Development of a laser-powered wireless strain gauge device using a continuous-wave laser and photovoltaic cell

被引:3
|
作者
Choi, Mijin [1 ]
Lee, Jung-Ryul [1 ]
Park, Chan-Yik [2 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Aerosp Engn, 291 Daehak Ro, Daejeon 305338, South Korea
[2] Agcy Def Dev, Daejeon, South Korea
基金
新加坡国家研究基金会;
关键词
laser power transmission; wireless power transmission; wireless strain gauge; structural health monitoring; photovoltaic cell;
D O I
10.1177/1045389X16629570
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Wireless sensors have emerged as a reliable method for structural health monitoring. Wireless sensors should ideally have their own power supply, which is a conventional battery in most cases. However, sensors are often retrieved, and batteries must be replaced because of their finite lifespan. In many applications, wireless sensors must be operated in locations that are difficult to access, and these systems often have a desired operational lifespan that exceeds that of conventional batteries. Given this limitation, research devoted to alternative methods, such as energy harvesting or wireless power transmission of batteries, has rapidly increased. In this article, we investigated potential solutions to this challenge by collecting energy from a laser beam to power a wireless sensor. The proposed laser power transmission system features the capabilities of transmitting power to and rapid switching direction to sensor nodes using a laser mirror positioner. The delivered light is captured by a photovoltaic cell and collected in a storage medium to supply the required power to a wireless strain gauge device. Validation of the proposed technology was performed by static and dynamic strain measurements, and the obtained signals from the wireless strain gauge device were compared with those of the wired data acquisition.
引用
收藏
页码:2333 / 2343
页数:11
相关论文
共 50 条
  • [1] Development of Laser-powered Wireless Ultrasonic Device for Aircraft Structural Health Monitoring
    Choi, Mijin
    Lee, Jung-Ryul
    Park, Chan-Yik
    STRUCTURAL HEALTH MONITORING 2015: SYSTEM RELIABILITY FOR VERIFICATION AND IMPLEMENTATION, VOLS. 1 AND 2, 2015, : 2544 - 2551
  • [2] Development of a laser-powered wireless ultrasonic device for aircraft structural health monitoring
    Choi, Mijin
    Shrestha, Manish Man
    Lee, Jung-Ryul
    Park, Chan-Yik
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2018, 17 (02): : 145 - 155
  • [3] HOLOGRAPHIC RECORDING OF A RETINA USING A CONTINUOUS-WAVE LASER
    CALKINS, JL
    LEONARD, CD
    INVESTIGATIVE OPHTHALMOLOGY, 1970, 9 (07): : 554 - &
  • [4] Micro-Bubble Generation Using Continuous-Wave Laser
    Jian, Aoqun
    Wang, Ning
    Zhang, Xuming
    NEMS/MEMS TECHNOLOGY AND DEVICES, 2011, 254 : 215 - 218
  • [5] Supercontinuum generation using a continuous-wave Raman fiber laser
    González-Herráez, M
    Martín-López, S
    Corredera, P
    Hernanz, ML
    Horche, PR
    OPTICS COMMUNICATIONS, 2003, 226 (1-6) : 323 - 328
  • [6] USING AN ELECTROOPTIC MODULATOR TO STABILIZE THE POWER OF A CONTINUOUS-WAVE LASER
    BIKMUKHAMETOV, KA
    KIRYUNIKOV, KV
    MEASUREMENT TECHNIQUES USSR, 1985, 28 (08): : 719 - 721
  • [7] Terahertz Computed Tomography Using A Continuous-Wave Gas Laser
    Li, Qi
    Li, Yun-Da
    Ding, Sheng-Hui
    Wang, Qi
    JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2012, 33 (05) : 548 - 558
  • [8] Microfluidic flow direction control using continuous-wave laser
    Jian, A. Q.
    Zhang, K.
    Wang, Y.
    Lau, S. P.
    Tsang, Y. H.
    Zhang, X. M.
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 188 : 329 - 334
  • [9] Influence of ITO layer on laser tolerance of liquid crystal device under continuous-wave laser loading
    Wang K.
    Gong H.
    Liu X.
    Tao C.
    Zhao Y.
    Li D.
    Cao Z.
    Zhang D.
    Shao J.
    Optik, 2022, 270
  • [10] Terahertz Computed Tomography Using A Continuous-Wave Gas Laser
    Qi Li
    Yun-Da Li
    Sheng-Hui Ding
    Qi Wang
    Journal of Infrared, Millimeter, and Terahertz Waves, 2012, 33 : 548 - 558