Distributed Active Damping for Harmonic Instability Suppression in the Multi-paralleled Grid-connected Inverter System

被引:0
|
作者
Wang, Shunyu [1 ]
Cao, Wu [1 ,2 ]
Liu, Kangli [1 ]
Kang, Haotian [1 ]
Zhao, Jianfeng [1 ]
Shi, Chao [3 ]
Song, Jing [4 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing, Peoples R China
[2] Southeast Univ, Jiangsu Prov Key Lab Smart Grid Technol & Equipme, Nanjing, Peoples R China
[3] China Energy Engn Grp, Jiangsu Power Design Inst Co Ltd, Nanjing, Peoples R China
[4] NR Elect Co Ltd, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
harmonic instability problem; distributed active damping; grid voltage feedforward strategy; second-order lag corrector; global admittance; STABILITY; WEAK; DAMPER;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Aiming at the harmonic instability problem of multi-paralleled grid-connected inverter system, which is caused by the interaction among the fast inner current or voltage control loops of inverters and grid impendence, distributed active damping is proposed in this paper. This approach is based on the grid voltage feedforward strategy and increase the damping of the global admittance (GA), which effectively improves the system stability. One of the advantages of this approach is that when some of the active damping fail to work, the remaining active damping can still maintain the system stability. Another is the employment of a second-order lag corrector which can alleviate the influence of the ignorance the prediction component and improve the characteristic of inverter output admittance at the harmonic controlled frequencies. Simulations are carried out and the results verify the effectiveness of the proposed method.
引用
收藏
页码:1709 / 1714
页数:6
相关论文
共 50 条
  • [1] Harmonic Stability Assessment for Multi-Paralleled, Grid-Connected Inverters
    Yoon, Changwoo
    Wang, Xiongfei
    Da Silva, Filipe Miguel Faria
    Bak, Claus Leth
    Blaabjerg, Frede
    2014 INTERNATIONAL ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2014, : 1098 - 1103
  • [2] Responsibility Division for Harmonic Instability in the Multi-Paralleled Grid-Connected Inverters System Based on Impedance Analysis
    Zeng, Chengbi
    Wu, Xuefeng
    Miao, Hong
    Duan, Haoxiang
    IEEE ACCESS, 2023, 11 : 115450 - 115461
  • [3] Improved Switching Ripple Suppression Strategy for Multi-Paralleled Grid-Connected Inverters System
    Cao, Wu
    Kang, Haotian
    Liu, Kangli
    Wang, Shunyu
    Zhao, Jianfeng
    Ji, Xiaochun
    Zhao, Jun
    2019 10TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE 2019 - ECCE ASIA), 2019,
  • [4] Resonance Features of Multi-paralleled Grid-connected Inverters and its Damping Method
    Chen, Zhiyong
    Luo, An
    Chen, Yandong
    Li, Mingshen
    2014 INTERNATIONAL ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2014, : 120 - 125
  • [5] A New Filter Topology for Multi-Paralleled Grid-Connected Inverters
    Zhou, Hongwei
    Yang, Xu
    Zhang, Jiansong
    2019 IEEE 10TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG 2019), 2019, : 429 - 433
  • [6] Interaction Admittance Based Modeling of Multi-Paralleled Grid-Connected Inverter with LCL-Filter
    Lu, Minghui
    Blaabjerg, Frede
    Wang, Xiongfei
    2016 IEEE 2ND ANNUAL SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2016,
  • [7] Inherent Interaction Analysis for Harmonic Oscillations in the Multi-Paralleled Grid-Connected Inverter System Using a Sum Type Criterion: Global Admittance (GA)
    Cao, Wu
    Wang, Shunyu
    Kang, Haotian
    Liu, Kangli
    Wang, Qingsong
    Zhao, Jianfeng
    IEEE ACCESS, 2020, 8 : 8275 - 8285
  • [8] Resonance suppression for grid-connected multi-inverter based on active damping method
    He G.-F.
    Xu D.-H.
    He, Guo-Feng, 1600, Editorial Department of Electric Machines and Control (21): : 62 - 68
  • [9] Modeling and design of a multivariable control system for multi-paralleled grid-connected inverters with LCL filter
    Akhavan, Ali
    Mohammadi, Hamid Reza
    Guerrero, Josep M.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 94 : 354 - 362
  • [10] Stability Analysis of Multi-Paralleled Grid-Connected Inverters with LCL-Filter in the Weak Grid
    Jin, Yinglin
    Fang, Tianzhi
    Shen, Shuheng
    Zhu, Shushu
    45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 3937 - 3942