The use of a pulsed fibre laser as an excitation source for photoacoustic tomography has been investigated. Fibre lasers have the advantage of being compact, robust and efficient compared to traditional excitation sources used for photoacoustic tomography (e. g. Q-switched Nd:YAG pumped OPO or dye systems). Their high pulse repetition frequencies and adjustable pulse duration, shape and duty cycle also enables a wide range of time and frequency domain excitation methods to be investigated. A 1060nm, 20W fibre laser was used to generate acoustic waves in a tissue mimicking phantom composed of blood filled tubes immersed in a 1% solution of intralipid (mu's=1mm(-1)). The laser was then combined with a Fabry Perot photoacoustic imaging system to obtain 3D images of a tissue mimicking phantom and an in vivo image of the vasculature of the palm of a volunteer. This study has demonstrated that pulsed fibre lasers have potential application as an excitation source for photoacoustic imaging of superficial blood vessels.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] High pulse energy fibre laser as an excitation source for photoacoustic tomography
    Allen, Thomas J.
    Berendt, Martin
    Lin, Di
    Alam, Shaiful U.
    Huynh, Nam T.
    Zhang, Edward
    Richardson, David J.
    Beard, Paul C.
    OPTICS EXPRESS, 2020, 28 (23): : 34255 - 34265
  • [2] Joint imaging with laser-based photoacoustic tomography.
    Chamberland, David L.
    Wang, Xueding
    Carson, Paul
    Fowlkes, Brian
    Roesller, Blake
    Bude, Ron
    ARTHRITIS AND RHEUMATISM, 2006, 54 (12): : 4064 - 4064
  • [3] Low-cost laser scanning photoacoustic microscopy system with a pulsed laser diode excitation source
    Erfanzadeh, Mohsen
    Zhu, Quing
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [4] Novel fibre lasers as excitation sources for photoacoustic tomography and microscopy
    Allen, T. J.
    Berendt, M. O.
    Spurrell, J.
    Alam, S. U.
    Zhang, E. Z.
    Richardson, D. J.
    Beard, P. C.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2016, 2016, 9708
  • [5] Photoacoustic imaging system based on a pulsed laser diode excitation
    Zeng, L. (zenglvming@163.com), 1600, Science Press (40):
  • [6] POSSIBLE USE OF CADMIUM TELLURIDE FOR DETECTION OF PULSED X RAYS IN MEDICAL TOMOGRAPHY.
    Arkad'eva, E.N.
    Karpenko, V.P.
    Maslova, L.V.
    Matveev, O.A.
    Ryvkin, S.M.
    Terent'ev, A.I.
    Soviet physics. Technical physics, 1981, 26 (09): : 1122 - 1125
  • [7] ORBITING TRANSMISSION SOURCE FOR POSITRON TOMOGRAPHY.
    Huesman, R.
    Derenzo, S.E.
    Cahoon, J.L.
    Geyer, A.B.
    Moses, W.W.
    Uber, D.C.
    Vuletich, T.
    Budinger, T.F.
    1600, (35):
  • [8] Portable optical-resolution photoacoustic microscopy with a pulsed laser diode excitation
    Zeng, Lvming
    Liu, Guodong
    Yang, Diwu
    Ji, Xuanrong
    APPLIED PHYSICS LETTERS, 2013, 102 (05)
  • [9] Computed tomography. A great source of radiation exposure
    Raslawski, Elsa C.
    ARCHIVOS ARGENTINOS DE PEDIATRIA, 2008, 106 (03): : 273 - 274
  • [10] Pulsed near-infrared laser diode excitation system for biomedical photoacoustic imaging
    Allen, Thomas J.
    Beard, Paul C.
    OPTICS LETTERS, 2006, 31 (23) : 3462 - 3464