摘要
The concern for the security of distribution network renders the necessity of developing an advanced N-1 contingency screening method. However, the complexity of network reconfiguration and islanding operation brings tremendous computation burden for the traditional screening approach. To cope with the problem, a novel acceleration strategy is proposed based on an idea of integrating the optimal power flow calculations under every N-1 contingency into a single search tree. To dynamically check the N-1 security criterion during the solving procedure, the model is formulated in a branch-and-cut framework. At each incumbent solution node, if the load shedding can be resolved by network reconfiguration or islanding operation, a specialized lazy constraint callback approach is implemented to eliminate the current N-1 contingency from the contingency set. Thus, all the calculations for the N-1 contingency are incorporated as a whole and performed only once. The superiority and efficiency of the strategy are verified on the IEEE-33 and 69 bus systems. Numerical results indicate that the proposed approach is an order of magnitude faster than the traditional ones.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Robust prequalification process of a distribution system operator considering N-1 contingency
    Jeong, Chang Min
    Kim, Seung Wan
    Park, Jung Sung
    Yoon, Yong Tae
    Moon, Hee Seung
    IET RENEWABLE POWER GENERATION, 2022, 16 (12) : 2694 - 2710
  • [2] Influence of N-1 Contingency in Natural Gas System on Power System
    Qiao, Zheng
    Jia, Lin
    Zhao, Wei
    Guo, Qinglai
    Sun, Hongbin
    Zhang, Peng
    2017 IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2017,
  • [3] Achieving 100x Acceleration for N-1 Contingency Screening With Uncertain Scenarios Using Deep Convolutional Neural Network
    Du, Yan
    Li, Fangxing
    Li, Jiang
    Zheng, Tongxin
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (04) : 3303 - 3305
  • [4] Evaluation of power system reliability levels for (n-1) outage contingency
    Alshammari, Badr M.
    INTERNATIONAL JOURNAL OF ADVANCED AND APPLIED SCIENCES, 2019, 6 (11): : 68 - 74
  • [5] Fast Analysis of N-1 Contingency Screening With Uncertainty Scenarios Based on Deep Learning
    Yang Y.
    Yang Z.
    Yu J.
    Xiang M.
    Yu H.
    Wang H.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (08): : 2716 - 2724
  • [6] Optimal DG Placement for Power System Reliability based on N-1 Contingency Analysis
    Azhar, Noor Aliff Nazmi Bin Noor
    Mohamad, Hasmaini
    Salim, Nur Ashida
    Yasin, Zuhaila Mat
    19TH IEEE STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT (SCORED 2021), 2021, : 174 - 179
  • [7] Location-Allocation of TCSC Devices on a power system considering N-1 contingency
    Ziaee, O.
    Choobineh, F.
    2016 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT), 2016,
  • [8] The Effect of Load Model Composition on N-1 Contingency Ranking
    Retty, Hema
    Thorp, James S.
    Centeno, Virgilio
    2015 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT), 2015,
  • [9] Optimal Protection Coordination for Microgrids Considering N-1 Contingency
    Saleh, Khaled A.
    Zeineldin, Hatem H.
    El-Saadany, Ehab F.
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2017, 13 (05) : 2270 - 2278
  • [10] Hybrid voltage stability assessment (VSA) for N-1 contingency
    Yuan, Haoyu
    Li, Fangxing
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 122 : 65 - 75