Fully automated 96-well liquid-liquid extraction for analysis of biological samples by liquid chromatography with tandem mass spectrometry

被引:79
|
作者
Peng, SX [1 ]
Branch, TM [1 ]
King, SL [1 ]
机构
[1] Procter & Gamble Pharmaceut, Hlth Care Res Ctr, Mason, OH 45040 USA
关键词
D O I
10.1021/ac001036c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated high-throughput liquid-liquid extraction (LLE) methodology has been developed for preparation of biological samples using a 96-well LLE plate and a 96-channel robotic liquid handling workstation. The 96-well LLE plate is made of a 96-well filter plate filled with inert diatomaceous earth particles, allowing continuous and efficient extraction of analytes between the aqueous biological sample and the organic extraction solvent. Two carboxylic acid-based protease inhibitor compounds with high and low levels of plasma protein binding were chosen for the development and application of the automated methodology. The LLE extracts of the plasma samples of the two compounds were analyzed by high-performance liquid chromatography with electrospray (ESI) tandem mass spectrometry (LC-MS/MS), The LC-MS/MS method was developed using a rapid gradient LC separation, followed by sample introduction through an ionspray interface in the negative ion mode and tandem mass spectrometric detection with selected reaction monitoring. In the optimized LLE method, a formate buffer solution was first loaded into a 96-well filter plate packed with inert diatomaceous earth material. Then crude plasma samples and a water-immiscible organic solvent, methyl ethyl ketone, were sequentially added to the LLE plate so that LLE would occur in the interface between the two liquid phases on the surface of individual particles in each well. The organic eluate containing extracted analytes was evaporated and reconstituted for LC-MS/MS analysis. This fully automated LLE methodology avoids several disjointed steps involved in a manual or semiautomated LLE method, leading to significantly reduced sample preparation time, increased sample throughput, and clean sample extracts for improved ESI-MS/MS detection. The automated LLE methodology is universal and can be employed for sample preparation of other biological fluids, The complete bioanalytical method, based on the automated LLE and fast gradient LC-IMS/MS, was validated and successfully applied to the quantitative analysis of protease inhibitors in rat plasma.
引用
收藏
页码:708 / 714
页数:7
相关论文
共 50 条
  • [21] A simple 96-well liquid-liquid extraction with a mixture of acetonitrile and methyl t-butyl ether for the determination of a drug in human plasma by high-performance liquid chromatography with tandem mass spectrometry
    Xue, YJ
    Pursley, J
    Arnold, ME
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (02) : 369 - 378
  • [22] Comparison of solid-phase microextraction and liquid-liquid extraction in 96-well format for the determination of a drug compound in human plasma by liquid chromatography with tandem mass spectrometric detection
    Xie, W.
    Pawliszyn, J.
    Mullett, W. M.
    Matuszewski, B. K.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 45 (04) : 599 - 608
  • [23] Determination of carbamazepine in aquatic organisms by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry
    Lajeunesse, Andre
    Vernouillet, Gabrielle
    Eullaffroy, Philippe
    Gagnon, Christian
    Juneau, Philippe
    Sauve, Sebastien
    JOURNAL OF ENVIRONMENTAL MONITORING, 2009, 11 (04): : 723 - 725
  • [24] Quantitative analysis of PD 0332991 in xenograft mouse tumor tissue by a 96-well supported liquid extraction format and liquid chromatography/mass spectrometry
    Nguyen, Leslie
    Zhong, Wei-Zhu
    Painter, Cory L.
    Zhang, Cathy
    Rahavendran, Sadayappan V.
    Shen, Zhongzhou
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 53 (03) : 228 - 234
  • [25] High-Throughput Liquid-Liquid Extraction in 96-Well Format: Parallel Artificial Liquid Membrane Extraction
    Gjelstad, Astrid
    Andresen, Alf Terje
    Dahlgren, Anders
    Gundersen, Thomas E.
    Pedersen-Bjergaard, Stig
    LC GC EUROPE, 2017, 30 (01) : 10 - 17
  • [26] High-Throughput Liquid-Liquid Extraction in 96-Well Format: Parallel Artificial Liquid Membrane Extraction
    Gjelstad, Astrid
    Andresen, Alf Terje
    Dahlgren, Anders
    Gundersen, Thomas E.
    Pedersen-Bjergaard, Stig
    LC GC NORTH AMERICA, 2017, 35 (03) : 192 - 196
  • [27] Method development for comprehensive extraction and analysis of marine toxins: Liquid-liquid extraction and tandem liquid chromatography separations coupled to electrospray tandem mass spectrometry
    Wunschel, David S.
    Valenzuela, Blandina R.
    Kaiser, Brooke L. Deatherage
    Victry, Kristin
    Woodruff, Dana
    TALANTA, 2018, 187 : 302 - 307
  • [28] Fully automated liquid-liquid extraction for the determination of a novel insulin sensitizer in human plasma by heated nebulizer and turbo ionspray liquid chromatography-tandem mass spectrometry
    Riffel, KA
    Groff, MA
    Wenning, L
    Song, HC
    Lo, MW
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (02): : 293 - 300
  • [29] Total plasma homocysteine measured by liquid chromatography-tandem mass spectrometry with use of 96-well plates
    Arndt, T
    Guessregen, B
    Hohl, A
    Heicke, B
    CLINICAL CHEMISTRY, 2004, 50 (04) : 755 - 757
  • [30] Determination of ten monohydroxylated polycyclic aromatic hydrocarbons by liquid-liquid extraction and liquid chromatography/tandem mass spectrometry
    Fan, Ruifang
    Ramage, Robert
    Wang, Dongli
    Zhou, Junqiang
    She, Jianwen
    TALANTA, 2012, 93 : 383 - 391