Effect of bevel direction on the success rate of ultrasound-guided radial arterial catheterization

被引:9
|
作者
Min, Sung-Won [2 ]
Cho, Hyong-Rae [3 ]
Jeon, Young-Tae [4 ]
Oh, Ah-Young [4 ]
Park, Hee-Pyoung [5 ]
Yang, Chun Woo [1 ]
Choi, Woo Hee [1 ]
Kim, Byung-Gun [1 ]
机构
[1] Inha Univ, Inha Univ Hosp, Sch Med, Dept Anesthesiol & Pain Med, Sinheung Dong 3 Ga, Inchon 400711, South Korea
[2] SMG SNU Boramae Med Ctr, Dept Anesthesiol & Pain Med, Seoul, South Korea
[3] Myongji Hosp, Dept Anesthesiol & Pain Med, Goyang, South Korea
[4] Seoul Natl Univ, Bundang Hosp, Dept Anesthesiol & Pain Med, Songnam, South Korea
[5] Seoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Dept Anesthesiol & Pain Med, Seoul, South Korea
来源
BMC ANESTHESIOLOGY | 2016年 / 16卷
关键词
CANNULATION; PUNCTURE; PLANE;
D O I
10.1186/s12871-016-0202-5
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: This study assessed the effect of bevel direction on the success rate of ultrasound guided radial artery catheterization. Methods: A total of 204 patients requiring radial artery catheterization were randomly divided into bevel-up (n = 102) and bevel-down (n = 102) groups. Success rate, cannulation time, and number of attempts were compared groups. Results: In the bevel-down group, an arterial line was placed on the first attempt in 86 of 102 (84.3 %; 95 % confidence interval [CI] = 76 % to 90 %) patients versus 73 of 102 (71.6 %; 95 % CI = 62.1 % to 79.4 %) in the bevel-up group (p = 0. 028). In the bevel-down group, the mean time to a successful radial arterial cannulation was 33.3 +/- 6.3 seconds (95 % CI = 32.1-34.6) versus 35.9 +/- 7.6 seconds (95 % CI = 34.4-37.2) in the bevel-up group (p = 0.011). The median score was 33.2 and interquartile range [IQR] was 10.9 (30.3-41.2) for the mean cannulation time in the bevel-up group. In the bevel-down group, the mean score was 32.3 (IQR 3.90, 30-33.9) for mean cannulation time. In the bevel-down group, 11 of 102 (7 %; 95 % CI = 0 to 16 %) patients developed a posterior wall puncture versus 22 of 102 ((21.6 %; 95 % CI = 14.7 to 17.2 %) in the bevel-up group. Conclusion: The bevel-down approach during ultrasound-guided radial artery catheterization exhibited a higher success with fewer complications compared to the bevel-up approach.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Effect of bevel direction on the success rate of ultrasound-guided radial arterial catheterization
    Sung-Won Min
    Hyong-Rae Cho
    Young-Tae Jeon
    Ah-Young Oh
    Hee-Pyoung Park
    Chun Woo Yang
    Woo Hee Choi
    Byung-Gun Kim
    [J]. BMC Anesthesiology, 16
  • [2] Ultrasound-guided arterial cannulation in infants improves success rate
    Schwemmer, U.
    Arzet, H. A.
    Trautner, H.
    Rauch, S.
    Roewer, N.
    Greim, C. -A.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (06) : 476 - 480
  • [3] Arterial insertion method: A new method for systematic evaluation of ultrasound-guided radial arterial catheterization
    Bardin-Spencer, Amy J.
    Spencer, Timothy R.
    [J]. JOURNAL OF VASCULAR ACCESS, 2021, 22 (05): : 733 - 738
  • [4] Ultrasound-guided arterial catheterization: a narrative review
    Ariel L. Shiloh
    Lewis A. Eisen
    [J]. Intensive Care Medicine, 2010, 36 : 214 - 221
  • [5] Anticipating guidelines for ultrasound-guided arterial catheterization
    Kumar, P.
    Cervenka, M.
    Singhal, S.
    Farling, P. A.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (01) : 133 - 134
  • [6] Ultrasound-guided arterial catheterization: a narrative review
    Shiloh, Ariel L.
    Eisen, Lewis A.
    [J]. INTENSIVE CARE MEDICINE, 2010, 36 (02) : 214 - 221
  • [7] Ultrasound-Guided Insertion of a Radial Arterial Catheter
    Ailon, Jonathan
    Mourad, Ophyr
    Chien, Vince
    Saun, Tomas
    Dev, Shelly P.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2014, 371 (15): : E21 - U8
  • [8] Freehand ultrasound-guided femoral arterial catheterization in dogs
    Ringold, Steven A.
    Kelmer, Efrat
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2008, 18 (03) : 306 - 311
  • [9] Ultrasound-Guided Radial Artery Catheterization in Infants and Small Children
    Ishii, Sachiyo
    Shime, Nobuaki
    Shibasaki, Masayuki
    Sawa, Teiji
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2013, 14 (05) : 471 - 473
  • [10] Effect of the bevel direction of puncture needle on success rate and complications during internal jugular vein catheterization
    Lim, Taewan
    Ryu, Ho-Geol
    Jung, Chul-Woo
    Jeon, Yunseok
    Bahk, Jae-Hyon
    [J]. CRITICAL CARE MEDICINE, 2012, 40 (02) : 491 - 494