A Magnetic Nanocomposite Modifier for Improved Ultrasensitive Detection of Hexavalent Chromium in Water Samples

被引:1
|
作者
Hojnik, Nusa [1 ]
Plohl, Olivija [2 ]
Finsgar, Matjaz [1 ]
机构
[1] Univ Maribor, Fac Chem & Chem Engn, Lab Analyt Chem & Ind Anal, Smetanova 17, Maribor 2000, Slovenia
[2] Univ Maribor, Fac Mech Engn, Lab Characterizat & Proc Polymers, Smetanova 17, Maribor 2000, Slovenia
关键词
adsorptive stripping voltammetry; trace analysis; Cr(VI) determination; magnetic nanocomposite; diethylenetriaminepentaacetic acid; ADSORPTIVE STRIPPING VOLTAMMETRY; GOLD NANOPARTICLES; FILM ELECTRODE; ELECTROCHEMICAL DETECTION; OPTIMIZATION PROCEDURE; SENSITIVE DETECTION; BISMUTH ELECTRODES; CARBON ELECTRODE; RIVER WATER; IN-SITU;
D O I
10.3390/chemosensors9080189
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, different electrodes were employed for the determination of Cr(VI) by the cathodic square-wave voltammetry (SWV) technique and the square-wave adsorptive stripping voltammetry (SWAdSV) technique in combination with diethylenetriaminepentaacetic acid. Using SWV, a comparison of the analytical performance of the bare glassy carbon electrode (GCE), ex situ electrodes (antimony-film-SbFE, copper-film-CuFE, and bismuth-film-BiFE), and the GCE modified with a new magnetic nanocomposite (MNC) material was performed. First, the MNC material was synthesized, i.e., MNPs@SiO2@Lys, where MNPs stands for magnetic maghemite nanoparticles, coated with a thin amorphous silica (SiO2) layer, which was additionally functionalized with derived lysine (Lys). The crystal structure of the prepared MNCs was confirmed by X-ray powder diffraction (XRD), while the morphology and nano-size of the MNCs were investigated by field emission scanning electron microscopy (FE-SEM) and transmission electron microscopy (TEM), where TEM was additionally used to observe the MNP core and silica layer thickness. The presence of functional groups of the MNCs was investigated by attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and surface analysis was performed by X-ray photoelectron spectroscopy (XPS). The hydrophilicity of the modified electrodes was also tested by static contact angle measurements. Then, MNPs@SiO2@Lys was applied onto the electrodes and used with the SWV and SWAdSV techniques. All electrodes tested with the SWV technique were effective for Cr(VI) trace determination. On the other hand, the SWAdSV technique was required for ultra-trace determination of Cr(VI). Using the SWAdSV technique, it was shown that a combination of ex situ BiFE with the deposited MNPs@SiO2@Lys resulted in excellent analytical performance (LOQ = 0.1 mu g/L, a linear concentration range of 0.2-2.0 mu g/L, significantly higher sensitivity compared to the SWV technique, an RSD representing reproducibility of 9.0%, and an average recovery of 98.5%). The applicability of the latter system was also demonstrated for the analysis of a real sample.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] REDUCTION OF HEXAVALENT CHROMIUM IN WATER SAMPLES ACIDIFIED FOR PRESERVATION
    STOLLENWERK, KG
    GROVE, DB
    [J]. JOURNAL OF ENVIRONMENTAL QUALITY, 1985, 14 (03) : 396 - 399
  • [2] Isotope evidence of hexavalent chromium stability in ground water samples
    Cadkova, Eva
    Chrastny, Vladislav
    [J]. CHEMOSPHERE, 2015, 138 : 74 - 80
  • [3] Rapid ultrasensitive detection of hexavalent chromium in soil and groundwater by a microProbing imaging platform
    Li, Mengna
    Tang, Yuchen
    Zhao, Rumeng
    Gao, Tingjuan
    Zhang, Lizhi
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2022, 433
  • [4] Quantification of Hexavalent Chromium in Surface Water Samples by a Selective Electrochemical Method
    Baig, Jameel Ahmed
    Bhutto, Ashfaque Ali
    Uddin, Siraj
    Kazi, Tasneem Gul
    Khan, Muhammad Irfan
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2018, 101 (02) : 577 - 586
  • [5] Early warning detection of hexavalent chromium in water by "Daphnia Toximeter"
    Di Giacinto, F.
    Girotti, S.
    Berti, M.
    Angioni, S. A.
    Ferri, N.
    [J]. TOXICOLOGY LETTERS, 2010, 196 : S122 - S123
  • [6] Adsorption enrichment integrated with paper-based devices for detection of trace levels of hexavalent chromium in water samples
    Abdellah Muhammed
    Ahmed Hussen
    Takashi Kaneta
    [J]. Analytical Sciences, 2024, 40 : 709 - 717
  • [7] Adsorption enrichment integrated with paper-based devices for detection of trace levels of hexavalent chromium in water samples
    Muhammed, Abdellah
    Hussen, Ahmed
    Kaneta, Takashi
    [J]. ANALYTICAL SCIENCES, 2024, 40 (04) : 709 - 717
  • [8] Synthesis and adsorption studies of quaternized magnetic cellulose nanocomposite as adsorbent for hexavalent chromium removal
    Wanathammapong, Jadenipit
    Witoon, Thongthai
    Kasemwong, Kittiwut
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [9] Inhibition assays of free and immobilized urease for detecting hexavalent chromium in water samples
    Fopase, Rushikesh
    Nayak, Suman
    Mohanta, Monalisha
    Kale, Paresh
    Paramasivan, Balasubramanian
    [J]. 3 BIOTECH, 2019, 9 (04)
  • [10] Inhibition assays of free and immobilized urease for detecting hexavalent chromium in water samples
    Rushikesh Fopase
    Suman Nayak
    Monalisha Mohanta
    Paresh Kale
    Balasubramanian Paramasivan
    [J]. 3 Biotech, 2019, 9