Effect of phase-plate adjustment on retinal image sharpness and visible retinal area on ultrawide field imaging

被引:7
|
作者
Gupta, Aditi [1 ]
El-Rami, Hala [1 ]
Barham, Rasha [1 ]
Fleming, Alan [2 ]
van Hemert, Jano [2 ]
Sun, Jennifer K. [1 ,3 ]
Silva, Paolo S. [1 ,3 ,4 ]
Aiello, Lloyd Paul [1 ,3 ]
机构
[1] Joslin Diabet Ctr, Beetham Eye Inst, Boston, MA 02215 USA
[2] Optos Plc, Dunfermline, Fife, Scotland
[3] Harvard Med Sch, Dept Ophthalmol, Boston, MA 02115 USA
[4] Univ Philippines, Natl Inst Hlth, Philippine Eye Res Inst, Teleophthalmol & Image Reading Ctr, Manila, Philippines
关键词
PERIPHERAL LESIONS; QUANTIFICATION; MANAGEMENT;
D O I
10.1038/s41433-018-0270-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To evaluate changes in image sharpness across ultrawide field (UWF) images and the effect of phase-plate adjustment on image contrast and extent of visible retinal area (VRA). Methods This was a single site evaluation of 200 degrees UWF images acquired with phase-plate adjustment (California, Optos, plc) and without (200TX, Optos, plc). Images were acquired using standardized protocol. VRA was manually outlined on each image and quantified using customized software. Mean image sharpness was evaluated using an automated method within the full VRA of each image and within the peripheral region of the VRA. The VRA and image sharpness were evaluated and compared between the two devices. Results Twenty eyes of 10 healthy volunteers were evaluated. Devices with and without phase-plate adjustment produced a similar extent of VRA. Eye steering increased VRA in devices with and without phase-plate adjustment by 39.3% and 34.3%, respectively. Regardless of gaze direction, mean sharpness of the full VRA was reduced in peripheral area with or without phase-plate adjustment. Compared to images without phase-plate adjustment, use of phase-plate adjustment reduced the loss of peripheral image sharpness in all fields (-4.2 to -26.0%; p < 0.001 all fields). The sharpness of the peripheral area for on-axis images was 61.5% higher with phase-plate adjustment. Conclusions The use of phase-plate adjustment does not alter the extent of VRA. However, for on-axis images the loss of sharpness in the periphery is 4.5-fold less with phase-plate adjustment, potentially reducing the need to steer images and improving lesion detection in these areas.
引用
收藏
页码:587 / 591
页数:5
相关论文
共 47 条
  • [1] Effect of phase-plate adjustment on retinal image sharpness and visible retinal area on ultrawide field imaging
    Aditi Gupta
    Hala El-Rami
    Rasha Barham
    Alan Fleming
    Jano van Hemert
    Jennifer K. Sun
    Paolo S. Silva
    Lloyd Paul Aiello
    Eye, 2019, 33 : 587 - 591
  • [2] Comparison of Retinal Image Sharpness and Visible Retinal Area Between Two Ultrawide Field (UWF) Cameras
    Gupta, Aditi
    El-Rami, Hala
    Barham, Rasha
    Fleming, Alan
    Van Hemert, Jano
    Sun, Jennifer K.
    Silva, Paolo Sandico
    Aiello, Lloyd P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [3] Impact of Visible Retinal Area on Diabetic Retinopathy Severity and Detection of Predominantly Peripheral Lesions when Using Ultrawide Field Imaging
    Silva, Paolo S.
    Cavallerano, Jerry
    Elmasry, Mohamed Ashraf
    Fleming, Alan
    van Hemert, Jano
    Lewis, Drew
    Bhaskar, Vijaya
    Tolson, Ann
    Tolls, Dot
    Sun, Jennifer K.
    Aiello, Lloyd P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [4] The Future of Ultrawide Field Imaging for Diabetic Retinopathy Pondering the Retinal Periphery
    Sun, Jennifer K.
    Aiello, Lloyd Paul
    JAMA OPHTHALMOLOGY, 2016, 134 (03) : 247 - 248
  • [5] Analysis of risk factors for retinal detachment in acute retinal necrosis using ultrawide-field fundus imaging
    Moon, Taegyu
    Kim, Hyun Jee
    Ji, Yongsok
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [6] Ultrawide-field retinal imaging markers for atypical and typical Alzheimer's disease
    Lengyel, Imre
    Csincsik, Lajos
    Quinn, Nicola
    MacGillivray, Tom
    Shakespeare, Timothy
    Crutch, Sebastian
    Peto, Tunde
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [7] Nondiabetic Retinal Findings Using Ultrawide Field Imaging in a Diabetes Ocular Telehealth Program
    Haddad, Nour Maya N.
    Silva, Paolo Sandico
    Cavallerano, Jerry
    Tolls, Dorothy
    Tolson, Ann
    Sun, Jennifer K.
    Aiello, Lloyd M.
    Aiello, Lloyd P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [8] Concordance between ophtalmologists and paramedical professionals in screening for retinal abnormalities with ultrawide field imaging
    Durbant, E.
    Vardi, K.
    Bordet, J.
    Barbe, C.
    Garcia, T.
    Angioi, K.
    Arndt, C.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [9] Optomap ultrawide field imaging identifies additional retinal abnormalities in patients with diabetic retinopathy
    Price, Liam D.
    Au, Stephanie
    Chong, N. Victor
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 527 - 531
  • [10] Comparisons of handheld retinal imaging devices with ultrawide field images for determining diabetic retinopathy severity
    Jacoba, Cris Martin P.
    Salongcay, Recivall P.
    Aquino, Lizzie Anne C.
    Salva, Claude Michael G.
    Saunar, Aileen V.
    Alog, Glenn P.
    Peto, Tunde
    Silva, Paolo S.
    ACTA OPHTHALMOLOGICA, 2023, 101 (06) : 670 - 678