Absent middle cerebral artery signal in transcranial color-coded sonography: A reliable indicator of occlusion?

被引:10
|
作者
Chen, YC
Chen, ST
Chen, CJ
Lee, TH [1 ]
机构
[1] Chang Gung Mem Hosp, Dept Neurol, Linkou Med Ctr, Taoyuan 333, Taiwan
[2] I Shou Univ, E Da Hosp, Dept Neuroradiol, Kaohsiung, Taiwan
关键词
ultrasonography; transcranial Doppler; transcranial color-coded sonography; middle cerebral artery; occlusion; cerebral angiography;
D O I
10.1159/000087707
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Assess the accuracy of transcranial color-coded sonography (TCCS) for detecting middle cerebral artery (MCA) stem occlusion and compare it with cerebral angiography. Methods: This study enrolled a series of patients who received TCCS and cerebral angiography at the Department of Neurology in Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan, between January 1997 and July 2003. MCA stem occlusion was diagnosed based on digital subtraction angiography and/or computed tomographic angiography. The effect of the supplying artery on the insonation of MCA stem was considered. The sonographic criteria for MCA stem occlusion were defined as absent MCA stem signal+visible signal on the reference arteries, including ipsilateral posterior cerebral artery, ipsilateral anterior cerebral artery or contralateral MCA stem. Results: A total of 419 consecutive patients were enrolled. Factors that significantly influenced MCA stem insonation included >= 50% ipsilateral carotid artery stenosis, >= 50% MCA stem stenosis, female gender, and age >= 60 years. Comparing patients with <50% and those with >= 50% carotid stenosis, the MCA stem insonation rate was significantly reduced from 69.1% to 45.6% (p<0.001). In patients with <50% ipsilateral carotid artery stenosis, the sonographic criteria had a positive predictive value of 10.5% and a negative predictive value of 98.9%, and could predict MCA stem occlusion with high specificity but low sensitivity (specificity=89.6, sensitivity=54.5, overall accuracy=88.9, p<0.001). Conclusion: Absent MCA stem signal may result from MCA stem occlusion/tight stenosis and tight stenosis of ipsilateral carotid arteries, and has a limited value in detecting MCA stem occlusion. TCCS can be useful in identifying nonoccluded MCA stem, and cerebral angiography is necessary to confirm MCA stem occlusion. Copyright (C) 2005 S. Karger AG, Basel.
引用
收藏
页码:251 / 257
页数:7
相关论文
共 50 条
  • [2] Diagnosis of middle cerebral artery occlusion with transcranial color-coded real-time sonography
    Kimura, K
    Hashimoto, Y
    Hirano, T
    Uchino, M
    Ando, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (05) : 895 - 899
  • [3] Transcranial color-coded sonography for the detection of middle cerebral artery stenosis
    Tang, SC
    Jeng, JS
    Yip, PK
    Lu, CJ
    Hwang, BS
    Lin, WH
    Liu, HM
    JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (04) : 451 - 457
  • [4] Evaluation of Transcranial Color-Coded Duplex Sonography for Cerebral Artery Stenosis or Occlusion
    Hou, Wei Hua
    Liu, Xi
    Duan, Yun You
    Wang, Jia
    Sun, Si Guo
    Deng, Jian Ping
    Qin, Huai Zhou
    Cao, Tie Sheng
    CEREBROVASCULAR DISEASES, 2009, 27 (05) : 479 - 484
  • [5] Visibility of the Lesser Sphenoid Wing Is an Important Indicator for Detecting the Middle Cerebral Artery on Transcranial Color-Coded Sonography
    Suzuki, Rieko
    Koga, Masatoshi
    Mori, Mayumi
    Endo, Kaoru
    Toyoda, Kazunori
    Minematsu, Kazuo
    CEREBROVASCULAR DISEASES, 2012, 33 (03) : 272 - 279
  • [6] Middle Cerebral Artery Dissection Diagnostic and Prognostic Value of Transcranial Color-Coded Sonography
    Barroso, Bruno
    Demasles, Stephanie
    Bertandeau, Eric
    Bonnan, Mikael
    Miquel, Marie
    Krim, Elsa
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (07) : 1293 - 1297
  • [7] Stenosis in Middle Cerebral Artery Duplication Assessment With Transcranial Color-Coded Duplex Sonography
    Gomez-Choco, Manuel
    Nedelmann, Max
    Valdueza, Jose M.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (09) : 2053 - 2056
  • [8] Continuous Monitoring of Middle Cerebral Artery Recanalization with Transcranial Color-Coded Sonography and Levovist
    Alain Viguier
    Raphael Petit
    Mathieu Rigal
    Pascal Cintas
    Vincent Larrue
    Journal of Thrombosis and Thrombolysis, 2005, 19 : 55 - 59
  • [9] Continuous monitoring of middle cerebral artery recanalization with transcranial color-coded sonography and Levovist
    Viguier, A
    Petit, R
    Rigal, M
    Cintas, P
    Larrue, V
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2005, 19 (01) : 55 - 59
  • [10] TRANSCRANIAL COLOR-CODED SONOGRAPHY CRITERIA FOR MODERATE AND SEVERE MIDDLE CEREBRAL ARTERY STENOSIS
    Liu, Ran
    Li, Jingzhi
    Hua, Yang
    Yang, Jie
    Zhao, Yue
    Tian, Xiaojie
    Ma, Yan
    Zhao, Wenbo
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (01): : 25 - 32