery, 2008, 32 : 399 - 400
  • [2] Clarification of the figure-of-eight suture technique
    Yazar, M.
    Yigit, B.
    Guven, E.
    Emekli, U.
    AESTHETIC PLASTIC SURGERY, 2008, 32 (02) : 399 - 400
  • [3] A useful technique for securing nails: the figure-of-eight suture
    Arrowsmith, J
    Bindra, R
    BRITISH JOURNAL OF PLASTIC SURGERY, 2002, 55 (03): : 266 - 266
  • [4] Figure-of-Eight Suspension Suture in Open Technique Septorhinoplasty
    Celik, Mehmet
    Cayonu, Melih
    Comoglu, Senol
    Kanliada, Deniz
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (08) : 2080 - 2082
  • [5] A useful technique for securing nails: the figure-of-eight suture
    Jeys, LM
    Khafagy, R
    BRITISH JOURNAL OF PLASTIC SURGERY, 2001, 54 (07): : 651 - 651
  • [6] Figure-of-eight wiring technique may hamper sternal growth
    Erdinc, M
    Ocal, A
    Ozturk, C
    Sezer, H
    ANNALS OF THORACIC SURGERY, 1999, 67 (04): : 1209 - 1210
  • [7] A Simple Modification of the Conventional Figure-of-Eight Sternal Closure Technique
    Toshiyuki Karigyo, Carlos Junior
    Pesarini, Aldo
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2019, 34 (04) : 406 - 411
  • [8] The figure-of-eight suture technique used for complicated wound closure
    Cigna, Emanuele
    Palumbo, Francesca
    Scuderi, Nicolo
    AESTHETIC PLASTIC SURGERY, 2008, 32 (01) : 177 - 177
  • [9] The Figure-of-Eight Suture Technique Used for Complicated Wound Closure
    Emanuele Cigna
    Francesca Palumbo
    Nicoló Scuderi
    Aesthetic Plastic Surgery, 2008, 32 : 177 - 177
  • [10] Figure-of-eight versus a sling for the treatment of fractured clavicles in children
    Badawy, MK
    Conners, GP
    PEDIATRIC RESEARCH, 2004, 55 (04) : 112A - 112A