Impact of Adverse Weather Conditions on Outage Statistics of 154 kV Power Transmission System

被引:5
|
作者
Ozdemir, Aydogan [1 ]
Bagriyanik, M. [1 ]
Kaypmaz, A. [2 ]
Gul, O. [1 ]
Ilisu, I. [1 ]
机构
[1] Istanbul Tech Univ, Dept Elect Engn, Istanbul, Turkey
[2] Beykent Univ, Dept Energy Syst Engn, Istanbul, Turkey
关键词
D O I
10.1109/CONIELECOMP.2015.7086954
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Failures in a large electric power system comprising several transmission hardware and substation equipment are inevitable. It is clear that the number of annual failures depends on the system topology itself as well as on the environmental conditions. One of the primary reasons of major transmission line outages are severe weather conditions. The stress created by severe weather is much higher than in normal weather and increases with the severity level of the weather, leading to increases in line outage rates. Thrace part of Turkish National Power System is more important from the point of service reliability as being the most industrialized region of the country. This paper is devoted to the quantitative effects of severe weather on the outage statistics of 154 kV Turkish National Power Transmission system of the region. Moreover, a weather dependent failure rate model was proposed for that part of the system.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 50 条
  • [1] Analysis of Weather and Climate Extremes Impact on Power System Outage
    Ren, Huiying
    Hou, Z. Jason
    Ke, Xinda
    Huang, Qiuhua
    Makatov, Yuri
    2021 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2021,
  • [2] An outage rate model and system adequacy assessment based on adverse weather conditions
    Sun, Rongfu
    Cheng, Lin
    Sun, Yuanzhang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2009, 33 (13): : 7 - 12
  • [3] Statistics for marine accidents in adverse weather conditions
    Ventikos, N. P.
    Koimtzoglou, A.
    Louzis, K.
    Eliopoulou, E.
    MARITIME TECHNOLOGY AND ENGINEERING, VOLS. 1 & 2, 2015, : 243 - 251
  • [4] A Study on the Modeling of the 154 kV Power System and the Prevention of Reverse Transmission in the Incheon Airport Area
    Kim K.
    Kim I.
    Transactions of the Korean Institute of Electrical Engineers, 2023, 72 (11): : 1502 - 1506
  • [5] Development of a Live-line Insulator Inspection Tool System for 154 kV Power Transmission Lines
    Lee, Jae-Kyung
    Park, Joon-Young
    Cho, Byung-Hak
    Oh, Ki-Yong
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2012, 7 (01) : 23 - 33
  • [6] Impact of transmission line parameters on harmonic transmission coefficients in 1000 kV AC power transmission system
    Liu, Shu-Ming
    Xu, Yong-Hai
    Zhu, Yong-Qiang
    Xiao, Xiang-Ning
    Dianwang Jishu/Power System Technology, 2010, 34 (01): : 11 - 14
  • [7] Novel adaptive distance relay algorithm considering the operation of 154 kV SFCL in Korean power transmission system
    Lee, S.
    Lee, J.
    Song, S.
    Yoon, J.
    Lee, B.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2015, 518 : 134 - 139
  • [8] SIZING A GRAIN DRYING SYSTEM FOR ADVERSE WEATHER CONDITIONS
    ZIAUDDIN, AM
    LIANG, T
    TRANSACTIONS OF THE ASAE, 1986, 29 (05): : 1441 - 1446
  • [9] The impact of adverse weather conditions on urban bus performance measures
    Hofmann, M
    O'Mahony, M
    2005 IEEE Intelligent Transportation Systems Conference (ITSC), 2005, : 431 - 436
  • [10] Quantifying the impact of adverse weather conditions on road network performance
    Snelder, Maaike