Implantable cardioverter defibrillator in a child using a single subcutaneous array lead and an abdominal active can

被引:22
|
作者
Luedemann, M [1 ]
Hund, K [1 ]
Stertmann, W [1 ]
Michel-Behnke, I [1 ]
Gonzales, M [1 ]
Akintuerk, H [1 ]
Schranz, D [1 ]
机构
[1] Univ Giessen, Pediat Heart Ctr, D-35385 Giessen, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2004年 / 27卷 / 01期
关键词
ICD; defibrillator; children; subcutaneous array lead; nonthoracotomy;
D O I
10.1111/j.1540-8159.2004.00398.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This report describes the case of an 8-year-old boy with hypertrophic cardiomyopathy (HCM) who underwent ICD implantation for recurrent syncope. To avoid vascular complications and to minimize the surgical approach in this small child, a nonthoracotomy ICD system was chosen using a single subcutaneous array lead with only one finger, an abdominally placed active can, and epicardial dual chamber pacing and sensing electrodes. During an 8-month follow-up, DFT was confirmed and there were no ventricular tachycardia or complications. It appears to be a safe device for the prevention of sudden cardiac death in infants and small children.
引用
收藏
页码:117 / 119
页数:3
相关论文
共 50 条
  • [1] Defibrillation efficacy comparing a subcutaneous array electrode versus an "active can" implantable cardioverter defibrillator and a subcutaneous array electrode in addition to an "active can" implantable cardioverter defibrillator:: Results from active can versus array trials I and II
    Gradaus, R
    Block, M
    Seidl, K
    Brunn, J
    Isgro, F
    Hammel, D
    Hauer, B
    Breithardt, G
    Böcker, D
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (08) : 921 - 927
  • [2] Subcutaneous implantable cardioverter defibrillator lead displacement
    Vyas, Sandip
    Monkhouse, Christopher
    Srinivasan, Neil
    Lambiase, Pier D.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (04): : 723 - 725
  • [3] Abdominal submuscular implant of subcutaneous implantable cardioverter-defibrillator in a young child
    Kwok, Sit-Yee
    Yam, Nicholson
    Lun, Kin-Shing
    Chen, Robin Hs
    Au, Timmy Wk
    Yung, Tak-Cheung
    EUROPACE, 2018, 20 : F248 - F248
  • [4] Growth and the subcutaneous implantable cardioverter defibrillator in a small child
    Spentzou, Georgia
    McLean, Andrew
    McLeod, Karen
    CARDIOLOGY IN THE YOUNG, 2019, 29 (12) : 1524 - 1524
  • [5] Single-finger subcutaneous defibrillation lead and "active can": A novel minimally invasive defibrillation configuration for implantable cardioverter-defibrillator implantation in a young child
    Madan, N
    Gaynor, JW
    Tanel, R
    Cohen, M
    Nicholson, S
    Vetter, V
    Rhodes, L
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (05): : 1657 - 1659
  • [6] 12-Lead Electrocardiograms Can Be Reconstructed Using the 3 Electrodes of a Subcutaneous Implantable Cardioverter Defibrillator
    Cronbach, Peter L.
    Wilson, David G.
    Greenhut, Saul E.
    Stegemann, Berthold
    Panfilo, Daniele
    Morgan, John M.
    CIRCULATION, 2015, 132
  • [7] Subcutaneous Implantable Cardioverter Defibrillator
    Rowley, Christopher P.
    Gold, Michael R.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (03): : 587 - 593
  • [8] The Subcutaneous Implantable Cardioverter Defibrillator
    Steffel, Jan
    EUROPEAN HEART JOURNAL, 2017, 38 (04) : 226 - 228
  • [9] The Subcutaneous Implantable Cardioverter Defibrillator
    Mangels, Daniel
    Frishman, William H.
    CARDIOLOGY IN REVIEW, 2016, 24 (05) : 248 - 255
  • [10] Lead failure in an entirely subcutaneous implantable cardioverter-defibrillator
    Kolb, Christof
    Weigand, Severin
    Schaarschmidt, Claudia
    Lennerz, Carsten
    EUROPACE, 2020, 22 (02): : 183 - 183