Interchangeability of cardiac output measurements between oesophageal Doppler and pulse contour analysis is dependent on stroke volume

被引:0
|
作者
Lorne, Emmanuel [1 ,2 ]
Fischer, Marc-Olivier [3 ]
机构
[1] Amiens Univ Hosp, Anaesthesiol & Crit Care Dept, Ave Rene Laennec, F-80054 Amiens, France
[2] Jules Verne Univ Picardy, CURS, Res Unit Simplified Care Complex Surg Patients, Chemin Thil, F-80025 Amiens, France
[3] Normandie Univ, UNICAEN, CHU Caen Normandie, Serv Anesthesie Reanimat Med Peri Operatoire, F-14000 Caen, France
关键词
Cardiac output; Interchangeability; Pulse contour; Oesophageal doppler; DIAMETER; AORTA;
D O I
10.1016/j.accpm.2019.01.011
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
引用
收藏
页码:113 / 114
页数:2
相关论文
共 50 条
  • [1] AGREEMENT IN STROKE VOLUME MEASUREMENTS BETWEEN OESOPHAGEAL DOPPLER AND PULSE CONTOUR ANALYSIS DURING FLUID CHALLENGES IN THE PERI-OPERATIVE PERIOD
    Bedair, Rafik
    Sevenoaks, Hannah
    Conway, Daniel
    Nirmalan, Mahesh
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A101 - A101
  • [2] Comparison of cardiac output measured by oesophageal Doppler ultrasonography or pulse pressure contour wave analysis
    Caillard, A.
    Gayat, E.
    Tantot, A.
    Dubreuil, G.
    M'Bakulu, E.
    Madadaki, C.
    Bart, F.
    Bresson, D.
    Froelich, S.
    Mebazaa, A.
    Vallee, F.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 114 (06) : 893 - 900
  • [3] Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis
    Lars Øivind Høiseth
    Ingrid Elise Hoff
    Ove Andreas Hagen
    Svein Aslak Landsverk
    Knut Arvid Kirkebøen
    Journal of Clinical Monitoring and Computing, 2015, 29 : 435 - 441
  • [4] Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis
    Hoiseth, Lars Oivind
    Hoff, Ingrid Elise
    Hagen, Ove Andreas
    Landsverk, Svein Aslak
    Kirkeboen, Knut Arvid
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (04) : 435 - 441
  • [5] Output performance: cardiac output by pulse contour analysis
    Haskins, Steve C.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2011, 21 (04) : 305 - 308
  • [6] ESTIMATION OF STROKE VOLUME AND CARDIAC OUTPUT FROM CENTRAL ARTERIAL PULSE CONTOUR IN POSTOPERATIVE PATIENTS
    KOUCHOUK.NT
    SHEPPARD, LC
    MCDONALD, DA
    KIRKLIN, JW
    CIRCULATION, 1968, 38 (4S6) : V118 - &
  • [7] Pressure Pulse Contour-derived Stroke Volume and Cardiac Output in the Morbidly Obese Patient
    Donald P. Bernstein
    Obesity Surgery, 2008, 18 (8) : 1022 - 1022
  • [8] Pressure Pulse Contour-derived Stroke Volume and Cardiac Output in the Morbidly Obese Patient
    Donald P. Bernstein
    Obesity Surgery, 2008, 18 : 1015 - 1021
  • [9] Pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient
    Bernstein, Donald P.
    OBESITY SURGERY, 2008, 18 (08) : 1015 - 1021
  • [10] Equipment review: New techniques for cardiac output measurement - oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis
    Berton, C
    Cholley, B
    CRITICAL CARE, 2002, 6 (03): : 216 - 221