Validation of an accelerated 'demons' algorithm for deformable image registration in radiation therapy

被引:478
|
作者
Wang, H
Dong, L
O'Daniel, J
Mohan, R
Garden, AS
Ang, KK
Kuban, DA
Bonnen, M
Chang, JY
Cheung, R
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 12期
关键词
D O I
10.1088/0031-9155/50/12/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A greyscale-based fully automatic deformable image registration algorithm, originally known as the 'demons' algorithm, was implemented for CT image-guided radiotherapy. We accelerated the algorithm by introducing an 'active force' along with an adaptive force strength adjustment during the iterative process. These improvements led to a 40% speed improvement over the original algorithm and a high tolerance of large organ deformations. We used three methods to evaluate the accuracy of the algorithm. First, we created a set of mathematical transformations for a series of patient's CT images. This provides a 'ground truth' solution for quantitatively validating the deformable image registration algorithm. Second, we used a physically deformable pelvic phantom, which can measure deformed objects under different conditions. The results of these two tests allowed us to quantify the accuracy of the deformable registration. Validation results showed that more than 96% of the voxels were within 2 mm of their intended shifts for a prostate and a head-and-neck patient case. The mean errors and standard deviations were 0.5 mm 1.5 mm and 0.2 mm +/- 0.6 mm, respectively. Using the deformable pelvis phantom, the result showed a tracking accuracy of better than 1.5 mm for 23 seeds implanted in a phantom prostate that was deformed by inflation of a rectal balloon. Third, physician-drawn contours outlining the tumour volumes and certain anatomical structures in the original CT images were deformed along with the CT images acquired during subsequent treatments or during a different respiratory phase for a lung cancer case. Visual inspection of the positions and shapes of these deformed contours agreed well with human judgment. Together, these results suggest that the accelerated demons algorithm has significant potential for delineating and tracking doses in targets and critical structures during CT-guided radiotherapy.
引用
收藏
页码:2887 / 2905
页数:19
相关论文
共 50 条
  • [1] Validation of an Improved 'Diffeomorphic Demons' Algorithm for Deformable Image Registration in Image-Guided Radiation Therapy
    Zhou, Lu
    Zhou, Linghong
    Zhang, Shuxu
    Zhen, Xin
    Yu, Hui
    Zhang, Guoqian
    Wang, Ruihao
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 373 - 382
  • [2] Deformable image registration in radiation therapy
    Dowling, Jason A.
    O'Connor, Laura M.
    [J]. JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (04) : 257 - 259
  • [3] DEFORMABLE IMAGE REGISTRATION FOR RADIATION THERAPY
    Sarrut, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S47 - S47
  • [4] A Novel Deformable Image Registration Algorithm Based on Improved Active Demons
    Zhuang, Shiyong
    Xia, Youshen
    [J]. 2017 10TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI), 2017,
  • [5] A REGISTRATION ALGORITHM FOR DOSE CORRECTION IN RADIATION THERAPY - VALIDATION OF DEFORMABLE REGISTRATION USING PHANTOMS.
    Zambrano, V.
    Fabri, D.
    Stock, M.
    Brikfellner, W.
    Georg, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S59 - S60
  • [6] A Contour-guided Demons Deformable Image Registration Algorithm For Adaptive Radiotherapy
    Gu, X.
    Jia, X.
    Dong, B.
    Gautier, Q.
    Jiang, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S803 - S804
  • [7] Evaluation of Diffeomorphic Demons Algorithm for Deformable Image Registration Using Virtual Phantom
    Reiazi, R.
    Mohammadi, R.
    Mahdavi, S. R.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E228 - E228
  • [8] An anthropomorphic abdominal phantom for deformable image registration accuracy validation in adaptive radiation therapy
    Liao, Yuliang
    Wang, Linjing
    Xu, Xiangdong
    Chen, Haibin
    Chen, Jiawei
    Zhang, Guoqian
    Lei, Huaiyu
    Wang, Ruihao
    Zhang, Shuxu
    Gu, Xuejun
    Zhen, Xin
    Zhou, Linghong
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2369 - 2378
  • [9] Patient-specific validation of deformable image registration in radiation therapy: Overview and caveats
    Paganelli, Chiara
    Meschini, Giorgia
    Molinelli, Silvia
    Riboldi, Marco
    Baroni, Guido
    [J]. MEDICAL PHYSICS, 2018, 45 (10) : E908 - E922
  • [10] Deformable registration for image-guided radiation therapy
    Sarrut, David