Energy performance of below-grade envelope of an institutional building in cold regions

被引:8
|
作者
Saaly, Maryam [1 ]
Bobko, Kiril [1 ]
Maghoul, Pooneh [1 ]
Kavgic, Miroslava [1 ]
Hollander, Hartmut [1 ]
机构
[1] Univ Manitoba, Dept Civil Engn, 15 Gillson St, Winnipeg, MB R3T 5V6, Canada
来源
JOURNAL OF BUILDING ENGINEERING | 2020年 / 27卷
基金
加拿大自然科学与工程研究理事会;
关键词
Heat loss; Below-grade envelope; Energy performance; Thermal insulation; Freeze-thaw cycles; Foundation soil; HEAT-LOSSES; SYSTEM; SLAB; EFFICIENCY; SOILS; MODEL;
D O I
10.1016/j.jobe.2019.100911
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effects of freeze-thaw cycles on the thermal properties of foundation soils are often neglected in many building energy simulation programs. Consequently, there is a lack of research focused on the energy dissipation through the below-grade enclosure of buildings in cold regions, where freeze-thaw cycles occur in soils. This paper aims to investigate the energy performance of the below-grade envelope of an institutional building in cold regions by considering the effect of pore water phase change on the thermal properties and consequently the heat exchange between the basement structure and the surrounding soils. For this purpose, the energy loss through the below-grade envelope of the building was numerically studied using 3-D and 2-D analyses. Moreover, the importance of a promising insulation system for the basement of the building was investigated in this paper. The results showed that the energy loss through the below-grade enclosure of the building decreased by approximately 60% when the insulation layers were added to the basement walls and floor slab (i.e., a 230 mm thick insulation layer underneath the floor slab and a 125 mm thick insulation layer surrounding the basement walls). Although reduced, the below-grade heat losses were still significant. To mitigate that, an additional horizontal insulation layer was attached to the basement walls, which lowered the heat loss through the basement walls by 23%. In addition, it was concluded that the presence of a layer of backfill materials surrounding the basement walls that was initially designed for drainage purposes, decreased the basement heat loss by 16.5%. Finally, the results of the 3-D analysis were compared to an equivalent 2-D analysis. The results showed that the 2-D model predicted approximately 22% higher heat flux compared to the 3-D model.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Thermal Performance of a Proposed Geothermal Piles System for Re-Harvesting Heat Loss through the Building Below-Grade Enclosure in Cold Regions
    Saaly, M.
    Maghoul, P.
    COLD REGIONS ENGINEERING 2019, 2019, : 457 - 465
  • [2] Integrating Below-Grade Waterproofing into Structural Details for Successful Building Performance: A Case Study
    Bono, Andrea B.
    Bono, Stephen T.
    Concrete International, 2012, 34 (05) : 41 - 45
  • [3] Pushing the building envelope below grade
    Haisley, P.
    Interface (Raleigh, North Carolina), 2001, 19 (10): : 4 - 12
  • [4] Analysis of the building envelope influence to building energy consumption in the cold regions
    Feng, Guohui
    Sha, Shuai
    Xu, Xiaolong
    8TH INTERNATIONAL COLD CLIMATE HVAC CONFERENCE, 2016, 146 : 243 - 249
  • [5] Performance of molded expanded polystyrene (EPS) thermal insulation in below-grade applications
    Whalen, J
    INSULATION MATERIALS: TESTING AND APPLICATIONS, 4TH VOLUME, 2002, 1426 : 366 - 378
  • [6] A Numerical Investigation of the Thermal Performance of a Gabion Building Envelope in Cold Regions with a Mountainous Climate
    Liu, Fang
    Li, Yafei
    Wang, Yushi
    Zhang, Qunli
    Gao, Wei
    Cao, Ying
    APPLIED SCIENCES-BASEL, 2023, 13 (15):
  • [7] Energy and environmental assessment of high-performance building envelope in cold climate
    Aslani, Alireza
    Hachem-Vermette, Caroline
    ENERGY AND BUILDINGS, 2022, 260
  • [8] HYGRO-THERMAL PERFORMANCE OF IMPERFECTLY PROTECTED BELOW-GRADE WALLS WITH INTERIOR INSULATION - SOME TEST RESULTS
    Kasal, Bohumil
    Wolfgang, Brian
    SUSTAINABLE BUILDING AND REFURBISHMENT FOR NEXT GENERATIONS, 2013, : 377 - 380
  • [9] Performance Evaluation of Waterproofing Membrane Systems Subject to the Concrete Joint Load Behavior of Below-Grade Concrete Structures
    Song, Jaeyoung
    Oh, Kyuhwan
    Kim, Byoungil
    Oh, Sangkeun
    APPLIED SCIENCES-BASEL, 2017, 7 (11):
  • [10] Analysis on the Influence of Building Envelope on Building Energy Efficiency in Severe Cold Area
    Zhang, Z. K.
    Ren, J.