Reproducibility and Robustness of a Real-Time Microfluidic Cell Toxicity Assay

被引:27
|
作者
Cooksey, Gregory A. [1 ]
Elliott, John T. [1 ]
Plant, Anne L. [1 ]
机构
[1] NIST, Div Biochem Sci, Gaithersburg, MD 20899 USA
关键词
CULTURE; SYSTEMS;
D O I
10.1021/ac200273f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Numerous opportunities exist to apply microfluidic technology to high-throughput and high-content cell-based assays. However, maximizing the value of microfluidic assays for applications such as drug discovery, screening, or toxicity evaluation will require assurance of within-device repeatability, day-to-day reproducibility, and robustness to variations in conditions that might occur from laboratory to laboratory. This report describes a study of the performance and variability of a cell-based toxicity assay in microfluidic devices made of poly(dimethylsiloxane) (PDMS). The assay involves expression of destabilized green fluorescent protein (GFP) as a reporter of intracellular protein synthesis and degradation. Reduction in cellular GFP due to inhibition of ribosome activity by cycloheximide (CHX) was quantified with real-time quantitative fluorescence imaging. Assay repeatability was measured within a 64-chamber microfluidic device. Assay performance across a range of cell loading densities within a single device was assessed, as was replication of measurements in microfluidic devices prepared on different days. Assay robustness was tested using different fluorescence illumination sources and reservoir-to-device tubing choices. Both microfluidic and larger scale assay conditions showed comparable GFP decay rates upon CHX exposure, but the microfluidic data provided the higher level of confidence.
引用
收藏
页码:3890 / 3896
页数:7
相关论文
共 50 条
  • [1] Poly(methyl methacrylate) Surface Modification for Surfactant-Free Real-Time Toxicity Assay on Droplet Microfluidic Platform
    Ortiz, Raphael
    Chen, Jian Lin
    Stuckey, David C.
    Steele, Terry W. J.
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (15) : 13801 - 13811
  • [2] A microfluidic cell culture platform for real-time cellular imaging
    Chia-Chun Hsieh
    Song-Bin Huang
    Ping-Ching Wu
    Dar-Bin Shieh
    Gwo-Bin Lee
    Biomedical Microdevices, 2009, 11 : 903 - 913
  • [3] A microfluidic cell culture platform for real-time cellular imaging
    Hsieh, Chia-Chun
    Huang, Song-Bin
    Wu, Ping-Ching
    Shieh, Dar-Bin
    Lee, Gwo-Bin
    BIOMEDICAL MICRODEVICES, 2009, 11 (04) : 903 - 913
  • [4] A cell impedance-based real-time in vitro assay to assess the toxicity of amphotericin B formulations
    Menotti, Jean
    Alanio, Alexandre
    Sturny-Leclere, Aude
    Vitry, Sandrine
    Sauvage, Felix
    Barratt, Gillian
    Bretagne, Stephane
    TOXICOLOGY AND APPLIED PHARMACOLOGY, 2017, 334 : 18 - 23
  • [5] Real-time PCR in microfluidic devices
    Becker, Holger
    Hlawatsch, Nadine
    Klemm, Richard
    Moche, Christian
    Hansen-Hagge, Thomas
    Gaertner, Claudia
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS XII, 2014, 8976
  • [6] Real-time monitoring of microfluidic lithography
    Pisignano, D
    Di Benedetto, F
    Persano, L
    Mele, E
    Cingolani, R
    SYNTHETIC METALS, 2005, 153 (1-3) : 325 - 328
  • [7] Real-time measurement of cholesterol secreted by human hepatocytes using a novel microfluidic assay
    Karnik, Sonali
    Lee, Chaeeun
    Cancino, Andrea
    Bhushan, Abhinav
    TECHNOLOGY, 2018, 6 (3-4): : 135 - 141
  • [8] Real-time assay for GPCRs
    Erickson, B
    ANALYTICAL CHEMISTRY, 2006, 78 (01) : 12 - 12
  • [9] Microfluidic Mobility Shift Assay for Real-Time Analysis of Peptide N-Palmitoylation
    Lanyon-Hogg, Thomas
    Patel, Neki V.
    Ritzefeld, Markus
    Boxall, Katherine J.
    Burke, Rosemary
    Blagg, Julian
    Magee, Anthony I.
    Tate, Edward W.
    SLAS DISCOVERY, 2017, 22 (04) : 418 - 424
  • [10] Bayesian modeling of reproducibility and robustness of RNA reverse transcription and quantitative real-time polymerase chain reaction
    Linden, Jere
    Ranta, Jukka
    Pohjanvirta, Raimo
    ANALYTICAL BIOCHEMISTRY, 2012, 428 (01) : 81 - 91