Appropriate reliability is a necessary condition for the use of surface EMG for evaluation of hamstring muscle function in cases of knee joint pathologies or ligament injuries. The aim of the study was to investigate the test-retest reliability of power spectrum and amplitude of surface electromyographic (EMG) measurements of semitendinosus (ST) and biceps femoris (BF) during ramp isometric contractions. Eleven males performed maximum isometric contractions (MVC) of the knee flexors in two sessions, a week apart with simultaneous recording of surface EMG of the BF and ST. Intra class correlation (ICC) and standard error measurements (SEM) were applied to assess test-retest reliability of the averaged EMG (aEMG) and the median frequency (MF) over 10 levels of force, from 0% to 100% of the maximum. The ICC values ranged from 0.38 to 0.96 for the aEMG with SEM values reaching 11.37% of MVC. For the MF, the ICCs ranged from 0.44 to 0.98 (SEM range 4.49-18.19 Hz). In our set up, ramp contractions can be used to examine hamstring EMG patterns with acceptable reliability. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:351 / 358
页数:8
相关论文
共 50 条
  • [1] EMG POWER SPECTRA OF ELBOW EXTENSORS DURING RAMP AND STEP ISOMETRIC CONTRACTIONS
    BILODEAU, M
    ARSENAULT, AB
    GRAVEL, D
    BOURBONNAIS, D
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1991, 63 (01): : 24 - 28
  • [2] Normality and stationarity of EMG signals of elbow flexor muscles during ramp and step isometric contractions
    Bilodeau, M
    Cincera, M
    Arsenault, AB
    Gravel, D
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1997, 7 (02) : 87 - 96
  • [3] EMG power spectrum and integrated EMG of ankle planterflexors during stepwise and ramp contractions
    Akasaka, K
    Onishi, H
    Momose, K
    Ihashi, K
    Yagi, R
    Handa, Y
    Hoshimiya, N
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1997, 182 (03): : 207 - 216
  • [4] Biceps femoris and semitendinosus tendon/aponeurosis strain during passive and active (isometric) conditions
    Kellis, Eleftherios
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2016, 26 : 111 - 119
  • [5] EMG amplitude of the biceps femoris during jumping compared to landing movements
    Padulo, Johnny
    Tiloca, Alessandra
    Powell, Douglas
    Granatelli, Giampietro
    Bianco, Antonino
    Paoli, Antonio
    SPRINGERPLUS, 2013, 2 : 1 - 7
  • [6] Reliability of spike and turn variables of surface EMG during isometric voluntary contractions of the biceps brachii muscle
    Lee, Jin
    Jung, Min-Ye
    Kim, Sung-Hwan
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2011, 21 (01) : 119 - 127
  • [7] POWER SPECTRUM OF ELECTROMYOGRAPHY IN ARM AND LEG MUSCLES DURING ISOMETRIC CONTRACTIONS AND FATIGUE
    TARKKA, IM
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 1984, 24 (03): : 189 - 194
  • [8] Mechanomyogram and force relationship during voluntary isometric ramp contractions of the biceps brachii muscle
    Akataki, K
    Mita, K
    Watakabe, M
    Itoh, K
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2001, 84 (1-2) : 19 - 25
  • [9] Mechanomyogram and force relationship during voluntary isometric ramp contractions of the biceps brachii muscle
    Kumi Akataki
    Katsumi Mita
    Makoto Watakabe
    Kunihiko Itoh
    European Journal of Applied Physiology, 2001, 84 : 19 - 25
  • [10] Repeatability of surface EMG variables during voluntary isometric contractions of the biceps brachii muscle
    Rainoldi, A
    Galardi, G
    Maderna, L
    Comi, G
    Lo Conte, L
    Merletti, R
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1999, 9 (02) : 105 - 119