Experimental investigation and feasibility analysis on a capillary radiant heating system based on solar and air source heat pump dual heat source

被引:54
|
作者
Zhao, M. [1 ,2 ]
Gu, Z. L. [1 ]
Kang, W. B. [1 ,2 ]
Liu, X. [1 ]
Zhang, L. Y. [1 ]
Jin, L. W. [1 ]
Zhang, Q. L. [3 ]
机构
[1] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China
[2] China Northwest Architecture Design & Res Inst Co, Xian 710018, Shaanxi, Peoples R China
[3] Beijing Univ Civil Engn & Architecture, Beijing Municipal Key Lab Heating Gas Supply Vent, Beijing 100084, Peoples R China
关键词
Solar energy; Energy saving; Radiant-capillary-terminal; Building heating; Thermal comfort; ENERGY-CONSUMPTION; CHINA; FLOOR; PERFORMANCE;
D O I
10.1016/j.apenergy.2016.02.043
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to sustainable development, solar energy has drawn much attention and been widely applied in buildings. However, the application of solar energy is limited because of its instability, intermittency and low energy density in winter. In order to use low density and instable solar energy source for heating and improve the utilization efficiency of solar energy, a solar phase change thermal storage (SPCTS) heating system using a radiant-capillary-terminal (RCT) to effectively match the low temperature hot water, a phase change thermal storage (PCTS) to store and continuously utilize the solar energy, and an air source heat pump (ASHP) as an alternate energy, was proposed and set up in this research. Series of experiments were conducted to obtain the relation between the solar radiation utilization rate and the heating supply temperatures, and to evaluate the performance of the RCT module and the indoor thermal environment of the system for its practical application in a residential building in the north-western City of Xi'an, China. The results show that energy saving of the solar heating system can be significantly improved by reducing the supplied water temperature, and the supplied water temperature of the RCT would be no more than 35 degrees C. The capillary radiation heating can adopt a lower water temperature and create a good thermal comfort environment as well. These results may lead to the development of designing and distributing the solar energy for building heating during winter. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2094 / 2105
页数:12
相关论文
共 50 条
  • [1] Experimental Investigation on a Solar Air Heat Pump by Heat Source
    Liu, Yin
    Zhou, Guanghui
    Ma, Jing
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 1590 - 1594
  • [2] Experimental investigation on heating performance of solar integrated air source heat pump
    Dong, Xu
    Tian, Qi
    Li, Zhen
    APPLIED THERMAL ENGINEERING, 2017, 123 : 1013 - 1020
  • [3] Experimental investigation on the heating and cooling performance of a solar air composite heat source heat pump
    Zhang, Feng
    Cai, Jingyong
    Ji, Jie
    Han, Kedong
    Ke, Wei
    RENEWABLE ENERGY, 2020, 161 (161) : 221 - 229
  • [4] Performance analysis of heat pump based on a new solar air-source heat pump heating system
    Liang, Caihua
    Zhang, Xiaosong
    Zhu, Xia
    Li, Xiuwei
    Journal of Southeast University (English Edition), 2010, 26 (02) : 227 - 231
  • [5] An experimental study on a novel radiant-convective heating system based on air source heat pump
    Dong, Jiankai
    Zhang, Long
    Deng, Shiming
    Yang, Bin
    Huang, Shun
    ENERGY AND BUILDINGS, 2018, 158 : 812 - 821
  • [6] Experimental Investigation of Solar Photovoltaic, Heat coupling Water Source Heat Pump Heating System
    Zhang Hong-chen
    Wang Hong-tao
    Li feng-li
    Zhang li-qing
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 93 - +
  • [7] Experimental evaluation of a capillary heating bed driven by an air source heat pump and solar energy
    Su, Junwei
    Li, Juan
    Luo, Xilian
    Yu, Chuck Wah
    Gu, Zhaolin
    INDOOR AND BUILT ENVIRONMENT, 2020, 29 (10) : 1399 - 1411
  • [8] Experimental performance analysis on solar-water compound source heat pump for radiant floor heating system
    Qu Shilin
    Ma Fei
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [9] Comparative analysis of solar-air dual source heat pump system with different heat source configurations
    Cai, Jingyong
    Zhang, Feng
    Ji, Jie
    RENEWABLE ENERGY, 2020, 150 : 191 - 203
  • [10] Comparative analysis of solar-air dual source heat pump system with different heat source configurations
    Cai, Jingyong
    Zhang, Feng
    Ji, Jie
    Ji, Jie (jijie@ustc.edu.cn), 1600, Elsevier Ltd (150): : 191 - 203