Applicability of bacterial endotoxins test to various blood products by the use of endotoxin-specific lysates

被引:11
|
作者
Ochiai, Masaki [1 ]
Yamamoto, Akihiko [2 ]
Naito, Seishiro [1 ]
Maeyama, Jun-ichi [3 ]
Masumi, Atsuko [3 ]
Hamaguchi, Isao [3 ]
Horiuchi, Yoshinobu [2 ]
Yamaguchi, Kazunari [1 ,3 ]
机构
[1] Natl Inst Infect Dis, Div Qual Assurance, Musashimurayama, Tokyo 2080011, Japan
[2] Natl Inst Infect Dis, Dept Bacterial Pathogenesis & Infect Control, Musashimurayama, Tokyo 2080011, Japan
[3] Natl Inst Infect Dis, Dept Safety Res Blood & Biol, Musashimurayama, Tokyo 2080011, Japan
关键词
Endotoxin; Pyrogen; LAL test; Blood products; Quality control; RABBIT PYROGEN TEST; LIMULUS; COAGULATION; PROTEIN; LAL;
D O I
10.1016/j.biologicals.2010.07.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Endotoxin contamination is a serious threat to the safety of parenteral drugs and the rabbit pyrogen test has played a crucial role in controlling this contamination Although the highly sensitive endotoxin test has replaced the pyrogen test for various pharmaceuticals the pyrogen test is still implemented as the control test for most blood products in Japan We examined the applicability of the endotoxin test to blood products for reliable detection and quantification of endotoxin Nineteen types of blood products were tested for interfering factors based on spike/recovery of endotoxin by using 2 types of endotoxin-specific lysate reagents for photometric techniques Interfering effects on the endotoxin test by the products could be eliminated by diluting from 1/2 to 1/16 with the exception of antithrombin III However conventional lysate reagents that also react with non-pyrogenic substances such as (1-3)-beta-D-glucan produced results that were not relevant to endotoxin content or pyrogenicity Our results showed that the endotoxin test would be applicable to most blood products if used with appropriate endotoxin-specific lysate reagents (C) 2010 The International Association for Biologicals Published by Elsevier Ltd All rights reserved
引用
收藏
页码:629 / 636
页数:8
相关论文
共 32 条
  • [1] MEASUREMENT OF ENDOTOXIN IN BLOOD PRODUCTS USING AN ENDOTOXIN-SPECIFIC LIMULUS TEST REAGENT AND ITS RELATION TO PYROGENIC ACTIVITIES IN RABBIT
    FUJIWARA, H
    ISHIDA, S
    SHIMAZAKI, Y
    NAITO, S
    TSUCHIYA, M
    MATSUURA, S
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1990, 110 (05): : 332 - 340
  • [2] Evaluation of the applicability of the bacterial endotoxin test to antibiotic products
    Yamamoto, A
    Ochiai, M
    Fujiwara, H
    Asakawa, S
    Ichinohe, K
    Kataoka, M
    Toyoizumi, H
    Horiuchi, Y
    BIOLOGICALS, 2000, 28 (03) : 155 - 167
  • [3] QUANTITATIVE MEASUREMENT OF ENDOTOXIN IN CANINE PLASMA USING THE NEW ENDOTOXIN-SPECIFIC CHROMOGENIC TEST
    IKEDA, T
    HIRATA, K
    TABUCHI, K
    TAMURA, H
    TANAKA, S
    CIRCULATORY SHOCK, 1987, 23 (04) : 263 - 269
  • [4] MEASUREMENT OF ENDOTOXIN IN CEREBROSPINAL-FLUID FROM NEONATES AND INFANTS USING A NEW ENDOTOXIN-SPECIFIC CHROMOGENIC TEST
    INAGAKI, M
    NAKAJIMA, M
    ANDO, Y
    TAKASHIMA, S
    TAKESHITA, K
    TANAKA, S
    TAMURA, H
    OBAYASHI, T
    CLINICA CHIMICA ACTA, 1988, 175 (03) : 315 - 319
  • [5] Application of a new perchloric acid treatment method to measure endotoxin in both amniotic fluid and cord blood by an endotoxin-specific chromogenic Limulus test in intraamniotic infection
    Suda, H
    Moroi, C
    Inada, K
    Chida, S
    Yoshida, M
    ACTA PAEDIATRICA JAPONICA, 1996, 38 (05): : 444 - 448
  • [6] EVALUATION OF IPM CS IN GRAM-NEGATIVE BACILLUS INFECTIONS - USE OF AN ENDOTOXIN-SPECIFIC ASSAY
    ENDO, S
    INADA, K
    INOUE, Y
    YAMADA, Y
    FUJII, N
    NAGASAWA, T
    KIKUCHI, M
    TAKI, K
    HOSHI, S
    YOSHIDA, M
    CLINICAL THERAPEUTICS, 1990, 12 (04) : 352 - 356
  • [7] The application of the endotoxin test for globulin and other blood products
    Fujiwara, H
    Kira, K
    Asakawa, S
    Naito, S
    Tanaka, S
    Aizawa, M
    Tuchiya, M
    Takaoka, A
    Yamamoto, A
    Ochiai, M
    Horiuchi, Y
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1999, 119 (06): : 451 - 455
  • [8] Experimental application of a synthetic luminescent substrate assay using endotoxin-specific limulus amebocyte lysate to human blood
    Onodera, Chiaki
    Takahashi, Gaku
    Kan, Shigenori
    Shozushima, Tatsuyori
    Matsumoto, Naoya
    Inada, Katsuya
    Endo, Shigeatsu
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2012, 18 (03) : 370 - 377
  • [9] EARLY DIAGNOSIS OF INVASIVE CANDIDIASIS AND FAST EVALUATION OF ANTIFUNGAL THERAPY BY COMBINED USE OF CONVENTIONAL CHROMOGENIC LIMULUS TEST AND NEWLY DEVELOPED ENDOTOXIN-SPECIFIC ASSAY
    IKEGAMI, K
    IKEMURA, K
    SHIBUYA, M
    SUGIMOTO, H
    YOSHIOKA, T
    SUGIMOTO, T
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1987, 27 (07): : 823 - 823
  • [10] THE APPLICATION OF THE LIMULUS TEST TO A CHROMOGENIC SUBSTRATE TO DETECT ENDOTOXINS IN HUMAN-BLOOD PRODUCTS
    MARTEL, F
    ADENOT, N
    DENHAUT, G
    MARTIN, F
    ROBERT, F
    CHATAING, B
    REVUE FRANCAISE DE TRANSFUSION ET IMMUNO-HEMATOLOGIE, 1985, 28 (03): : 237 - 250