A nanosilica/exfoliated graphene composite film-modified electrode for sensitive detection of methyl parathion

被引:21
|
作者
Fu, Ju [1 ,2 ]
Tan, Xiao-Hong [2 ]
Li, Yao-Hua [2 ]
Song, Xin-Jian [1 ,2 ]
机构
[1] Hubei Univ Nationalities, Key Lab Biol Resources Protect & Utilizat Hubei P, Enshi 445000, Peoples R China
[2] Hubei Univ Nationalities, Sch Chem & Environm Engn, Enshi 445000, Peoples R China
基金
中国国家自然科学基金;
关键词
Exfoliated graphene; Nanosilica; Modified electrodes; Methyl parathion; Electrochemical sensor; LIQUID-PHASE EXFOLIATION; NANOSHEETS-MODIFIED ELECTRODE; ELECTROCHEMICAL DETERMINATION; ORGANOPHOSPHORUS PESTICIDES; CARBON; OXIDE; NANOPARTICLES; GRAPHITE; SIO2; FUNCTIONALIZATION;
D O I
10.1016/j.cclet.2016.07.007
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Graphene nanosheets (GS) were easily prepared through liquid-phase exfoliation of graphite powder in N,N-dimethylformamide (DMF) with the assistance of sodium citrate. Then, GS was coated onto a glassy carbon electrode (GCE) surface by drop to fabricate a GS/GCE nanointerface. Subsequently, by using tetraethylorthosilicate sol as precursor, nanosilica was electrochemically deposited onto the GS/GCE surface to produce a nanocomposite film electrode (nanosilica/GS/GCE). Electrochemical behaviors of methyl parathion (MP) on the nanosilica/GS/GCE surface were investigated thoroughly. It was found that the nanosilica/GS nanocomposites can improve the redox peak currents of MP significantly due to the synergetic effect. The oxidation peak current was linearly related to MP concentration in the range from 0.0005 mu mol/L to 5.6 mu mol/L. The detection limit was calculated to be 0.07 nmol/L (S/N = 3). The developed method was used to determine MP in real samples. The recoveries were in the range from 95.4% to 104.2%, demonstrating satisfactory results. (C) 2016 Chinese Chemical Society and Institute of Materia Medica, Chinese Academy of Medical Sciences. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1541 / 1546
页数:6
相关论文
共 50 条
  • [1] A nanosilica/exfoliated graphene composite film-modified electrode for sensitive detection of methyl parathion
    Ju Fu
    Xiao-Hong Tan
    Yao-Hua Li
    Xin-Jian Song
    [J]. Chinese Chemical Letters, 2016, 27 (09) : 1541 - 1546
  • [2] Highly Sensitive and Simultaneous Detection of Hydroquinone and Catechol Using Poly(mercaptoacetic acid)/Exfoliated Graphene Composite Film-modified Electrode
    Fu, Ju
    Tan, Xiaohong
    Shi, Zhen
    Song, Xinjian
    Zhang, Shenghui
    [J]. ELECTROANALYSIS, 2016, 28 (01) : 203 - 210
  • [3] Electrochemical determination of methyl parathion using poly(malachite green)/graphene nanosheets–nafion composite film-modified glassy carbon electrode
    Minrong Xu
    Jianying Zhu
    Haichao Su
    Jing Dong
    Shiyun Ai
    Rong Li
    [J]. Journal of Applied Electrochemistry, 2012, 42 : 509 - 516
  • [4] Electrochemical determination of methyl parathion using poly(malachite green)/graphene nanosheets-nafion composite film-modified glassy carbon electrode
    Xu, Minrong
    Zhu, Jianying
    Su, Haichao
    Dong, Jing
    Ai, Shiyun
    Li, Rong
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2012, 42 (07) : 509 - 516
  • [5] Electrochemical Investigation of Methyl Parathion at a Poly-L-cysteine Film-modified Glassy Carbon Electrode
    Wang, Zhengguo
    [J]. CHEMIA ANALITYCZNA, 2009, 54 (03): : 403 - 414
  • [6] AN ELECTRODE MODIFIED WITH AuNPs/GRAPHENE NANOCOMPOSITES FILM FOR THE DETERMINATION OF METHYL PARATHION RESIDUES
    Mao, Yali
    Fa, Huanbao
    Cheng, Yanmei
    Du, Yanqiu
    Yin, Wei
    Hou, Changjun
    Huo, Danqun
    Zhang, Dong
    [J]. NANO, 2014, 9 (08):
  • [7] A methyl parathion electrochemical sensor based on Nano-TiO2, graphene composite film modified electrode
    Song, Bin
    Cao, Wenjie
    Wang, Yazhen
    [J]. FULLERENES NANOTUBES AND CARBON NANOSTRUCTURES, 2016, 24 (07) : 435 - 440
  • [8] Detection of Methyl Parathion at an Electrochemically Reduced Graphene Oxide (ERGO) Modified Electrode
    Jeyapragasam, Tharini
    Saraswathi, Ramiah
    Chen, Shen-Ming
    Lou, Bih-Show
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (11): : 12353 - 12366
  • [9] Detection of formaldehyde by cyclic voltammetry using a PANI/GO composite film-modified electrode
    Wang, Yan-Fang
    Liu, De-Li
    Han, Jia-Jun
    Guo, Ao-Ran
    [J]. IONICS, 2022, 28 (05) : 2457 - 2468
  • [10] Sensitive determination of honokiol using acetylene black film-modified electrode
    Huang, Wensheng
    Zheng, Xiaojiang
    Zhu, Dazhai
    Wu, Kangbing
    [J]. ELECTROCHEMICAL AND SOLID STATE LETTERS, 2008, 11 (09) : F16 - F18