The new international reference system for pure α- and pure β-emitting radionuclides and some electron capture decaying radionuclides by liquid scintillation counting

被引:11
|
作者
Coulon, Romain [1 ]
Broda, Ryszard [2 ]
Cassette, Philippe [3 ]
Courte, Sammy [1 ]
Dupire, Aldo [1 ]
Jerome, Simon [4 ]
Judge, Steven [1 ]
Kossert, Karsten [5 ]
Liu, Haoran [6 ]
Michotte, Carine [1 ]
Nonis, Manuel [1 ]
机构
[1] Bur Int Poids & Mesures, Pavillon Breteuil, F-92312 Sevres, France
[2] Natl Ctr Nucl Res Radioisotope Ctr POLATOM, PL-05400 Otwock, Poland
[3] Univ Paris Saclay, CEA, Lab Natl Henri Becquerel, LNE,LNHB,LIST, F-91120 Palaiseau, France
[4] Norges Miljo Biovitenskapelige Univ NMBU, N-1433 As, Norway
[5] Phys Tech Bundesanstalt PTB, Bundesallee 100, D-38116 Braunschweig, Germany
[6] Natl Inst Metrol NIM, Beijing 100029, Peoples R China
关键词
Radionuclide metrology; Key comparisons; Liquid scintillation counting; TDCR; ESIR; TDCR; STANDARDIZATION; STABILITY;
D O I
10.1007/s10967-022-08337-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Bureau International des Poids et Mesures (BIPM) is developing, with the support of national metrology institutes, an extension to the existing international reference system for international comparisons in radionuclide metrology. The extended system is addressing pure alpha-, pure beta-emitting and some electron capture-decaying radionuclides. The new system is based on a custom-built liquid scintillation counter and the triple-to-double coincidence ratio (TDCR) technique. Particular emphasis was placed on long-term stability and excellent reproducibility in sample preparation. The analytical method is based on a special approach that uses the TDCR value as a parameter to compensate for fluctuations caused by changes in detection efficiency or photomultiplier asymmetries that cannot be excluded when considering very long periods. Measures for quality assurance were established. They are based on periodic controls of unquenched toluene-based liquid scintillation sources with H-3 and C-14. In this way, the reproducibility of the system results is demonstrated for a test period of about twenty months.
引用
收藏
页码:3221 / 3230
页数:10
相关论文
共 17 条
  • [1] The new international reference system for pure α- and pure β-emitting radionuclides and some electron capture decaying radionuclides by liquid scintillation counting
    Romain Coulon
    Ryszard Broda
    Philippe Cassette
    Sammy Courte
    Aldo Dupire
    Simon Jerome
    Steven Judge
    Karsten Kossert
    Haoran Liu
    Carine Michotte
    Manuel Nonis
    Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 3221 - 3230
  • [3] Standardization of pure-beta emitting and electron-capture radionuclides by liquid scintillation counting
    Szorenyi, A
    Zsinka, A
    Vagvolgyi, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (2-3): : 359 - 362
  • [4] Standardization of electron-capture radionuclides by liquid scintillation counting
    Malonda, AG
    Carles, AG
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 657 - 662
  • [5] The international reference system for pure β-particle emitting radionuclides: an investigation of the reproducibility of the results
    Coulon, Romain
    Broda, Ryszard
    Cassette, Philippe
    Courte, Sammy
    Jerome, Simon
    Judge, Steven
    Kossert, Karsten
    Liu, Haoran
    Michotte, Carine
    Nonis, Manuel
    METROLOGIA, 2020, 57 (03)
  • [6] The international reference system for pure beta-particle emitting radionuclides: an evaluation of the measurement uncertainties
    Coulon, Romain
    Judge, Steven
    Liu, Haoran
    Michotte, Carine
    METROLOGIA, 2021, 58 (02)
  • [7] A simple counting technique for measuring mixtures of two pure β-emitting radionuclides
    Van Wyngaardt, W. M.
    Simpson, B. R. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 564 (01): : 339 - 346
  • [8] Further investigations of a simple counting technique for measuring mixtures of two pure β-emitting radionuclides
    van Wyngaardt, W. M.
    Simpson, B. R. S.
    Jackson, G. E.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 1012 - 1020
  • [9] PRACTICAL METHOD FOR RESOLUTION OF 2 BETA-EMITTING RADIONUCLIDES BY LIQUID SCINTILLATION COUNTING
    SNIPES, MB
    LENGEMANN, FW
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1971, 22 (09): : 513 - +
  • [10] LIQUID SCINTILLATION-COUNTING OF RADIONUCLIDES EMITTING HIGH-ENERGY BETA-RADIATION
    WIEBE, LI
    MCQUARRIE, SA
    EDISS, C
    MAIERBORST, W
    HELUS, F
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1980, 60 (02): : 385 - 394