High-throughput fluorescence flow-injection topoisomerase II inhibition assay

被引:9
|
作者
Barnabé, N [1 ]
Hasinoff, BB [1 ]
机构
[1] Univ Manitoba, Fac Pharm, Winnipeg, MB R3T 2N2, Canada
基金
加拿大健康研究院;
关键词
flow-injection analysis; topoisomerase H;
D O I
10.1016/S0378-4347(01)00274-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-throughput fluorescence flow-injection assay is described, suitable for determining the catalytic inhibition of DNA topoisomerase II. The method, which separates high molecular mass trypanosome kinetoplast DNA from its decatenated product by centrifugation, should be useful for the rapid and accurate screening of potential anticancer topoisomerase II inhibitors and the determination of their inhibition constants. Advantages of the flow-injection method over agarose gel electrophoresis and radioactive centrifugation assays are that it is faster, more sensitive, highly linear in its response to product formation, and does not require the production of radioactive trypanosome kinetoplast DNA substrate. (C) 2001 Elsevier Science BY All rights reserved.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 50 条
  • [1] Fluorescence assay for HERG inhibition and high-throughput compound profiling for safety
    Zlokarnik, G
    Shah, U
    Fischer, A
    Oades, K
    Numann, R
    DRUG METABOLISM REVIEWS, 2002, 34 : 205 - 205
  • [2] High-throughput flow-injection technique for stability sensing characterization of biomolecules in solution
    Helfrich, JP
    Jones, WR
    AMERICAN LABORATORY, 2001, 33 (14) : 24 - +
  • [3] Ribonuclease activity of vaccinia DNA topoisomerase IB: Kinetic and high-throughput inhibition studies using a robust continuous fluorescence assay
    Kwon, K
    Nagarajan, R
    Stivers, JT
    BIOCHEMISTRY, 2004, 43 (47) : 14994 - 15004
  • [4] Evaluation of a high-throughput fluorescence assay method for hERG potassium channel inhibition
    Dorn, A
    Hermann, F
    Ebneth, A
    Bothmann, H
    Trube, G
    Christensen, K
    Apfel, C
    JOURNAL OF BIOMOLECULAR SCREENING, 2005, 10 (04) : 339 - 347
  • [5] A high-throughput fluorescence anisotropy-based assay for human topoisomerase II β-catalyzed ATP-dependent supercoiled DNA relaxation
    Shapiro, Adam B.
    Austin, Caroline A.
    ANALYTICAL BIOCHEMISTRY, 2014, 448 : 23 - 29
  • [6] A high-throughput biliverdin assay using infrared fluorescence
    Berlec, Ales
    Strukelj, Borut
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2014, 26 (04) : 521 - 526
  • [7] High-throughput sequential injection assay method for chlorpromazine
    Naheid, S.A., 1600, Maik Nauka Publishing / Springer SBM (68):
  • [8] High-throughput sequential injection assay method for chlorpromazine
    Naheid, Salih A.
    Idris, Abubakr M.
    Elgorashe, Rafea E. E.
    Altayeb, Mohammed A. H.
    Alnajjar, Ahmed O.
    Assubaie, Fahad N.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (03) : 233 - 240
  • [9] High-throughput sequential injection assay method for chlorpromazine
    Salih A. Naheid
    Abubakr M. Idris
    Rafea E. E. Elgorashe
    Mohammed A. H. Altayeb
    Ahmed O. Alnajjar
    Fahad N. Assubaie
    Journal of Analytical Chemistry, 2013, 68 : 233 - 240
  • [10] Development of a Thyroperoxidase Inhibition Assay for High-Throughput Screening
    Paul, Katie B.
    Hedge, Joan M.
    Rotroff, Daniel M.
    Hornung, Michael W.
    Crofton, Kevin M.
    Simmons, Steven O.
    CHEMICAL RESEARCH IN TOXICOLOGY, 2014, 27 (03) : 387 - 399