Kinetic performance of reversed-phase C18 high-performance liquid chromatography columns compared by means of the Kinetic Plot Method in pharmaceutically relevant applications

被引:10
|
作者
Fanigliulo, A. [2 ]
Cabooter, D. [1 ]
Bellazzi, G. [2 ]
Allieri, B. [2 ]
Rottigni, A. [2 ]
Desmet, G. [1 ,2 ]
机构
[1] Free Univ Brussels, Dept Chem Engn, B-1050 Brussels, Belgium
[2] GlaxoSmitliKline R&D, Pharmaceut Dev, I-37135 Verona, Italy
关键词
Kinetic Plot Method; Pharmaceutical analysis; Column efficiency; Hybrid silica; Ultra-pure silica; DIFFUSION-COEFFICIENTS; IONIZABLE COMPOUNDS; BASIC COMPOUNDS; PARTICLE-SIZE; LC SUPPORTS; TEMPERATURE; HPLC; PH; REPRESENTATION; RETENTION;
D O I
10.1016/j.chroma.2010.08.071
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Four fully porous C18 columns (Hypersil Gold, ACE3, Xbridge and Gemini NX), widely employed in the pharmaceutical industry, were compared in terms of efficiency and analysis speed with the Kinetic Plot Method. Weakly basic, medium-sized, N-containing pharmaceutical compounds from GlaxoSmithKline Research and Development were used as test molecules. Isocratic elution was carried out at pH 4.5 and pH 8.0 with acetonitrile as organic modifier. The columns under evaluation included highly pure silica supports (Hypersil Gold, ACE3) and hybrid polymer-silica supports (XBridge, Gemini NX). Both types of columns claim for nearly absent secondary interactions with ionized silanol groups and are therefore applicable in a wide pH range. This is an important feature for method development purposes in pharmaceutical industries. The Kinetic Plot Method was used to compare the support characteristics and assess the kinetic performance of the columns in different experimental conditions. Although the evaluated columns have roughly identical particle diameters (from 3.0 to 3.5 mu m) according to their manufacturers, large differences in kinetic performance were observed at pH 4.5 that can be accounted for by different flow resistances, porosities and average particle diameters, experimentally determined from scanning electron microscopy and laser light scattering experiments on loose stationary phase material. The ACE3 column was the best performing support among the evaluated columns, due to its excellent efficiency and average flow resistance. The better performance of the ACE3 column was due to its better packing quality, as could be derived from its impedance plot. Kinetic plots of resolution of a critical pair versus analysis time and column length were established at pH 8.0. These plots can be used as a method development tool to tailor the separation conditions to the required resolution of a given critical pair, combining efficiency and selectivity features of the column. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:3351 / 3359
页数:9
相关论文
共 50 条
  • [1] REVERSED-PHASE C18 HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF ACIDIC AND CONJUGATED GIBBERELLINS
    KOSHIOKA, M
    HARADA, J
    TAKENO, K
    NOMA, M
    SASSA, T
    OGIYAMA, K
    TAYLOR, JS
    ROOD, SB
    LEGGE, RL
    PHARIS, RP
    JOURNAL OF CHROMATOGRAPHY, 1983, 256 (01): : 101 - 115
  • [2] PEPTIDE ANALYSIS USING C18 REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KEMPI, NM
    NAGEL, GM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 31 - CHED
  • [3] PROPYLAMIDO-MODIFIED C18 REVERSED-PHASE FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LIN, JY
    YANG, MH
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1991, 38 (06) : 543 - 548
  • [4] Evaluation and comparison of the kinetic performance of ultra-high performance liquid chromatography and high-performance liquid chromatography columns in hydrophilic interaction and reversed-phase liquid chromatography conditions
    Song, Huiying
    Adams, Erwin
    Desmet, Gert
    Cabooter, Deirdre
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1369 : 83 - 91
  • [5] Reversed-phase high-performance liquid chromatography in grain applications
    Lookhart, GL
    Bean, SR
    Bietz, JA
    CEREAL FOODS WORLD, 2003, 48 (01) : 9 - 16
  • [6] Practical observations on the performance of bare silica in hydrophilic interaction compared with C18 reversed-phase liquid chromatography
    Heaton, James C.
    Wang, Xiaoli
    Barber, William E.
    Buckenmaier, Stephan M. C.
    McCalley, David V.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1328 : 7 - 15
  • [7] Behaviour of proteins on reversed-phase supports during high performance liquid chromatography on C18 stationary phase
    Rotkaja, Oksana
    Golushko, Jelena
    Mekss, Peteris
    PROCEEDINGS OF THE ESTONIAN ACADEMY OF SCIENCES, 2015, 64 (01) : 36 - 42
  • [8] CHEMOMETRIC CLASSIFICATION OF REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS
    DELANEY, MF
    PAPAS, AN
    WALTERS, MJ
    JOURNAL OF CHROMATOGRAPHY, 1987, 410 (01): : 31 - 41
  • [9] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF ANTIBIOTICS ON MICROBORE COLUMNS
    WHITE, ER
    LAUFER, DN
    JOURNAL OF CHROMATOGRAPHY, 1984, 290 (MAY): : 187 - 196
  • [10] DIFFERENCES IN SELECTIVITY OF REVERSED-PHASE COLUMNS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    WOUTERS, I
    HENDRICKX, S
    ROETS, E
    HOOGMARTENS, J
    VANDERHAEGHE, H
    ACS SYMPOSIUM SERIES, 1986, 297 : 68 - 82