A Novel Device to Exploit the Smartphone Camera for Fundus Photography

被引:69
|
作者
Russo, Andrea [1 ]
Morescalchi, Francesco [1 ]
Costagliola, Ciro [2 ]
Delcassi, Luisa [1 ]
Semeraro, Francesco [1 ]
机构
[1] Univ Brescia, Dept Neurol & Vis Sci, Eye Clin, I-25123 Brescia, Italy
[2] Univ Molise, Dept Hlth Sci, Eye Clin, I-86100 Campobasso, Italy
关键词
D O I
10.1155/2015/823139
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To construct an inexpensive, convenient, and portable attachment for smartphones for the acquisition of still and live retinal images. Methods. A small optical device based on the principle of direct ophthalmoscopy was designed to be magnetically attached to a smartphone. Representative images of normal and pathological fundi were taken with the device. Results. A field-of-view up to similar to 20 degrees was captured at a clinical resolution for each fundus image. The cross-polarization technique adopted in the optical design dramatically diminished corneal Purkinje reflections, making it possible to screen patients even through undilated pupils. Light emission proved to be well within safety limits. Conclusions. This optical attachment is a promising, inexpensive, and valuable alternative to the direct ophthalmoscope, potentially eliminating problems of poor exam skills and inexperienced observer bias. Its portability, together with the wireless connectivity of smartphones, presents a promising platform for screening and telemedicine in nonhospital settings. Translational Relevance. Smartphones have the potential to acquire retinal imaging for a portable ophthalmoscopy.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] A smartphone device for ocular fundus photography in acute hypertension
    Muiesan, M. L.
    Salvetti, M.
    Riviera, M.
    Pintossi, C.
    Bertacchini, F.
    Colonetti, E.
    Paini, A.
    Poli, M.
    Semeraro, F.
    Rosei, E. Agabiti
    Russo, A.
    EUROPEAN HEART JOURNAL, 2016, 37 : 401 - 401
  • [2] OCULAR FUNDUS PHOTOGRAPHY WITH A SMARTPHONE DEVICE IN ACUTE HYPERTENSION
    Muiesan, M. L.
    Riviera, M.
    Pintossi, C.
    Bertacchini, F.
    Colonetti, E.
    Salvetti, M.
    Paini, A.
    Poli, M.
    Semeraro, F.
    Rosei, E. Agabiti
    Russo, A.
    JOURNAL OF HYPERTENSION, 2016, 34 : E106 - E107
  • [3] Ocular fundus photography with a smartphone device in acute hypertension
    Muiesan, M. Lorenza
    Salvetti, Massimo
    Paini, Anna
    Riviera, Michela
    Pintossi, Clara
    Bertacchini, Fabio
    Colonetti, Efrem
    Agabiti-Rosei, Claudia
    Poli, Maurizio
    Semeraro, Francesco
    Agabiti-Rosei, Enrico
    Russo, Andrea
    JOURNAL OF HYPERTENSION, 2017, 35 (08) : 1660 - 1665
  • [4] Smartphone Fundus Photography
    Khanamiri, Hossein Nazari
    Nakatsuka, Austin
    El-Annan, Jaafar
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (125):
  • [5] FUNDUS PHOTOGRAPHY WITHOUT A FUNDUS CAMERA
    BOLDREY, EE
    ARCHIVES OF OPHTHALMOLOGY, 1976, 94 (09) : 1616 - 1617
  • [6] Smartphone fundus photography: a narrative review
    Iqbal, Usama
    INTERNATIONAL JOURNAL OF RETINA AND VITREOUS, 2021, 77 (01)
  • [7] Smartphone fundus photography: a narrative review
    Usama Iqbal
    International Journal of Retina and Vitreous, 7
  • [8] Smartphone Assisted Fundus Fundoscopy/Photography
    Barikian A.
    Haddock L.J.
    Current Ophthalmology Reports, 2018, 6 (1) : 46 - 52
  • [9] A NEW CAMERA FOR STEREOSCOPIC FUNDUS PHOTOGRAPHY
    DONALDSO.DD
    ARCHIVES OF OPHTHALMOLOGY, 1965, 73 (02) : 253 - &
  • [10] A smartphone-based portable fundus camera for retinal photography in infants with suspected nonaccidental trauma
    Solyman, Omar
    Elbid, Amgad A.
    Elborgy, Ebrahim S.
    Abushanab, Mokhtar M., I
    JOURNAL OF AAPOS, 2022, 26 (04): : 214 - 216