One-minute sit-to-stand test is practical to assess and follow the muscle weakness in cystic fibrosis

被引:6
|
作者
Hardy, Sophie [1 ]
Berardis, Silvia [2 ,3 ]
Aubriot, Anne-Sophie [2 ,3 ]
Reychler, Gregory [1 ,4 ]
Gohy, Sophie [1 ,3 ,4 ]
机构
[1] Clin Univ St Luc, Pneumol Dept, Ave Hippocrate 10, B-1200 Brussels, Belgium
[2] Clin Univ St Luc, Pediat Dept, Brussels, Belgium
[3] Clin Univ St Luc, Cyst Fibrosis Reference Ctr, Brussels, Belgium
[4] Univ Catholique Louvain UCLouvain, Pole Pneumol ENT & Dermatol, Ave Hippocrate 54-B1-54-04, B-1200 Brussels, Belgium
关键词
Cystic fibrosis; Quadriceps strength; Functional exercise capacity; One-minute sit-to-stand test; Intravenous antibiotherapy; PHYSICAL-ACTIVITY; STRENGTH; ADULTS; EXACERBATION; PERFORMANCE; CHILDREN; FORCE;
D O I
10.1186/s12931-022-02176-6
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background Quadriceps muscle weakness and reduced exercise tolerance are prevalent and associated with a worse prognosis in patients with cystic fibrosis (CF). The one-minute sit-to-stand test (1STST) has been proposed to evaluate functional exercise capacity and quadriceps strength. Research question The aim of the study was to verify the relationship between the 1STST and the maximal isometric voluntary contraction of the quadriceps (MVCQ) evaluated by the dynamometer in stable patients with CF and to evaluate the impact of intravenous (IV) antibiotherapy. Methods Dynamometer and 1STST were performed in stable patients with CF at a routine visit, the admission and the discharge of an IV antibiotherapy. Patients wore an activity monitor during 72 h during IV treatment. Results and significance 51 stable patients with CF at a routine visit and 30 treated with IV antibiotherapy were recruited. In stable patients, the 1STST was reduced to a mean of 2101 nxkg (657-SD), representing a median of 79% (7; 142-min; max)) of the predicted values (%PV) as well as the MVCQ to 78.64 N-m (23.21; 170.34), representing 57%PV (26). The 1STST was correlated to MVCQ (r = 0.536; p < 0.0001) and lung function (r = 0.508; p = 0.0001). Over the IV antibiotherapy course, the 1STST improves significantly like lung function and body mass index while a positive trend for MVCQ was observed. The gain of 1STST was correlated to the change in MVCQ (r = 0.441; p = 0.02) and was significantly higher in hospitalized patients versus home therapy. The 1STST is a good alternative to the dynamometer to evaluate and assess muscular weakness for the routine visit and IV antibiotherapy.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] One-minute sit-to-stand test is practical to assess and follow the muscle weakness in cystic fibrosis
    Sophie Hardy
    Silvia Berardis
    Anne-Sophie Aubriot
    Gregory Reychler
    Sophie Gohy
    Respiratory Research, 23
  • [2] One-minute sit-to-stand test as an alternative tool to assess the quadriceps muscle strength in children
    Reychler, G.
    Pincin, L.
    Audag, N.
    Poncin, W.
    Caty, G.
    RESPIRATORY MEDICINE AND RESEARCH, 2020, 78
  • [3] Validity and reliability of the one-minute sit-to-stand test for the measurement of cardio-respiratory responses in children with cystic fibrosis
    Combret, Yann
    Prieur, Guillaume
    Boujibar, Fairuz
    Gravier, Francis-Edouard
    Smondack, Pauline
    Roux, Pascal Le
    Bonnevie, Tristan
    Medrinal, Clement
    Reychler, Gregory
    PULMONOLOGY, 2022, 28 (02): : 137 - 139
  • [4] One-minute sit-to-stand test: Reference values for the Chilean population
    Otto-Yanez, Matias
    Torres-Castro, Rodrigo
    Barros-Poblete, Marisol
    Barros, Marcela
    Valencia, Carola
    Campos, Alex
    Jadue, Leticia
    Puppo, Homero
    Seron, Pamela
    Vilaro, Jordi
    PLOS ONE, 2025, 20 (01):
  • [5] Performance of one-minute sit-to-stand test as a predictor of six-minute walk test results
    Martins Oliveira, Tiago Joao
    Pinto, Paula
    Almeida, Vania
    Carvalho, Raquel
    Fernandes, Maria Jose
    Gomes, Joana
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [6] Measurement properties of the one-minute sit-to-stand test in children and adolescents with cystic fibrosis: A multicenter randomized cross-over trial
    Combret, Yann
    Boujibar, Fairuz
    Gennari, Charlotte
    Medrinal, Clement
    Sicinski, Sophie
    Bonnevie, Tristan
    Gravier, Francis-Edouard
    Laurans, Muriel
    Marguet, Christophe
    Le Roux, Pascal
    Lamia, Bouchra
    Prieur, Guillaume
    Reychler, Gregory
    PLOS ONE, 2021, 16 (02):
  • [7] One-minute sit-to-stand test as a quick functional test for people with COPD in general practice
    Spence, J. G.
    Brincks, J.
    Lokke, A.
    Neustrup, L.
    ostergaard, E. B.
    NPJ PRIMARY CARE RESPIRATORY MEDICINE, 2023, 33 (01)
  • [8] One-minute sit-to-stand test as a quick functional test for people with COPD in general practice
    J. G. Spence
    J. Brincks
    A. Løkke
    L. Neustrup
    E. B. Østergaard
    npj Primary Care Respiratory Medicine, 33
  • [9] The utility and safety of one-minute sit-to-stand test in pulmonary hypertension: A prospective study
    Takeda, Kenichiro
    Shigeta, Ayako
    Inagaki, Takeshi
    Hayama, Nami
    Kawame, Chiaki
    Naraki, Yasuyuki
    Naito, Akira
    Sekine, Ayumi
    Suda, Rika
    Sugiura, Toshihiko
    Tanabe, Nobuhiro
    Suzuki, Takuji
    RESPIRATORY INVESTIGATION, 2025, 63 (01) : 61 - 66
  • [10] The utility and safety of one-minute sit-to-stand test in pulmonary hypertension: a prospective study
    Takeda, Kenichiro
    Shigeta, Ayako
    Inagaki, Takeshi
    Hayama, Nami
    Kawame, Chiaki
    Naraki, Yasuyuki
    Naito, Akira
    Sekine, Ayumi
    Suda, Rika
    Sugiura, Toshihiko
    Suzuki, Takuji
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64