Characteristics of hylamer polyethylene particles isolated from peri-prosthetic tissues of failed cemented total hip arthroplasties

被引:3
|
作者
Iwakiri, Kentaro [1 ]
Iwaki, Hiroyoshi [1 ]
Kobayashi, Akio [1 ]
Minoda, Yukihide [2 ]
Kagiyama, Hiroshi [3 ]
Kadoya, Yoshinori [4 ]
Takaoka, Kunio [1 ]
机构
[1] Osaka City Univ, Grad Sch Med, Dept Orthopaed Surg, Abeno Ku, Osaka 5458585, Japan
[2] Kansai Rosai Hosp, Dept Orthopaed Surg, Osaka 6600064, Japan
[3] Izumi City Hosp, Dept Orthopaed Surg, Izumi, Osaka 5940071, Japan
[4] Osaka Rosai Hosp, Dept Orthopaed Surg, Sakai, Osaka 5918025, Japan
关键词
hip replacement prosthesis; polyethylene; wear debris; image analysis; microstructure;
D O I
10.1002/jbm.b.30924
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polyethylene wear particles are one of the most important factors affecting the results of total hip arthroplasty. Hylamer, a highly crystalized ultra-high-molecular-weight polyethylene, has been used in total hip arthroplasty for wear reduction, but has exhibited high wear rate and excessive osteolysis. The aim of the present study was to examine Hylamer wear particles in peri-prosthetic tissues with osteolysis obtained from two cases of failed cemented total hip arthroplasty at 8 and 6 years after operation. Polyethylene particles were isolated, and examined using a scanning electron microscope and image analyzer. Total numbers of Hylamer polyethylene particles in the two cases were 5.6 X 10(9) and 8.0 X 10(9) g(-1). Particle sizes (in equivalent circle diameter) for the two cases were 1.07 +/- 0.06 mu m and 1.16 +/- 0.05 mu m, and particle shapes (roundness) were 3.05 +/- 0.22 and 3.76 +/- 0.28. The Hylamer polyethylene particles were larger in size and more elongated and their number was larger, compared with the corresponding reported values for particles generated from conventional polyethylene. This increase in particle number and elongation may lead to early osteolysis in total hip arthroplasty with Hylamer. (c) 2007 Wiley Periodicals, Inc.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 15 条
  • [1] Precision of peri-prosthetic BMD measurement following cemented total hip arthroplasty
    Downing, MR
    Wilkinson, SJ
    Reid, DM
    Wood, GC
    Ashcroft, GP
    [J]. OSTEOPOROSIS INTERNATIONAL, 2000, 11 : 41 - 41
  • [2] SIZE OF METALLIC AND POLYETHYLENE DEBRIS PARTICLES IN FAILED CEMENTED TOTAL HIP REPLACEMENTS
    LEE, JM
    SALVATI, EA
    BETTS, F
    DICARLO, EF
    DOTY, SB
    BULLOUGH, PG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03): : 380 - 384
  • [3] Expression of CD11c in periprosthetic tissues from failed total hip arthroplasties
    Chamaon, Kathrin
    Barber, Henriette
    Awiszus, Friedemann
    Feuerstein, Bernd
    Lohmann, Christoph H.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2016, 104 (01) : 136 - 144
  • [4] EXPRESSION OF INTEGRIN CD11C IN PERIPROSTHETIC TISSUES FROM FAILED TOTAL HIP ARTHROPLASTIES AND ITS REGULATION BY WEAR PARTICLES IN CELL CULTURE
    Chamaon, K.
    Awiszus, F.
    Lohmann, C. H.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2016, 24 : S334 - S334
  • [5] Wear particle analysis of highly crosslinked polyethylene isolated from a failed total hip arthroplasty
    Minoda, Yukihide
    Kobayashi, Akio
    Sakawa, Akira
    Aihara, Masaharu
    Tada, Koichi
    Sugama, Ryo
    Iwakiri, Kentaro
    Ohashi, Hirotsugu
    Takaoka, Kunio
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 86B (02) : 501 - 505
  • [6] Post-operative peri-prosthetic fracture rates following the use of cemented polished taper-slip stems for primary total hip arthroplasty: a systematic review
    Baryeh, Kwaku
    Sochart, David H.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (12) : 4075 - 4085
  • [7] Post-operative peri-prosthetic fracture rates following the use of cemented polished taper-slip stems for primary total hip arthroplasty: a systematic review
    Kwaku Baryeh
    David H. Sochart
    [J]. Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 4075 - 4085
  • [8] Characteristics of polyethylene wear particles isolated from synovial fluid after mobile-bearing and posterior-stabilized total knee arthroplasties
    Minoda, Y
    Kobayashi, A
    Iwaki, H
    Miyaguchi, M
    Kadoya, Y
    Ohashi, H
    Takaoka, K
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 71B (01) : 1 - 6
  • [9] Migration of polyethylene particles around nonloosened cemented femoral components from a total hip arthroplasty - An autopsy study
    Massin, P
    Chappard, D
    Flautre, B
    Hardouin, P
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 69B (02) : 205 - 215
  • [10] Management of peri-prosthetic joint infection and severe bone loss after total hip arthroplasty using a long-stemmed cemented custom-made articulating spacer (CUMARS)
    Quayle, J.
    Barakat, A.
    Klasan, A.
    Mittal, A.
    Chan, G.
    Gibbs, J.
    Edmondson, M.
    Stott, P.