Preparation of 90YCl3 radiopharmaceutical precursor for nuclear medicine using technology of centrifugal extractors

被引:8
|
作者
Srank, J. [1 ,3 ]
Melichar, F. [1 ,3 ]
Filyanin, A. T. [2 ]
Tomes, M. [1 ,3 ]
Beran, M. [1 ,3 ]
机构
[1] ASCR, Inst Nucl Phys, Publ Res Inst, Radiopharmaceut Dept, Rez 25068, Czech Republic
[2] Russian Acad Sci, Inst Phys Chem & Electrochem, Moscow, Russia
[3] RadioMedic Ltd, Rez 25068, Czech Republic
关键词
Y-90 radionuclide precursor; Extraction separation; Centrifugal extractors; Product purity; Analytical control; CARRIER-FREE Y-90; SEPARATION;
D O I
10.1016/j.apradiso.2010.07.012
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Separation of Y-90 from a parent solution of Sr-90-Y-90 in 05 M nitric acid by two-stage liquid-liquid extraction has been investigated using centrifugal extractors. The extraction agent used was 0.25 M di(2-ethylhexyl)phosphoric acid (D2EHPA) in n-dodecane. Back-extraction used 5 M HCl Evaporation of HCl was performed in a rotary vacuum evaporator. Experience gained during the design, construction and running of more than 100 hot separations is presented A short description of analytical methods used and results of the determination of chemical, radionuclidic and radiochemical purities and sterility are given. (C) 2010 Elsevier Ltd All rights reserved.
引用
收藏
页码:2163 / 2168
页数:6
相关论文
共 5 条
  • [1] Quality Control of the Radiopharmaceutical Precursor ItraPol (90YCl3) Produced at POLATOM
    Garnuszek, P.
    Pawlak, D.
    Dziel, T.
    Filiks, A.
    Sasinowska, I.
    Maurin, M.
    Korytkowski, M.
    Mikolajczak, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S413 - S414
  • [2] Method for 90Sr determination in 90YCl3 solution used as precursor for labeling
    Pawlak, D. W.
    Parus, J. L.
    Korsak, A.
    Dziel, T.
    Muklanowicz, A.
    Mikolajczak, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S416 - S416
  • [3] Quality control of no-carrier-added 90YCl3 by estimating the labeling efficiency using its reaction with DOTATOC
    Henke, K. Eigner
    Beran, M.
    Srank, J.
    Melichar, F.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 278 (01) : 25 - 29
  • [4] Quality control of no-carrier-added 90YCl3 by estimating the labeling efficiency using its reaction with DOTATOC
    K. Eigner Henke
    M. Beran
    J. Srank
    F. Melichar
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 : 25 - 29
  • [5] Investigation of a Nuclear Medicine Compton Camera for low dose imaging using Timepix3 technology
    Cournane, S.
    Kamtchou, B.
    McNulty, R.
    Vintro, L. Leon
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S288 - S288