Displacement and Strain Measurement up to 1000 °C Using a Hollow Coaxial Cable Fabry-Perot Resonator

被引:1
|
作者
Zhu, Chen [1 ]
Huang, Jie [1 ]
机构
[1] Missouri Univ Sci & Technol, Rolla, MO 65409 USA
来源
关键词
high temperature; displacement; strain; hollow coaxial cable; Fabry-Perot resonator; FIBER; INTERFEROMETER;
D O I
10.1117/12.2518790
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A hollow coaxial cable Fabry-Perot resonator for displacement and strain measurement up to 1000 degrees C is presented here. Inspired by optical fiber Fabry-Perot interferometers, a Fabry-Perot resonator is implemented on a homemade hollow coaxial cable by introducing two highly-reflective reflectors along the cable. By tracking the shift of the amplitude reflection spectrum of the microwave resonator, the displacement and strain can be determined. The displacement measurement experiment showed the sensor could function properly up to 1000 degrees C. The sensor was also employed to measure the thermal strain of a steel plate during the heating process from 100 to 900 degrees C.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Displacement and Strain Measurement up to 1000 °C Using a Hollow Coaxial Cable Fabry-Perot Resonator
    Zhu, Chen
    Chen, Yizheng
    Zhuang, Yiyang
    Huang, Jie
    SENSORS, 2018, 18 (05)
  • [2] A hollow coaxial cable Fabry-Perot resonator for liquid dielectric constant measurement
    Zhu, Chen
    Zhuang, Yiyang
    Chen, Yizheng
    Huang, Jie
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (04):
  • [3] Wide-range displacement sensor based on a hollow coaxial cable Fabry-Perot resonator
    Zhu, Chen
    Huang, Jie
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2018, 2018, 10598
  • [4] A Centimeter-Range Displacement Sensor Based on a Hollow Coaxial Cable Fabry-Perot Resonator
    Zhu, Chen
    Chen, Yizheng
    Zhuang, Yiyang
    Huang, Jie
    IEEE SENSORS JOURNAL, 2018, 18 (11) : 4436 - 4442
  • [5] A Liquid-Level Sensor Based on a Hollow Coaxial Cable Fabry-Perot Resonator With Micrometer Resolution
    Zhu, Chen
    Zhuang, Yiyang
    Chen, Yizheng
    Huang, Jie
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (12) : 2892 - 2897
  • [6] High Quality Factor Coaxial Cable Fabry-Perot Resonator for Sensing Applications
    Ahmed, Mohammed Farhan
    Xue, Ting
    Wu, Bin
    Huang, Jie
    IEEE SENSORS JOURNAL, 2017, 17 (10) : 3052 - 3057
  • [7] Investigation into coaxial cable Fabry-Perot interferometers for strain measurement and crack detection in RC structures
    Jiao, Tong
    Zhou, Zhi
    Xiao, Hai
    MEASUREMENT, 2019, 147
  • [8] A Coaxial Cable Fabry-Perot Interferometer for Sensing Applications
    Huang, Jie
    Wang, Tao
    Hua, Lei
    Fan, Jun
    Xiao, Hai
    Luo, Ming
    SENSORS, 2013, 13 (11): : 15252 - 15260
  • [9] Strain measurement using FBG Fabry-Perot sensor
    Liu Li
    Wu Zhaoxia
    Song Aijuan
    Yan Dongmei
    SEVENTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY: SENSORS AND INSTRUMENTS, COMPUTER SIMULATION, AND ARTIFICIAL INTELLIGENCE, 2008, 7127
  • [10] LOSS MEASUREMENT OF OPTICAL WAVEGUIDES BY USING FABRY-PEROT RESONATOR.
    Schlaak, H.F.
    Sulz, G.
    Zhan, Yuanling
    Guangxue Xuebao/Acta Optica Sinica, 1986, 6 (11): : 1005 - 1011