Estimation of Walking Exercise Intensity Using 3-D Acceleration Sensor

被引:11
|
作者
Kurihara, Yosuke [1 ]
Watanabe, Kajiro [2 ]
Yoneyama, Mitsuru [3 ]
机构
[1] Seikei Univ, Dept Comp & Informat Sci, Fac Sci & Technol, Tokyo 1808633, Japan
[2] Hosei Univ, Dept Syst Control Engn, Fac Engn, Tokyo 1848584, Japan
[3] Mitsubishi Chem Grp Sci & Technol Res Ctr Inc, Kanagawa 2278502, Japan
关键词
Accelerometer; exercise intensity; metabolic equivalents (METs); walking;
D O I
10.1109/TSMCC.2011.2130522
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper describes a method to estimate the measure of human energy expenditure referred to as metabolic equivalents (METs). The measure is defined by an index of the amount of energy a person expends through normal daily activities. The average MET values are defined by the type of activity; for example, brisk walking corresponds to 4 METs. The index lists 107 activities and the corresponding MET values. However, to determine the energy consumed in a day, each type of activity and its duration must be noted, which is inconvenient and time consuming. Here, we consider a quantitative method to estimate the METs from the acceleration of waist motion in our activities. We consider a simple physical model of amoving human body, define the power output for an activity, and then relate the maximum oxygen intake rate per minute, which is proportional to the energy expenditure per minute with the power output. Based on these factors, we developed an automatic MET estimator using a 3-D accelerometer. The system was examined during various selected activities, and the validity of the MET estimation method was tested in activities, excluding very intense activities. The exercise intensity for walking at various speeds was estimated with an average error of -0.6 METs.
引用
收藏
页码:495 / 500
页数:6
相关论文
共 50 条
  • [1] Analysis of Human Walking by 3-D Acceleration Sensor and Its Application
    Umemura, Koji
    Tachikawa, Koki
    Kurihara, Yosuke
    Watanabe, Kajiro
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 1664 - 1667
  • [2] Estimation of walking direction estimation using a shoe-mounted acceleration sensor
    1600, Science and Engineering Research Support Society (09):
  • [3] Measurement and analysis of golf swing using 3-D acceleration and gyro sensor
    Shirota, Koji
    Watanabe, Kajiro
    Kurihara, Yousuke
    2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, : 356 - 360
  • [4] Measurement and Analysis of Running Form using 3-D Acceleration and Gyroscopic Sensor
    Asai, Shintaro
    Watanabe, Kajiro
    Kurihara, Yosuke
    2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, : 351 - 355
  • [5] Gait Recognition and Walking Exercise Intensity Estimation
    Lin, Bor-Shing
    Liu, Yu-Ting
    Yu, Chu
    Jan, Gene Eu
    Hsiao, Bo-Tang
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2014, 11 (04) : 3822 - 3844
  • [6] Walking analysis using an acceleration sensor
    Tsuruoka, Yuriko
    Shibasaki, Ryosuke
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4989 - +
  • [7] Human balance estimation using a wireless 3D acceleration sensor network
    Simila, Heidi
    Kaartinen, Jouni
    Lindholm, Mikko
    Saarinen, Ari
    Mahjneh, Ibrahim
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 1322 - +
  • [8] Measurement and analyze of jump shoot motion in basketball using a 3-D acceleration and gyroscopic sensor
    Taniguchi, Atsushi
    Watanabe, Kajiro
    Kurihara, Yousuke
    2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, : 361 - 365
  • [9] FPGA Architecture for 3-D FDTD Acceleration Using OpenCL
    Waidyasooriya, H. M.
    Hariyama, M.
    Ohtera, Y.
    2016 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS), 2016, : 4719 - 4719
  • [10] Walking Pattern Analysis Using an Acceleration Sensor Device
    Hong, Ju-Hee
    Han, Kap-Soo
    Kim, Kyungho
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2017, 12 (01) : 396 - 401