摘要
Whole blood has been found to be a reliable matrix for the detection and quantitation of cytornegalovirus (CW) DNA. In this study, the performance of the artus CMV LightCycler (LQ PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-hlood samples were investigated, and results were compared with those obtained with the in vitro diagnostics JVD)/Conformite Europ6ene (CE)-labeled CNIV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within +/- 0.5 log(10) unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CNW LC PCR kit in conjunction with automated sample preparation on the BioRobot EZI workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay.
引用
收藏
页码:1241 / 1245
页数:5
相关论文
共 13 条
  • [1] Detection and quantitation of cytomegalovirus(CMV)DNA in EDTA whole blood samples by automated extraction and real-time PCR
    Michelin, B. D. A.
    Bozic, M.
    Hammerschmidt, S.
    Homberg, C.
    Violan, D.
    Kessler, H. H.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2009, 46 : S50 - S50
  • [2] Prediction of cytomegalovirus (CMV) plasma load from evaluation of CMV whole-blood load in samples from renal transplant recipientsv
    Garrigue, Isabelle
    Doussau, Adelaide
    Asselineau, Julien
    Bricout, Helene
    Couzi, Lionel
    Rio, Catherine
    Merville, Pierre
    Fleury, Herve
    Lafon, Marie-Edith
    Thiebaut, Rodolphe
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (02) : 493 - 498
  • [3] Evaluation of an automated and highly sensitive real-time PCR assay for CMV DNA in whole blood samples
    Deback, C.
    Akhavan, S.
    Blanc-Perrel, S.
    Dupuis, F.
    Schaffer, S.
    Thamm, S.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2006, 36 : S26 - S26
  • [4] Performance Evaluation of the Real-Q Cytomegalovirus (CMV) Quantification Kit Using Two Real-Time PCR Systems for Quantifying CMV DNA in Whole Blood
    Park, Jong Eun
    Kim, Ji-Youn
    Yun, Sun Ae
    Lee, Myoung-Keun
    Huh, Hee Jae
    Kim, Jong-Won
    Ki, Chang-Seok
    [J]. ANNALS OF LABORATORY MEDICINE, 2016, 36 (06) : 603 - 606
  • [5] Evaluation of the H-DiaCMVQ kit® for detecting and quantifying CMV-DNA in plasma and in whole blood samples
    Mengelle, Catherine
    Mansuy, Jean-Michel
    Houles, Laeitita
    Sandres-Saune, Karine
    Izopet, Jacques
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2016, 82 : S48 - S49
  • [6] Detection and quantitation of Epstein-Barr virus (EBV) DNA in EDTA whole blood samples using automated sample preparation and real time PCR
    Raggam, Reinhard B.
    Wagner, Jasmin
    Bozic, Michael
    Michelin, Birgit D. A.
    Hammerschmidt, Sandra
    Homberg, Cordula
    Kessler, Harald H.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (03) : 413 - 418
  • [7] DETECTION OF CYTOMEGALOVIRUS (CMV) IN SEROPOSITIVE BLOOD-DONORS BY POLYMERASE CHAIN-REACTION (PCR) - EFFECT OF SAMPLE PREPARATION
    LAU, W
    HERST, R
    SHANKARAN, P
    KRAJDEN, M
    [J]. TRANSFUSION, 1995, 35 (10) : S133 - S133
  • [8] Evaluation of a standardised real-time PCR based DNA-detection method (Realstar®) in whole blood for the diagnosis of primary human cytomegalovirus (CMV) infections in immunocompetent patients
    M. Berth
    I. Benoy
    N. Christensen
    [J]. European Journal of Clinical Microbiology & Infectious Diseases, 2016, 35 : 245 - 249
  • [9] Evaluation of a standardised real-time PCR based DNA-detection method (Realstar®) in whole blood for the diagnosis of primary human cytomegalovirus (CMV) infections in immunocompetent patients
    Berth, M.
    Benoy, I.
    Christensen, N.
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2016, 35 (02) : 245 - 249
  • [10] Rapid quantitation of cytomegalovirus DNA in whole blood by a new molecular assay based on automated sample preparation and real-time PCR
    Reinhard B. Raggam
    Michael Bozic
    Helmut J. F. Salzer
    Sandra Hammerschmidt
    Cordula Homberg
    Katharina Ruzicka
    Harald H. Kessler
    [J]. Medical Microbiology and Immunology, 2010, 199 : 311 - 316