This study aims to analyze the energy conservation performance of real office space with an energy recovery ventilator (ERV) and to investigate the effect of the arrangement of air supply and exhaust openings. Three types of ventilation systems were chosen for the analysis of coupling computational fluid dynamics (CFD) program with building energy simulation (BES) software. The adoption of mutually complementary boundary conditions for CFD and BES provides more accurate and complete information of air flow distribution and thermal performance in office space. Field measurement was also carried out in a typical office space situated in the middle story of a building to validate the numerical results by measurement data. The office space chosen for this analysis was equipped with air-conditioners on the ceiling with intake of fresh air directly via a heat recovery ventilation system. Its thermal performance and indoor air Row distribution predicted by the coupled method were compared under three types of ventilation system. When the supply and exhaust openings for ERV were arranged on the ceiling, there were no critical differences between the predictions of the CFD-BES coupled method and BES alone on the energy consumption of the HVAC system. On the other hand, discrepancy between the results simulated by the CFD-BES coupled method and BES alone could be clearly found in the case of under-floor-type ventilation system. The discrepancy emphasizes the effectiveness and impact of integrating CFD and BES approaches when non-uniform temperature distribution, that is, thermal stratification, is formed in space. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:57 / 67
页数:11
相关论文
共 50 条
  • [1] Coupled simulation of BES-CFD and performance assessment of energy recovery ventilation system for office model
    T.Hayashi
    K.Ito
    Journal of Central South University, 2012, 19 (03) : 633 - 638
  • [2] Coupled simulation of BES-CFD and performance assessment of energy recovery ventilation system for office model
    Yunqing Fan
    T. Hayashi
    K. Ito
    Journal of Central South University, 2012, 19 : 633 - 638
  • [3] Coupled simulation of BES-CFD and performance assessment of energy recovery ventilation system for office model
    Fan, Yunqing
    Hayashi, T.
    Ito, K.
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2012, 19 (03) : 633 - 638
  • [4] Energy saving through the sun: Analysis of visual comfort and energy consumption in office space
    Tagliabue, Lavinia Chiara
    Buzzetti, Michela
    Arosio, Barbara
    1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 : 693 - 703
  • [5] Analysis of energy consumption and indoor temperature distributions in educational facility based on CFD-BES model
    Hong, Taehoon
    Lee, Myeonghwi
    Kim, Jimin
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 3705 - 3710
  • [6] Heat recovery analysis of a fixed plate energy recovery ventilator
    Moro, Adams
    Kwakye-Boateng, Patricia
    Sustainable Energy Research, 2024, 11 (01)
  • [7] Evaluation and analysis of energy consumption in office buildings
    Maas, Stefan
    Scholzen, Frank
    Thewes, Andreas
    Waldmann, Daniele
    Zuerbes, Arno
    BAUPHYSIK, 2011, 33 (03) : 158 - 166
  • [8] NUMERICAL ANALYSIS OF THE ENERGY CONSUMPTION IN THE OFFICE BUILDING
    Baranowski, Andrzej
    Ferdyn-Grygierek, Joanna
    RYNEK ENERGII, 2011, (02): : 171 - 175
  • [9] Energy consumption analysis on office building ventilation
    Sun, Kechun
    Zhang, Weijun
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 1139 - 1143
  • [10] The effect of energy recovery on perceived air quality, energy consumption, and the economics of an office building
    Fauchoux, Melanie T.
    Simonson, Carey J.
    Torvi, David A.
    ASHRAE TRANSACTIONS 2007 VOL 113, PT 2, 2007, 113 : 436 - 448