Optical biopsy of breast tissue using differential path-length spectroscopy

被引:63
|
作者
van Veen, RLP
Amelink, A
Menke-Pluymers, M
van der Pol, C
Sterenborg, HJCM
机构
[1] Erasmus Med Ctr Rotterdam, Ctr Opt Diagnost & Therapy, Dept Radiat Oncol, NL-3008 AE Rotterdam, Netherlands
[2] Erasmus Med Ctr Rotterdam, Dept Surg, NL-3008 AE Rotterdam, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 11期
关键词
D O I
10.1088/0031-9155/50/11/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Differential path-length spectroscopy (DPS) was used to determine the local optical properties of breast tissue in vivo. DPS measurements were made on healthy and malignant breast tissue using a fibre-optic needle probe, and were correlated to the histological outcome of core-needle biopsies taken from the same location as the measurements. DPS yields information on the local tissue blood content, the local blood oxygenation, the average micro-vessel diameter, the beta-carotcne concentration and the scatter slope. Our data show that malignant breast tissue is characterized by a significant decrease in tissue oxygenation and a higher blood content compared to normal breast tissue.
引用
收藏
页码:2573 / 2581
页数:9
相关论文
共 50 条
  • [1] In vivo measurement of the local optical properties of tissue by use of differential path-length spectroscopy
    Amelink, A
    Sterenborg, HJCM
    Bard, MPL
    Burgers, SA
    OPTICS LETTERS, 2004, 29 (10) : 1087 - 1089
  • [2] Controlling the optical path length in turbid media using differential path-length spectroscopy: fiber diameter dependence
    Kaspers, O. P.
    Sterenborg, H. J. C. M.
    Amelink, A.
    APPLIED OPTICS, 2008, 47 (03) : 365 - 371
  • [3] Measurement of the local optical properties of turbid media by differential path-length spectroscopy
    Amelink, A
    Sterenborg, HJCM
    APPLIED OPTICS, 2004, 43 (15) : 3048 - 3054
  • [4] Detection of the acupuncture points in Skin by differential path-length spectroscopy
    Han, Yong-Hui
    Yang, Joon-Mo
    Kim, Min-Su
    Soh, Kwang-Sup
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3572 - 3575
  • [5] Optical path-length spectroscopy of wave propagation in random media
    Popescu, G
    Dogariu, A
    OPTICS LETTERS, 1999, 24 (07) : 442 - 444
  • [6] In vivo quantification of photosensitizer concentration using fluorescence differential path-length spectroscopy: influence of photosensitizer formulation and tissue location
    de Visscher, Sebastiaan A. H. J.
    Witjes, Max J. H.
    Kascakova, Slavka
    Sterenborg, Henricus J. C. M.
    Robinson, Dominic J.
    Roodenburg, Jan L. N.
    Amelink, Arjen
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (06)
  • [7] INFLUENCE OF PATH-LENGTH ON REMOTE OPTICAL SENSING OF PROPERTIES OF BIOLOGICAL TISSUE
    NOSSAL, R
    BONNER, RF
    WEISS, GH
    APPLIED OPTICS, 1989, 28 (12): : 2238 - 2244
  • [8] Correction of fluorescence for depth-specific optical and vascular properties using reflectance and differential path-length spectroscopy during PDT
    van Zaane, F.
    Middelburg, T. A.
    de Bruijn, H. S.
    van der Ploeg-van den Heuvel, A.
    de Haas, E. R. M.
    Sterenborg, H. J. C. M.
    Neumann, H. A. M.
    Robinson, D. J.
    12TH WORLD CONGRESS OF THE INTERNATIONAL PHOTODYNAMIC ASSOCIATION: PHOTODYNAMIC THERAPY: BACK TO THE FUTURE, 2009, 7380
  • [9] TEMPERATURE SENSITIVITY OF OPTICAL FIBER PATH-LENGTH
    WILSON, SJ
    OPTICS COMMUNICATIONS, 1989, 71 (06) : 345 - 350
  • [10] Differential path-length spectroscopy: a tool for quantitative assessment of blood oxygen saturation in microvessels
    Amelink, Arjen
    Haringsma, Jelle
    Sterenborg, Henricus J. C. M.
    GASTROINTESTINAL ENDOSCOPY, 2010, 71 (06) : 1100 - 1100