FACTS Devices Allocation for Preventive/Corrective Control Against Voltage Collapse Under Deregulated Power System

被引:0
|
作者
Wibowo, Rony Seto [1 ]
Priyadi, Ardyono [1 ]
Soeprijanto, Adi [1 ]
Yorino, Naoto [2 ]
机构
[1] Inst Teknol Sepuluh Nopember ITS, Surabaya, Indonesia
[2] Hiroshima Univ, Grad Sch Engn, Elect Power & Energy Syst Lab, Hiroshima 730, Japan
关键词
FACTS devices allocation; preventive/corrective control; control coordination; expected security cost; congestion relief; voltage stability; OPTIMAL LOCATION;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
In this paper, an approach for optimal allocation of flexible AC transmission system (FACTS) devices under deregulated power systems is presented. The approach considers system operation under normal and contingency states along with their related probabilities to occur. For each state, FACTS devices are optimally utilized to minimize operating cost. If a contingency occurs, preventive/corrective control strategy is applied to prevent voltage collapse as well as to relieve transmission congestion. During corrective control, fast control action is utilized while during preventive control, both fast and slow control actions are employed. The objective of normal state is to maximize social welfare while the objectives of contingency states are to maximize social welfare and to minimize compensations paid for generations re-scheduling and load shedding. The overall problem is formulated as a mixed integer nonlinear programming problem and is solved using hybrid Particle Swarm Optimization. The effectiveness of the proposed approach is demonstrated on modified IEEE 14 bus test system.
引用
收藏
页码:918 / 922
页数:5
相关论文
共 50 条
  • [1] A critical review on preventive and corrective control against voltage collapse
    Wang, Q
    Ajjarapu, V
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2001, 29 (12) : 1133 - 1144
  • [2] Effect of FACTS Devices on Enhancement of Voltage Stability in a Deregulated Power System
    Rao, V. Sambasiva
    Amarnath, J.
    Rao, V. Purnachandra
    2014 IEEE INTERNATIONAL CONFERENCE ON CIRCUIT, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2014), 2014, : 642 - 650
  • [3] Impact of FACTS Devices in Automatic Generation Control of a Deregulated Power System
    Pandey, Kamlesh
    Sinha, S. K.
    Shrivastava, Ashish
    2016 7TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2016,
  • [4] Location of facts devices on power system for voltage control
    Eminoglu, U
    Alcinoz, T
    Herdem, S
    UPEC 2004: 39th International Universitities Power Engineering Conference, Vols 1-3, Conference Proceedings, 2005, : 338 - 342
  • [5] A comprehensive approach for preventive and corrective control to mitigate voltage collapse
    Feng, ZH
    Ajjarapu, V
    Maratukulam, DJ
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 1423 - 1423
  • [6] A comprehensive approach for preventive and corrective control to mitigate voltage collapse
    Feng, ZH
    Ajjarapu, V
    Maratukulam, DJ
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (02) : 791 - 797
  • [7] Power system emergency control against voltage collapse
    Sutanto, D
    Lachs, WR
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 1501 - 1505
  • [8] A comprehensive approach for FACTS devices optimal allocation to mitigate voltage collapse
    El-Araby, EE
    Yorino, N
    Sasaki, H
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 62 - 67
  • [9] Congestion management in deregulated power system using FACTS devices
    Reddy, Keshi Reddy Saidi
    Padhy, Narayana Prasad
    Patel, R. N.
    2006 IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2006, : 676 - +
  • [10] A new formulation for FACTS allocation for security enhancement against voltage collapse
    Yorino, N
    El-Araby, EE
    Sasaki, H
    Harada, S
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (01) : 3 - 10