Attenuation-based characterization of coronary atherosclerotic plaque: Comparison of dual source and dual energy CT with single-source CT and histopathology

被引:34
|
作者
Henzler, Thomas [1 ]
Porubsky, Stefan [2 ]
Kayed, Hany [1 ]
Harder, Nils [1 ,2 ]
Krissak, U. Radko [1 ]
Meyer, Mathias [1 ]
Sueselbeck, Tim [3 ]
Marx, Alexander [2 ]
Michaely, Henrik [1 ]
Schoepf, U. Joseph [4 ]
Schoenberg, Stefan O. [1 ]
Fink, Christian [1 ]
机构
[1] Univ Heidelberg, Dept Clin Radiol & Nucl Med, Med Fac Mannheim, Univ Med Ctr Mannheim, D-68167 Mannheim, Germany
[2] Univ Heidelberg, Dept Pathol, Med Fac Mannheim, Univ Med Ctr Mannheim, D-68167 Mannheim, Germany
[3] Univ Heidelberg, Dept Med 1, Med Fac Mannheim, Univ Med Ctr Mannheim, D-68167 Mannheim, Germany
[4] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
关键词
Atherosclerotic plaque imaging; Histopathology; Dual-source computed tomography; Dual energy CT; Cross scatter radiation; 64-SLICE COMPUTED-TOMOGRAPHY; INTRAVASCULAR ULTRASOUND; ARTERY-DISEASE; HEART-RATE; ANGIOGRAPHY; LESIONS; CLASSIFICATION; PHANTOM; SYSTEM;
D O I
10.1016/j.ejrad.2010.07.024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare different CT acquisition techniques regarding for attenuation-based characterization of coronary atherosclerotic plaques using histopathology as the standard of reference. Materials and methods: In a post mortem study 17 human hearts were studied with dual-source CT (DSCT) and dual energy CT (DECT) mode on a DSCT as well as with 16-slice single-source CT (SSCT). At autopsy, atherosclerotic lesions were cut at 5 mu m sections. Histopathologic classification of the plaques according to the American Heart Association (AHA) criteria was performed by two pathologists. Attenuation values of all plaques were measured in DSCT, DECT and SSCT studies, respectively and classified based on attenuation according to modified AHA criteria. Results: 58 coronary plaques were identified at autopsy. Regardless of the CT technique only 52/58 plaques were found at CT (sensitivity = 89.6%). There was no significant difference between the mean attenuation values of different plaque types between DSCT, DECT, and SSCT: type IV: 11 HU/8 HU/19 HU; type Va: 44 HU/45 HU/52 HU; type Vb: 1088 HU/966 HU/1079 HU). The sensitivity for correct classification varied depending on the plaque type (type II = 0%, type III = 0%, type IV = 43%, type Va = 58%, Vb = 97%). Conclusion: Independent of the used acquisition technique, SSCT, DSCT and DECT show similar results for attenuation-based characterization of atherosclerotic coronary plaques. (C) 2010 Published by Elsevier Ireland Ltd.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 50 条
  • [1] Dual-source CT coronary angiography in patients with atrial fibrillation: Comparison with single-source CT
    Wang, Yining
    Zhang, Zhuhua
    Kong, Lingyan
    Song, Lan
    Merges, Reto D.
    Chen, Jiuhong
    Jin, Zhengyu
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 434 - 441
  • [2] Ex vivo evaluation of coronary atherosclerotic plaques: Characterization with dual-source CT in comparison with histopathology
    Leschka, Sebastian
    Seitun, Sara
    Dettmer, Matthias
    Baumueller, Stephan
    Stolzmann, Paul
    Goetti, Robert
    Scheffel, Hans
    Feuchtner, Gudrun
    Wunnicke, Kathrin
    Wildermuth, Simon
    Oehlschlegel, Christian
    Marincek, Borut
    Jochum, Wolfram
    Alkadhi, Hatem
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2010, 4 (05) : 301 - 308
  • [3] Detection, Quantification and Characterization of Coronary Atherosclerotic Plaque by Dual-Source CT - A Comparison to Intravascular Ultrasound
    Cury, Ricardo C.
    Loureiro, Ricardo
    Bezerra, Hiram
    Petranovic, Milena
    Sarwar, Ammar
    Rocha, Jose
    Pflederer, Tobias
    Marwan, Mohamed
    Raffel, Owen C.
    Hoffmann, Udo
    Brady, Thomas
    Jang, Ik-Kyung
    Achenbach, Stephan
    CIRCULATION, 2008, 118 (18) : S845 - S845
  • [4] Comparison of dual- and single-source dual-energy CT in head and neck imaging
    May, Matthias Stefan
    Wiesmueller, Marco
    Heiss, Rafael
    Brand, Michael
    Bruegel, Joscha
    Uder, Michael
    Wuest, Wolfgang
    EUROPEAN RADIOLOGY, 2019, 29 (08) : 4207 - 4214
  • [5] Comparison of dual- and single-source dual-energy CT in head and neck imaging
    Matthias Stefan May
    Marco Wiesmueller
    Rafael Heiss
    Michael Brand
    Joscha Bruegel
    Michael Uder
    Wolfgang Wuest
    European Radiology, 2019, 29 : 4207 - 4214
  • [6] Low-dose dual-energy CT for stone characterization: a systematic comparison of two generations of split-filter single-source and dual-source dual-energy CT
    Nakhostin, Dominik
    Sartoretti, Thomas
    Eberhard, Matthias
    Krauss, Bernhard
    Mueller, Daniel
    Alkadhi, Hatem
    Euler, Andre
    ABDOMINAL RADIOLOGY, 2021, 46 (05) : 2079 - 2089
  • [7] Low-dose dual-energy CT for stone characterization: a systematic comparison of two generations of split-filter single-source and dual-source dual-energy CT
    Dominik Nakhostin
    Thomas Sartoretti
    Matthias Eberhard
    Bernhard Krauss
    Daniel Müller
    Hatem Alkadhi
    André Euler
    Abdominal Radiology, 2021, 46 : 2079 - 2089
  • [8] Comparison of Dual- and Single-Source Dual-Energy CT for Diagnosis of Acute Pulmonary Artery Embolism
    Petritsch, Bernhard
    Pannenbecker, Pauline
    Weng, Andreas Max
    Veldhoen, Simon
    Grunz, Jan-Peter
    Bley, Thorsten Alexander
    Kosmala, Aleksander
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (04): : 427 - 436
  • [9] DUAL ENERGY CT IMPROVES DIFFERENTIATION OF CORONARY ATHEROSCLEROTIC PLAQUE COMPONENTS COMPARED TO CONVENTIONAL SINGLE ENERGY CT
    Obaid, D. R.
    Calvert, P. A.
    Rudd, J. H. F.
    Gopalan, D.
    Bennett, M. R.
    HEART, 2011, 97 : A64 - A65
  • [10] Clinical Implementation of Single-Source, Dual-Energy CT Simulation in Radiotherapy
    Smith, A.
    Hyun, M.
    Zheng, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E148 - E148