Comparison of cardiac motion fields from tagged and untagged MR images using nonrigid registration

被引:0
|
作者
Chandrashekara, R
Mohiaddin, RH
Rueckert, D
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Comp, Visual Informat Proc Grp, London SW7 2BZ, England
[2] Royal Brompton & Harefield NHS Trust, Cardiovasc Magnet Resonance Unit, London SW3 6NP, England
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents a comparison of the motion fields computed from TrueFISP untagged and SPAMM tagged magnetic resonance (MR) images using a 4D nonrigid registration algorithm that we have developed for cardiac motion tracking [3]. Our results, which were obtained from a group of 7 normal volunteers, indicate that although there is a good correlation between the motion fields computed from the tagged and untagged MR images, some of the twisting motion is not captured in the motion fields derived from the TrueFISP MR images.
引用
收藏
页码:425 / 433
页数:9
相关论文
共 50 条
  • [1] A Comprehensive Cardiac Motion Estimation Framework Using Both Untagged and 3-D Tagged MR Images Based on Nonrigid Registration
    Shi, Wenzhe
    Zhuang, Xiahai
    Wang, Haiyan
    Duckett, Simon
    Luong, Duy V. N.
    Tobon-Gomez, Catalina
    Tung, KaiPin
    Edwards, Philip J.
    Rhode, Kawal S.
    Razavi, Reza S.
    Ourselin, Sebastien
    Rueckert, Daniel
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (06) : 1263 - 1275
  • [2] Simultaneous Reconstruction of 4-D Myocardial Motion from Both Tagged and Untagged MR Images Using Nonrigid Image Registration
    Shi, Wenzhe
    Murgasova, Maria
    Edwards, Philip
    Rueckert, Daniel
    MEDICAL IMAGING AND AUGMENTED REALITY, 2010, 6326 : 98 - 107
  • [3] Analysis of myocardial motion in tagged MR images using nonrigid image registration
    Chandrashekara, R
    Mohiaddin, RH
    Rueckert, D
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 1168 - 1179
  • [4] Analysis of 3-D myocardial motion in tagged MR images using nonrigid image registration
    Chandrashekara, R
    Mohiaddin, RH
    Rueckert, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (10) : 1245 - 1250
  • [5] Cardiac motion tracking in tagged MR images using a 4D B-spline motion model and nonrigid image registration
    Chandrashekara, R
    Mohiaddin, RH
    Rueckert, D
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, 2004, : 468 - 471
  • [6] Unsupervised estimation of myocardial displacement from tagged MR sequences using nonrigid registration
    Ledesma-Carbayo, Maria J.
    Derbyshire, J. Andrew
    Sampath, Smita
    Santos, Andres
    Desco, Manuel
    McVeigh, Elliot R.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (01) : 181 - 189
  • [7] Comparison and evaluation of rigid, affine, and nonrigid registration of breast MR images
    Denton, ERE
    Sonoda, LI
    Rueckert, D
    Rankin, SC
    Hayes, C
    Leach, MO
    Hill, DLG
    Hawkes, DJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (05) : 800 - 805
  • [8] Incompressible Cardiac Motion Estimation of the Left Ventricle Using Tagged MR Images
    Liu, Xiaofeng
    Abd-Elmoniem, Khaled Z.
    Prince, Jerry L.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT II, PROCEEDINGS, 2009, 5762 : 331 - +
  • [9] Spatial transformation of motion and deformation fields using nonrigid registration
    Rao, A
    Chandrashekara, R
    Sanchez-Ortiz, GI
    Mohiaddin, R
    Aljabar, P
    Hajnal, JV
    Puri, BK
    Rueckert, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (09) : 1065 - 1076
  • [10] Left ventricular motion reconstruction from planar tagged MR images:: a comparison
    Declerck, J
    Denney, TS
    Öztürk, C
    O'Dell, W
    McVeigh, ER
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06): : 1611 - 1632