Pressure fluctuation is the primary reason for unstable operations of double-suction centrifugal pumps. By using flush mounted pressure transducers in the semispiral suction chamber and the volute casing of a double-suction pump, the pressure fluctuation signals were obtained and recorded at various operating conditions. Spectral analyses were performed on the pressure fluctuation signals in both frequency domain and time-frequency domain based on fast Fourier transform (FFT) and an adaptive optimal-kernel time-frequency representation (AOK TFR). The results show that pressure fluctuations at the impeller rotating frequency and some lower frequencies dominated in the semispiral suction chamber. Pressure fluctuations at the blade passing frequency, the impeller rotating frequency, and their harmonic frequencies were identified in the volute casing. The amplitude of pressure fluctuation at the blade passing frequency significantly increased when the flow rate deviated from the design flow rate. At 107% of the design flow rate, the amplitude increased more than 254% than that at the design flow rate. The time-frequency characteristics of these pressure fluctuations were affected greatly by both operating conditions and measurement locations. At partial flow rates the pulsation had a great irregularity and the amplitudes at the investigated frequencies were much larger than ones at the design flow rate. An asymmetrical pressure fluctuation structure in the volute casing was observed at all flow rates. The pulsation behavior at the blade passing frequency was the most prominent near the volute tongue zone, and the pressure waves propagated in both the radial and circumferential directions. [DOI: 10.1115/1.4004959]
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Experimental investigation on pressure fluctuations in suction chamber and volute of a double-suction centrifugal pump
    Yao, Zhi-Feng
    Wang, Fu-Jun
    Xiao, Ruo-Fu
    He, Cheng-Lian
    Shuili Xuebao/Journal of Hydraulic Engineering, 2012, 43 (04): : 473 - 479
  • [2] Experimental investigation of pressure instabilities affected by cavitation for a double-suction centrifugal pump
    Yao, Z. F.
    Wang, F. J.
    Xiao, R. F.
    He, C. L.
    26TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, PTS 1-7, 2013, 15
  • [3] Investigation on Reduction of Pressure Fluctuation for a Double-Suction Centrifugal Pump
    Qianqian Li
    Shiyang Li
    Peng Wu
    Bin Huang
    Dazhuan Wu
    Chinese Journal of Mechanical Engineering, 2021, 34
  • [4] Effects of impeller type on pressure fluctuations in double-suction centrifugal pump
    Yao Z.
    Wang F.
    Yang M.
    Qu L.
    Xiao R.
    Xu X.
    He C.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2011, 47 (12): : 133 - 137+143
  • [5] Investigation on Reduction of Pressure Fluctuation for a Double-Suction Centrifugal Pump
    Qianqian Li
    Shiyang Li
    Peng Wu
    Bin Huang
    Dazhuan Wu
    Chinese Journal of Mechanical Engineering, 2021, 34 (01) : 192 - 209
  • [6] Effect of inlet splitter on pressure fluctuations in a double-suction centrifugal pump
    Liu, Houlin
    Luo, Kaikai
    Wu, Xianfang
    Chen, Huilong
    Wang, Kai
    JOURNAL OF VIBROENGINEERING, 2017, 19 (01) : 549 - 562
  • [7] Investigation on Reduction of Pressure Fluctuation for a Double-Suction Centrifugal Pump
    Li, Qianqian
    Li, Shiyang
    Wu, Peng
    Huang, Bin
    Wu, Dazhuan
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2021, 34 (01)
  • [8] Numerical investigation of unsteady pressure fluctuations near volute tongue in a double-suction centrifugal pump
    Cong, Guohui
    Wang, Fujun
    Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2008, 39 (06): : 60 - 63
  • [9] Effects of flow rate and rotational speed on pressure fluctuations in a double-suction centrifugal pump
    Wang, Zhiyuan
    Qian, Zhongdong
    Lu, Jie
    Wu, Pengfei
    ENERGY, 2019, 170 : 212 - 227
  • [10] Numerical simulation and tests for pressure fluctuation characteristics in a double-suction centrifugal pump
    Wang W.
    Deng Q.
    Pei J.
    Yuan S.
    Zhang B.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2020, 39 (19): : 107 - 113and120