A comparison of an optimized automated sample preparation of PEth in blood pretreated by freezing versus manual preparation in whole blood, analyzing by UHPLC - MS/MS

被引:2
|
作者
Muller, Lill Dannevig [1 ]
Foreid, Siri [1 ]
机构
[1] Oslo Univ Hosp, Dept Pharmacol, Sect Clin Pharmacol, N-0424 Oslo, Norway
关键词
PEth; Whole blood; Automatic sample preparation; Optimising; 96-well plate; UHPLC-MS/MS; BIOMARKER PHOSPHATIDYLETHANOL; RAT ORGANS; ALCOHOL; CONSUMPTION; MARKER;
D O I
10.1016/j.jpba.2022.114635
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A robust and simple high-throughput automatic sample preparation in a 96-well plate format for quantification of PEth16:0/18:1 with UHPLC-MS/MS in pre-treated frozen blood samples has been simplified as well as optimised regarding liquid handling parameters. To keep the air cushion in the pipetting step as small as possible, 300 pipette tips were used instead of 1000 mu l tips for pipetting the minimum volume of 2-propanol required for the sample preparation. The 96-well plate was mixed vigorously to acquire a good reproducibility of the PEth results. A 96-wellplate with a well volume of 2.0 ml was used to eliminate cross contamination between the wells, and the calibration curve covered a concentration range from 0.03 to 5 mu mol/l. The method was sensitive, and the limit of quantification was 0.005 mu mol/l for PEth. The matrix effect in whole blood was small and corrected to 106% by using an isotope-labelled internal standard. There was no carry-over observed after the highest standard 5 mu mol/l. The intermediate precision and accuracy were, respectively, less than 9% and 101% when using both the automated and manual sample preparation method. 19 external controls were analysed from an Equalis proficiency testing program for a period of 16 months, and our results were always within 79% of the assigned value. 114 samples were analysed by manual and automatic sample preparation with UHPLC-MS/MS in respectively whole blood and pre-treated frozen blood samples. The mean percentage difference of these measurements between the two methods was calculated in accordance with (Bland & Altman) to be (-4.8 +/- 5.6) %.
引用
收藏
页数:9
相关论文
共 48 条
  • [1] Comparison of sample preparation methods, validation of an UPLC-MS/MS procedure for the quantification of cyclosporine A in whole blood sample
    Wu, Lingjie
    Ye, Zhenjie
    Zhang, Xiaoying
    Cheng, Yu
    Zheng, Ling
    Qiu, Hongqiang
    Liu, Xiaolong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 193
  • [2] Development of an LC-MS/MS assay with automated sample preparation for phosphatidylethanol (PEth)- Not your typical clinical marker
    Lahr, Richard G.
    Sharma, Pragya
    Maus, Anthony
    Langman, Loralie J.
    Jannetto, Paul J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1229
  • [3] Validation of a dried blood spot LC-MS/MS approach for cyclosporin A in cat blood: Comparison with a classical sample preparation
    Mohamed, Rayane
    Mercolini, Laura
    Cuennet-Cosandey, Suzanne
    Chavent, Jacques
    Raggi, Maria Augusta
    Peyrou, Mathieu
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 298 - 305
  • [4] QuEChERS sample preparation prior to LC-MS/MS determination of opiates, amphetamines, and cocaine metabolites in whole blood
    Dulaurent, Sylvain
    El Balkhi, Souleiman
    Poncelet, Lauranne
    Gaulier, Jean-Michel
    Marquet, Pierre
    Saint-Marcoux, Franck
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (05) : 1467 - 1474
  • [5] QuEChERS sample preparation prior to LC-MS/MS determination of opiates, amphetamines, and cocaine metabolites in whole blood
    Sylvain Dulaurent
    Souleiman El Balkhi
    Lauranne Poncelet
    Jean-Michel Gaulier
    Pierre Marquet
    Franck Saint-Marcoux
    Analytical and Bioanalytical Chemistry, 2016, 408 : 1467 - 1474
  • [6] Validation and evaluation of four sample preparation methods for the quantification of intracellular tacrolimus in peripheral blood mononuclear cells by UHPLC-MS/MS
    van Merendonk, Lisanne N.
    Fontova, Pere
    Rigo-Bonnin, Raul
    Colom, Helena
    Vidal-Alabro, Anna
    Bestard, Oriol
    Torras, Juan
    Cruzado, Josep M.
    Grinyo, Josep M.
    Lloberas, Nuria
    CLINICA CHIMICA ACTA, 2020, 503 : 210 - 217
  • [7] Automated sample preparation and fast GC–MS determination of fatty acids in blood samples and dietary supplements
    Antonio Ferracane
    Ivan Aloisi
    Micaela Galletta
    Mariosimone Zoccali
    Peter Q. Tranchida
    Giuseppe Micalizzi
    Luigi Mondello
    Analytical and Bioanalytical Chemistry, 2022, 414 : 8423 - 8435
  • [8] Comparison of blood plasma sample preparation methods for combined LC-MS lipidomics and metabolomics
    Patterson, Rainey E.
    Ducrocq, Antoine J.
    McDougall, Danielle J.
    Garrett, Timothy J.
    Yost, Richard A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1002 : 260 - 266
  • [9] Manual punch versus automated flow-through sample desorption for dried blood spot LC-MS/MS analysis of voriconazole
    Martial, Lisa C.
    van den Hombergh, Erik
    Tump, Cornelis
    Halmingh, Otto
    Burger, David M.
    van Maarseveen, Erik M.
    Bruggemann, Roger J.
    Aarnoutse, Rob E.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1089 : 16 - 23
  • [10] Validation of a Fully Automated Robotic Setup for Preparation of Whole Blood Samples for LC-MS Toxicology Analysis
    Andersen, David
    Rasmussen, Brian
    Linnet, Kristian
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2012, 36 (04) : 280 - 287