In vitro hemodynamic evaluation of a Simon nitinol vena cava filter: Possible explanation of IVC occlusion

被引:28
|
作者
Leask, RL
Johnston, KW
Ojha, M
机构
[1] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON M5S 3G9, Canada
[2] Univ Toronto, Dept Surg, Toronto, ON M5S 3G9, Canada
关键词
embolism; pulmonary; venae cavae; filters;
D O I
10.1016/S1051-0443(07)61486-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the local hemodynamics in the region of the Simon nitinol filter (SNF), used to prevent pulmonary emboli by capturing clot and promoting lysis. MATERIALS AND METHODS: The hemodynamics of the Simon nitinol inferior vena cava (IVC) filter were evaluated under steady flow (Re = 600) in a 20-mm-diameter IVC model. The photochromic dye tracer technique was used to estimate the velocity and wall shear stress. These flow features were determined for the unoccluded and partially occluded (clot volume = 1,500 mm(3)) states of the SNF along its center plane. RESULTS: A region of low velocities developed around the central axis of the filter extending from the leading edge of the central strut to the filter tip. This phenomenon was created by the strong redirection of flow toward the periphery of the filter. With the presence of the clot, these effects were enhanced, causing flow separation and recirculation. In addition, the shear stress on the hip of the clot was about 30 times that of the upstream value, and turbulence developed in the near-downstream region. CONCLUSIONS: The extended region of almost-stagnant flow near the midsection of the umbrella region could lead to organization of thrombus and fibrin mesh network development. The presence of a simulated clot led to a significant increase in the size of the stagnant, thrombus-prone region as well as turbulence, which, overall, may contribute to caval occlusion.
引用
收藏
页码:613 / 618
页数:6
相关论文
共 50 条
  • [1] MIGRATION OF THE SIMON NITINOL VENA-CAVA FILTER TO THE CHEST
    LAPLANTE, JS
    CONTRACTOR, FM
    KIPROFF, PM
    KHOURY, MB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (02) : 385 - 386
  • [2] In vitro assessment of the hemodynamic effects of a partial occlusion in a vena cava filter
    Couch, GG
    Kim, H
    Ojha, M
    JOURNAL OF VASCULAR SURGERY, 1997, 25 (04) : 663 - 672
  • [3] In vitro evaluation of a retrievable low-profile nitinol vena cava filter
    Bruckheimer, E
    Judelman, AG
    Bruckheimer, SD
    Tavori, I
    Naor, G
    Katzen, BT
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (04) : 469 - 474
  • [4] THE SIMON NITINOL INFERIOR VENA-CAVA FILTER - PRELIMINARY EXPERIENCE IN THE UK
    HAWKINS, SP
    ALKUTOUBI, A
    CLINICAL RADIOLOGY, 1992, 46 (06) : 378 - 380
  • [5] Long-term results of the Simon nitinol inferior vena cava filter
    Poletti, PA
    Becker, CD
    Prina, L
    Ruijs, P
    Bounameaux, H
    Didier, D
    Schneider, PA
    Terrier, F
    EUROPEAN RADIOLOGY, 1998, 8 (02) : 289 - 294
  • [6] Aortic pseudoaneurysm after penetration by a Simon nitinol inferior vena cava filter
    Putterman, D
    Niman, D
    Cohen, G
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (04) : 535 - 538
  • [7] Long-term results of the Simon nitinol inferior vena cava filter
    P. A. Poletti
    C. D. Becker
    L. Prina
    P. Ruijs
    H. Bounameaux
    D. Didier
    P. A. Schneider
    F. Terrier
    European Radiology, 1998, 8 : 289 - 294
  • [8] Clinical experience with the antecubital Simon nitinol IVC filter
    Engmann, E
    Asch, MR
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (05) : 774 - 778
  • [9] Simon Nitinol vena cava filter: Five-year clinical and radiographic experience
    Kiproff, PM
    Park, JU
    Blandon, RJ
    Khoury, MB
    Contractor, FM
    RADIOLOGY, 1996, 201 : 287 - 287
  • [10] COMPARATIVE INVITRO EVALUATION OF THE NITINOL INFERIOR VENA-CAVA FILTER
    PALESTRANT, AM
    PRINCE, M
    SIMON, M
    RADIOLOGY, 1982, 145 (02) : 351 - 355